Roots - Helmut Zepf (12.051.15Z)
The Roots - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.
- Compliance: Medical device Class I.
- Manufacturer: Helmut Zepf Medizintechnik GmbH.
- Reference: 12.051.15Z.
- Reserved for healthcare professionals. Read instructions carefully before use.
| Manufacturer: Helmut Zepf |
Complete your order
Our customers often order these together
What is the Helmut Zepf Roots forcep?
La pince Roots, référencée sous le code 12.051.15Z, est un instrument chirurgical conçu par Helmut Zepf Medizintechnik GmbH. Fabriquée en acier inoxydable de qualité médicale, cette pince est spécifiquement structurée pour répondre aux exigences de la chirurgie d'extraction. Elle appartient à la catégorie des consommables et des dispositifs de Classe I selon la réglementation en vigueur. Sa composition matérielle assure une compatibilité avec les protocoles de stérilisation standard en chirurgie orale ou en milieu hospitalier. Cet instrument est exclusivement réservé à l'usage des professionnels de santé qualifiés, garantissant une manipulation conforme aux standards cliniques.
What are the clinical indications for this instrument?
Cet instrument Helmut Zepf est destiné à deux indications principales en chirurgie orale. Premièrement, en tant que davier à racines, il est indiqué pour l'extraction de racines naturelles ou de fragments persistants et de débris radiculaires après une fracture coronale. Deuxièmement, il est défini comme un davier d'explantation, spécifiquement destiné à l'ablation de racines artificielles, communément appelées implants. Son application intervient donc lors de phases d'avulsion complexes ou pendant la gestion des échecs implantaires nécessitant le retrait de l'implant.
What are the technical characteristics of reference 12.051.15Z?
The Helmut Zepf Roots forcep (12.051.15Z) is distinguished by its manufacture in medical stainless steel, a material chosen for its resistance to reprocessing cycles. The device is delivered non-sterile and requires complete processing before its first use, including cleaning, disinfection, and sterilization. Due to its robust design and the materials used, the manufacturer Helmut Zepf Medizintechnik GmbH specifies that there is no defined maximum limit for treatment cycles, the lifespan depending on visible wear and the absence of structural damage such as cracks or breaks.
What are the contraindications for the use of this forcep?
The main contraindication related to the use of this medical stainless steel instrument concerns patients with metal intolerance or known hypersensitivity. Contact between the instrument and the patient's tissues can trigger a hypersensitivity reaction. The manufacturer Helmut Zepf emphasizes that if such a reaction occurs during the intervention, the procedure must be immediately stopped and necessary medical measures must be taken. It is therefore imperative to check the patient's allergic history before any surgical handling with this instrument.
What are the maintenance and reprocessing precautions?
All instruments produced by Helmut Zepf Medizintechnik GmbH must undergo a strict cleaning, disinfection, and sterilization protocol before the first use and after each subsequent use. It is crucial to visually inspect the device for any signs of wear, such as cracks, breaks, or defects on the active parts. The use of damaged or worn products is strictly prohibited. Although the material allows for many reprocessing cycles, compatibility with other cleaning products must be verified beforehand to maintain the integrity of the medical stainless steel.
Who is the manufacturer and what standards are respected?
The device is manufactured by Helmut Zepf Medizintechnik GmbH, located in Seitingen-Oberflacht, Germany. This product is classified as a Class I medical device. In accordance with the manufacturer's directives, each instrument must be processed according to the provided safety and usage instructions. The manufacturer insists that these products are intended exclusively for healthcare professionals. Compliance with sterilization protocols and regular inspection of the cutting edges and the overall structure are essential to guarantee the conformity and safety of the device during explantation or radicular extraction procedures.
State of the art
Surgical medical consumables play a decisive role in operative safety.