Surgical extraction forceps angled at 36°, for lower incisors - Helmut Zepf (12.036.01Z) - Delynov
The Davier chirurgical coudé à 36°, pour incisives inférieures - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.
- Manufacturer: Helmut Zepf Medizintechnik GmbH.
- Reference: 12.036.01Z.
- Reserved for healthcare professionals. Read instructions carefully before use.
What is the Helmut Zepf surgical forceps (12.036.01Z)?
The Helmut Zepf surgical forceps, referenced under code 12.036.01Z, is a specialized manual instrument intended for oral surgery. Its structure is characterized by a working part specifically oriented to grip lower incisors. This medical device, designed by the manufacturer Helmut Zepf Medizintechnik GmbH, is part of the category of reusable consumables and instruments for general practice and oral surgery. Its design is based on ergonomics adapted to the anatomical constraints of the mandible, allowing efficient transmission of forces during luxation and extraction movements.
What are the clinical indications for this angled dental forceps?
This angled dental forceps is exclusively indicated for the extraction of lower incisors. In dental and implant surgery, it is used to perform the avulsion of teeth whose crown is sufficiently preserved to allow a firm grip. The 36° angulation is a major clinical asset for approaching the mandibular anterior sector, offering increased visibility and optimal positioning of the beaks on the tooth neck. It is suitable for simple or complex extraction procedures requiring a reliable instrument for alveolar mobilization before potential implant placement.
What are the technical characteristics of the 12.036.01Z forceps?
On a technical level, this model is distinguished by a precise 36° angulation, optimized for the anatomy of mandibular incisors. Its technical reference 12.036.01Z guarantees precise identification within the Helmut Zepf range. The instrument is designed to withstand the mechanical stresses associated with dental avulsion. The surface finish and the quality of assembly by the manufacturer Helmut Zepf Medizintechnik GmbH ensure a secure grip for the dental surgeon. Although specific material details are not listed, this CONSO category instrument meets the durability requirements for repeated use after sterilization.
What are the contraindications for the use of this instrument?
Contraindications for the use of the Helmut Zepf 12.036.01Z forceps mainly include clinical situations where the anatomy of the tooth or the arch does not match the morphology of the instrument. It must not be used for the extraction of maxillary teeth or mandibular molars, for which forceps with different beaks and angulations are required. Furthermore, its use is contraindicated in cases of extreme bone fragility or roots presenting complex synostoses without prior alveolar preparation. As with any metallic instrument, it is appropriate to check for the absence of known patient allergies to standard components of surgical alloys.
What are the maintenance precautions for this non-absorbable forceps?
As a non-absorbable metallic surgical instrument, the Helmut Zepf forceps requires a rigorous decontamination and sterilization protocol after each intervention. Precautions include manual cleaning or autoclave sterilization according to cycles validated by the manufacturer to eliminate all organic residue. It is imperative to check the integrity of the hinge and the absence of corrosion before each use. Proper maintenance guarantees the longevity of the instrument and maintains the mechanical properties necessary for dental extraction. Compliance with sterilization parameters is crucial to prevent cross-infections in the dental office.
Who is the manufacturer and what standards are respected?
The device is manufactured by Helmut Zepf Medizintechnik GmbH, a recognized manufacturer in the field of high-precision odontological instrumentation. Although the specific regulatory class and CE marking are not detailed in the source documentation, this product is designed according to the German industrial quality standards specific to the Helmut Zepf brand. Healthcare professionals are invited to refer to the instructions for use and the markings present on the original packaging to confirm the regulatory certifications in force. Traceability is ensured by the reference 12.036.01Z affixed to the instrument.
State of the art
Surgical medical consumables play a decisive role in operative safety.
Specifications
| Manufacturer | Helmut Zepf |