Extraction Forceps, English Pattern, Fig. 13 - Helmut Zepf (12.213.00Z) - Delynov
The DAVIER. FORME ANGL.. FIG.13 - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.
- Manufacturer: Helmut Zepf Medizintechnik GmbH.
- Reference: 12.213.00Z.
- Reserved for healthcare professionals. Read instructions carefully before use.
What are the Helmut Zepf FIG.13 forceps?
The Helmut Zepf FIG.13 forceps, bearing reference 12.213.00Z, are a manual instrument used in oral surgery for dental extraction. This model adopts a traditional English pattern, characterized by a robust design adapted to the mechanical constraints of exodontia. Manufactured by Helmut Zepf Medizintechnik GmbH, this instrument is intended for the firm grasping of the dental crown. Its structure is designed to effectively transmit the practitioner's force while respecting the integrity of the surrounding tissues during the luxation phases. As a device in the CONSO category at Delynov, it meets the quality requirements of implantology and dental surgery professionals.
What are the clinical indications for these lower premolar forceps?
These lower premolar forceps are specifically indicated for simple or complex avulsion procedures of the first and second premolars of the mandible. In oral surgery, they are used when tooth preservation is no longer possible or as part of orthodontic or pre-implant treatment plans. The geometry of the figure 13 beaks allows for optimal adaptation to the neck of the lower premolars, ensuring a stable grip essential for breaking the ligament attachments. The instrument is used by dental surgeons and stomatologists to perform clean extractions, limiting the risk of root fracture thanks to a homogeneous distribution of pressure on the dental structure.
What are the technical characteristics of model 12.213.00Z?
Model 12.213.00Z is distinguished by its English pattern configuration, a standard in surgical instrumentation for its reliability. These Helmut Zepf forceps are designed with a precise hinge that ensures fluid movement without play during the opening and closing of the beaks. The working part, corresponding to figure 13, is sized to match the standard cervical diameter of mandibular premolars. The finish of the instrument is designed to withstand repeated cleaning and sterilization cycles in an autoclave, thus guaranteeing a longevity in accordance with the standards of the Helmut Zepf Medizintechnik GmbH brand. Its design allows for safe handling, even in a wet environment, offering direct force transmission during the surgical act.
What are the contraindications for the use of this instrument?
Contraindications for the use of the Helmut Zepf FIG.13 forceps are mainly related to clinical situations where manual extraction by forceps is inappropriate. This includes cases of roots presenting significant hypercementosis or severe ankylosis that would require a prior alveolectomy approach. The use of this instrument is also contraindicated if the tooth morphology does not correspond to figure 13 (for example for molars or maxillary teeth), at the risk of causing a crown fracture or soft tissue lesions. It is the practitioner's responsibility to evaluate, by radiological examination, whether the root anatomy allows for safe extraction with this type of lower premolar forceps.
What are the maintenance precautions for this non-resorbable device?
As a reusable and non-resorbable metallic surgical instrument, the Helmut Zepf forceps require a strict decontamination and sterilization protocol after each use. It is imperative to follow the recommendations of the manufacturer Helmut Zepf Medizintechnik GmbH regarding the cleaning solutions used, in order to avoid any corrosion or alteration of the steel. The joints must be checked regularly to ensure the absence of debris and the fluidity of the mechanism. Thorough drying before autoclaving is recommended to maintain the mechanical properties of reference 12.213.00Z. A visual inspection of the beaks before each intervention is necessary to guarantee the absence of deformation or premature wear.
Who is the manufacturer and what standards are respected?
The official manufacturer of this device is Helmut Zepf Medizintechnik GmbH, a recognized manufacturer in the field of high-precision dental instrumentation. Although the regulatory class specifications and CE marking are not explicitly detailed in the current technical sheet, Helmut Zepf products are developed according to rigorous industrial standards specific to surgical medical devices. The reference code 12.213.00Z allows for precise traceability of the product within the Delynov logistics chain. For any specific information regarding certificates of conformity or ISO standards applied to these English pattern forceps, it is recommended to systematically refer to the instructions for use and the technical documentation provided by the manufacturer.
State of the art
Surgical medical consumables play a decisive role in operative safety.
Specifications
| Manufacturer | Helmut Zepf |