The Pince à dissection Adson 15 cm avec mors en carbure de tungstène - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.

  • Manufacturer: Helmut Zepf Medizintechnik GmbH.
  • Reference: 22.310.15.
  • Reserved for healthcare professionals. Read instructions carefully before use.

116.19 € 116.19 EUR 119.78 €excl. VAT

119.78 €excl. VAT

Black DaysOnly 9 days left to enjoy it (until Sunday 6 December)

(0.00 € / Units)
  • Manufacturer

This combination does not exist.

Instrument
Manufacturer: Helmut Zepf

Complete your order

Our customers often order these together

In stock Approximal elevator kit for dental surgery, set of 5 instruments - Helmut Zepf (17.007.75) - Delynov Approximal elevator kit for dental surgery, set of 5 instruments - Helmut Zepf (17.007.75) - Delynov
Black Days clearance€152 off!
517.46 € 365.28 €
In stock Cortical bone collector with stopper, diameter 6.0 mm (ABC604L), height 21.94 mm - Osstem - Delynov Cortical bone collector with stopper, diameter 6.0 mm (ABC604L), height 21.94 mm - Osstem - Delynov
Black Days clearance€139 off!
218.46 € 79.20 €
In stock SEMKEN-TAYLOR straight tweezers - Helmut Zepf (22.278.15) - Delynov SEMKEN-TAYLOR straight tweezers - Helmut Zepf (22.278.15) - Delynov
Black Days
46.38 € 44.99 €
Curved Gum Scissors 11.5 cm - Helmut Zepf (46.051.11) - Delynov Curved Gum Scissors 11.5 cm - Helmut Zepf (46.051.11) - Delynov
Black Days clearance
58.68 € 39.12 €
In stock SERAFAST Absorbable Violet Suture 5/0 DS-15 Needle 70cm - Serag & Wiessner - JO103213 SERAFAST Absorbable Violet Suture 5/0 DS-15 Needle 70cm - Serag & Wiessner - JO103213 Recommended suture
Black Days
192.02 € 172.82 €

What is the Helmut Zepf Adson dissecting forceps?

The Adson dissecting forceps designed by Helmut Zepf is a precision surgical instrument intended for soft tissue manipulation. This specific model, referenced under code 22.310.15, is distinguished by the integration of tungsten carbide (TC) jaws. This hybrid structure combines the flexibility of the forceps body with the extreme hardness of the inserts at the tips. Its ergonomic design allows for fine gripping, essential during dissection phases or tissue stabilization before the insertion of a suture needle. It is particularly suitable for oral surgery environments where visibility and control are paramount.

What are the clinical indications for this instrument?

This tungsten carbide adson forceps is indicated for a wide range of procedures in oral, periodontal, and implant surgery. It is mainly used to lift and maintain full-thickness or partial-thickness flaps when exposing surgical sites. In implantology, it facilitates the manipulation of membranes and gingival tissues during the closure of bone graft sites or the placement of healing abutments. Its thinness also allows for intervention in narrow interproximal spaces without damaging adjacent structures, guaranteeing secure tissue maintenance during the steps of approximating wound edges.

What are the technical characteristics of reference 22.310.15?

The Helmut Zepf adson dissecting forceps has a total length of 15 cm, offering optimal leverage and maneuverability for the practitioner. The major technical feature lies in its reinforced tungsten carbide jaws. This material, much harder than standard steel, ensures increased longevity of the gripping surfaces and prevents premature wear of the serrations. This configuration guarantees a firm and constant grip, reducing the risk of tissue laceration due to untimely slipping. The Adson design is characterized by a wide base that tapers towards very narrow tips, allowing precise tactile control and direct transmission of the force exerted by the surgeon's fingers.

What are the contraindications for the use of these forceps?

There are no specific absolute contraindications to the use of these forceps outside of standard oral surgery protocols. However, the use of this instrument on calcified tissues or extremely hard materials (such as metal abutments or crowns) is discouraged, as this could damage the tungsten carbide inserts. Furthermore, as with any surgical instrument, its use is prohibited if the instrument shows signs of corrosion, deformation, or if the jaws are blunt. The practitioner must ensure that the instrument is adapted to the patient's morphology and the specific nature of the planned intervention to avoid any unnecessary tissue trauma.

What are the maintenance precautions for a non-resorbable instrument?

As a reusable metal instrument, the Helmut Zepf Adson dissecting forceps requires a rigorous sterilization protocol after each use. Although the instrument is not a resorbable implantable device, its maintenance directly influences its clinical performance. It is recommended to clean the instrument immediately after the surgical act to prevent protein fixation. Ultrasonic cleaning followed by autoclave sterilization is the standard. Particular attention must be paid to complete drying to prevent any risk of oxidation, especially at the hinge and the tungsten carbide inserts, in order to preserve structural integrity and gripping precision over the long term.

Who is the manufacturer and what standards are respected?

Cet instrument est fabriqué par Helmut Zepf Medizintechnik GmbH, une entreprise reconnue dans le secteur de l'instrumentation chirurgicale pour son expertise technique. Chaque pince est fabriquée selon les standards de qualité élevés spécifiques à la production allemande. Concernant les certifications spécifiques telles que la classe réglementaire ou le marquage CE, ces informations ne sont pas explicitement détaillées dans les données techniques actuelles pour ce modèle 22.310.15. Les praticiens sont invités à se référer systématiquement aux instructions d'utilisation et à l'étiquetage fournis par Helmut Zepf lors de l'acquisition du produit pour confirmer la conformité aux dernières exigences du Règlement sur les Dispositifs Médicaux (MDR).


State of the art

Guided bone regeneration (GBR) in implantology relies on membrane fixation quality.

Delivery

From France to the whole world.

Europe, overseas territories, worldwide. Everything ships through our own logistics.

With you tomorrow

Ordered before 2 pm, delivered within 24 h. Otherwise, within 72 h.

€0 shipping until Sunday 6 December

No minimum, on every order delivered to metropolitan France, Belgium, Luxembourg or Monaco.

A team that answers

Orders, traceability, materiovigilance, your dedicated contact in Épinal. Parcels prepared by the ESAT of Dinozé.

We’ll call you back

References

They trust us.

Public and private healthcare institutions order from Delynov.