English pattern dental extraction forceps, figure 79 - Helmut Zepf (12.279.90Z) - Delynov
The Davier à forme anglaise, figure 79 - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.
- Compliance: Medical device Class I.
- Manufacturer: Helmut Zepf Medizintechnik GmbH.
- Reference: 12.279.90Z.
- Reserved for healthcare professionals. Read instructions carefully before use.
What is the Helmut Zepf English pattern extraction forceps figure 79?
The English pattern extraction forceps, figure 79, referenced under code 12.279.90Z by Helmut Zepf, is a precision manual instrument intended for dental surgery. Manufactured from high-quality medical stainless steel by Helmut Zepf Medizintechnik GmbH, this device is designed to withstand mechanical stress during extraction procedures. Its specific structure meets the requirements of practitioners for interventions in the mandible. As a Class I device, it is delivered non-sterile and requires a complete preparation protocol before its first use. Its robust design ensures optimal force transmission while respecting German manufacturing standards.
What are the clinical indications?
This device is primarily indicated for the extraction of roots and mandibular third molars, commonly referred to as lower wisdom teeth extraction. Its use is reserved for healthcare professionals qualified in oral surgery and implantology. The instrument allows for a firm grip on the dental structure to facilitate luxation and avulsion. It is particularly suited to clinical situations requiring an English pattern approach to access the posterior areas of the lower arch. The manufacturer specifies that the intended purpose is that of a classic manual dental instrument for short-term invasive surgical interventions.
What are the technical characteristics?
The Helmut Zepf 12.279.90Z forceps is distinguished by its medical stainless steel construction, a material chosen for its mechanical properties and corrosion resistance. Figure 79 corresponds to a specific geometry for lower roots and wisdom teeth. The device is classified as Class I according to medical device regulations. It does not have a defined maximum limit of processing cycles (cleaning, disinfection, sterilization) due to the nature of its materials and design, although the user must systematically check for the absence of visible damage such as cracks or breaks before each intervention.
What are the contraindications for use?
The main contraindication mentioned by the manufacturer Helmut Zepf concerns hypersensitivity or metal intolerance. Contact with this medical stainless steel instrument can trigger an allergic reaction in sensitive patients. If such a hypersensitivity reaction occurs during the operative act, the procedure must be stopped immediately and necessary medical measures must be taken. Furthermore, the use of the instrument is strictly prohibited if it shows visible damage, wear, cracks, or defects on the cutting edges, as this could compromise patient safety and the effectiveness of the surgical gesture.
What are the maintenance and sterilization precautions?
Like all instruments from the Helmut Zepf Medizintechnik GmbH brand, these forceps are delivered non-sterile. It is imperative to perform complete cleaning, disinfection, and sterilization before the first use, as well as after each subsequent use. The professional must meticulously inspect the product for any signs of wear or corrosion before use. Reprocessing must follow standard hospital or dental office sterilization protocols. It is crucial never to use damaged products. Compatibility with other instruments used simultaneously during surgery must also be verified beforehand by the practitioner.
Who is the manufacturer and what standards are respected?
The official manufacturer of this device is Helmut Zepf Medizintechnik GmbH, located in Seitingen-Oberflacht, Germany. These forceps are a Class I medical device, complying with regulatory requirements for manual dental instruments. The manufacturer emphasizes that its products are reserved exclusively for healthcare professionals. Traceability and manufacturing quality are ensured by Helmut Zepf's internal processes, guaranteeing a reliable instrument for complex extractions. Compliance with cleaning and sterilization instructions is essential to maintain the device's conformity throughout its operational life in the dental surgery office.
State of the art
Surgical medical consumables play a decisive role in operative safety.
Specifications
| Manufacturer | Helmut Zepf |
| Tags | |
|---|---|
| Tags | |