Exlog surgical dental extraction forceps for upper incisors and canines, figure 34A - Helmut Zepf (15.034.01) - Delynov
The Davier chirurgical Exlog pour incisives et canines supérieures, figure 34A - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.
- Manufacturer: Helmut Zepf Medizintechnik GmbH.
- Reference: 15.034.01.
- Reserved for healthcare professionals. Read instructions carefully before use.
What is the Exlog 15.034.01 surgical forceps?
The Exlog surgical forceps, bearing reference 15.034.01, is an extraction instrument developed by Helmut Zepf. This specific model belongs to the Exlog range, recognized for its design adapted to the requirements of modern oral surgery. It is dedicated to the avulsion of single-rooted teeth of the upper arch, specifically incisors and canines. Its structure is optimized to transmit the necessary force to the practitioner while respecting the integrity of the surrounding tissues during clinical handling. As an instrument of the Helmut Zepf brand, this device benefits from the expertise of the German manufacturer Helmut Zepf Medizintechnik GmbH in the design of high-precision surgical tools.
What are the clinical indications for this Helmut Zepf forceps?
This figure 34A forceps is indicated for the dental extraction of upper incisors and canines. In oral surgery and implantology, its use occurs during the avulsion phase, whether performed in a context of terminal carious pathology, advanced periodontitis, or in preparation for an implant site. The instrument allows for gripping the tooth at the cervical level to perform the rotational and vestibulo-palatal tilting movements essential for breaking the periodontal ligament. Its configuration is specifically adapted to the anatomy of the anterior teeth of the maxilla, guaranteeing a direct and efficient approach for the dental surgeon during daily interventions in the office or hospital setting.
What are the technical characteristics of the instrument?
The Exlog forceps reference 15.034.01 is distinguished by its morphology known as 'figure 34A'. This nomenclature designates a shape of the beaks and an angulation of the handle specifically studied for upper incisors and canines. The Exlog design by Helmut Zepf emphasizes the balance of the instrument in the hand, allowing for precise force transmission without excessive effort. Although material details are not specified in the source data, this type of surgical instrumentation is traditionally designed to withstand repeated sterilization cycles in an autoclave. The finish and adjustment of the hinges ensure constant fluidity of movement, avoiding any parasitic mechanical play when gripping the dental element to be extracted.
What are the contraindications for the use of this forceps?
The contraindications for the use of the Exlog 15.034.01 forceps are mainly related to clinical situations where extraction with forceps is prohibited or risky. This includes cases of roots presenting significant hypercementosis or severe forms of root dilaceration where an alveolectomy or root separation would be preferable to avoid a bone fracture. Similarly, the use of this instrument on teeth other than upper incisors and canines is strongly discouraged, as the anatomy of the beaks would not correspond to the morphology of premolars or molars, increasing the risk of slipping or fracturing the dental crown. The practitioner must always evaluate the feasibility of the avulsion through prior radiographic examination.
What are the maintenance precautions for this non-resorbable device?
As a reusable metal surgical instrument, the Helmut Zepf forceps requires a rigorous decontamination and sterilization protocol after each use. Although exact cleaning specifications are not listed here, it is customary in dental practices to proceed with pre-disinfection, manual or ultrasonic cleaning, followed by thorough rinsing and drying before autoclaving. The practitioner must ensure that the hinges of the forceps are free of any organic debris to maintain the functionality of the Exlog mechanism. Periodic lubrication of the hinges with products suitable for sterilization may be recommended by the manufacturer to extend the operational life of the instrument.
Who is the manufacturer and what standards are met?
The Exlog surgical forceps (15.034.01) is manufactured by Helmut Zepf Medizintechnik GmbH, a recognized manufacturer in the field of dental and surgical instrumentation. The Helmut Zepf brand is synonymous with German industrial quality. Regarding specific certifications, CE markings, or exact regulatory classes, this information is not detailed in the provided technical documentation. It is the responsibility of the professional user to systematically refer to the instructions for use and the manufacturer's official catalog to verify the compliance of the device with current standards, notably the Medical Device Regulation (MDR). The instrument must be used exclusively by qualified personnel trained in oral surgery techniques.
State of the art
Surgical medical consumables play a decisive role in operative safety.