DENTAL EXTRACTION FORCEPS, AMERICAN PATTERN, FIG. 90, SERRATED HANDLES - Helmut Zepf (14.090.00) - Delynov
The DAVIER, FORME AMÉRICAINE,FIG. 90, MANCHES STRIÉS- Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.
- Manufacturer: Helmut Zepf Medizintechnik GmbH.
- Reference: 14.090.00.
- Reserved for healthcare professionals. Read instructions carefully before use.
| Manufacturer: Helmut Zepf |
Complete your order
Our customers often order these together
What is the American pattern Fig. 90 surgical forceps?
La pince chirurgicale Fig. 90 est un instrument manuel de la marque Helmut Zepf, spécifiquement conçue pour l'extraction chirurgicale orale. Ce modèle adopte le motif américain, caractérisé par une ergonomie spécifique facilitant la manipulation lors des interventions de chirurgie orale. Sa structure comprend des mors adaptés à l'anatomie des molaires supérieures et des manches striés pour optimiser le contrôle du praticien. Fabriqué par Helmut Zepf Medizintechnik GmbH, cet instrument est identifié sous la référence technique 14.090.00. Il constitue une pièce fondamentale pour les cliniciens réalisant des procédures d'exodontie de routine ou complexes en chirurgie orale.
What are the clinical indications for this Helmut Zepf forceps?
Cette pince chirurgicale de type américain est principalement indiquée pour l'avulsion des molaires de l'arcade supérieure. En chirurgie orale et implantologie, elle est utilisée pour effectuer une luxation efficace de l'organe avant son retrait final de l'alvéole. Sa conception permet l'application des forces nécessaires pour rompre les fibres ligamentaires tout en limitant le risque de fracture radiculaire. Le choix de la Fig. 90 répond aux besoins spécifiques des praticiens confrontés à des anatomies radiculaires exigeant une angulation précise des becs pour assurer une prise stable sur le col ou les racines lors des extractions unitaires.
What are the technical characteristics of model 14.090.00?
The Helmut Zepf forceps reference 14.090.00 is distinguished by its American pattern configuration. One of its major features lies in its serrated handles, which provide a surface texture favoring a secure hold, even in the presence of surgical fluids. The working part, corresponding to Fig. 90, is designed to match the morphology of upper molars. The junction between the handles and the beaks is designed to transmit force in a direct and controlled manner. As this instrument does not include a needle, its technical specifications focus on the quality of mechanical fit and the structural resistance necessary for the mechanical stresses of exodontia.
What are the contraindications for the use of this instrument?
Although no specific medical contraindications are listed in the source data for the 14.090.00 forceps, the use of this instrument should be avoided on teeth whose anatomy does not correspond to Fig. 90, such as mandibular teeth or anterior single-cusp teeth, at the risk of causing a fracture. As with any metallic instrument, a contraindication may exist in case of known patient hypersensitivity to the alloy components. The practitioner must ensure that the state of the alveolar bone and the patient's systemic health allow for an extraction procedure. Reference should systematically be made to the instructions for use provided by Helmut Zepf Medizintechnik GmbH.
What are the maintenance and durability precautions?
En tant qu'instrument chirurgical non résorbable et réutilisable, cette pince chirurgicale orale exige un protocole rigoureux de décontamination, de nettoyage et de stérilisation après chaque utilisation pour prévenir les infections croisées. La durabilité de l'instrument Helmut Zepf dépend du respect des cycles de stérilisation recommandés et de l'utilisation de solutions de nettoyage non corrosives. Les manches striés doivent être brossés avec soin pour éliminer tout résidu biologique dans les rainures. Avant chaque intervention, le praticien doit inspecter l'état des mors et de l'articulation pour garantir un fonctionnement mécanique adéquat et l'absence de signes d'usure ou de fatigue du métal.
Who is the manufacturer and what standards are respected?
The official manufacturer of this device is Helmut Zepf Medizintechnik GmbH, a recognized manufacturer in the high-precision surgical instrumentation sector. Although the regulatory class and specific CE marking are not detailed in the present source data, Helmut Zepf products are developed according to rigorous manufacturing standards specific to the German medical industry. To obtain precise information on compliance with the current MDR regulation, ISO certifications, or CE marking, it is imperative to consult the official technical documentation attached to the product or to contact the manufacturer Helmut Zepf directly.
State of the art
Specialized surgical instrumentation is evolving towards ergonomic designs.