Micro-dissection forceps with claws - Helmut Zepf (22.811.17) - Delynov
The Micro-pince à dissection à griffes - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.
- Compliance: Medical device Class I.
- Manufacturer: Helmut Zepf Medizintechnik GmbH.
- Reference: 22.811.17.
- Reserved for healthcare professionals. Read instructions carefully before use.
| Manufacturer: Helmut Zepf |
Complete your order
Our customers often order these together
What is the Helmut Zepf micro tissue forceps with teeth (22.811.17)?
The micro tissue forceps with teeth, referenced under code 22.811.17 by the manufacturer Helmut Zepf Medizintechnik GmbH, is a precision instrument intended for oral surgery. Manufactured from medical stainless steel, this surgical micro forceps is specifically designed to offer a stable grip thanks to its toothed tip. It belongs to the Class I instrument category, ensuring its compliance with regulatory requirements for non-invasive or reusable surgical instrumentation after processing. Its fine structure allows intervention in areas of restricted access, facilitating the practitioner's work during delicate phases of dissection or tissue manipulation.
What are the clinical indications for this surgical micro forceps?
Cette micro-pince à tissus Helmut Zepf avec griffes est indiquée pour la préhension et la manipulation chirurgicale des tissus lors de procédures invasives. Son application principale est en implantologie et parodontologie, notamment durant les protocoles de régénération osseuse guidée (ROG). Au-delà de la manipulation tissulaire, elle est officiellement destinée à la tenue ou au retrait de corps étrangers, et à la manipulation de sutures ou de tampons pendant la chirurgie. Son utilisation est strictement réservée aux professionnels de santé qualifiés, garantissant une manipulation adaptée aux exigences de la micro-chirurgie orale.
What are the technical characteristics of this instrument?
The Helmut Zepf micro forceps (ref. 22.811.17) is distinguished by its high-quality medical stainless steel design. Although delivered non-sterile, it is designed to withstand repeated cycles of cleaning, disinfection, and sterilization without a defined maximum limit of cycles, provided there is no visible damage. The instrument features teeth at its tip to ensure effective prehension. As a Class I device, it meets the manufacturing standards of Helmut Zepf Medizintechnik GmbH. Before each use, it is imperative to check for the absence of cracks, breaks, or defects on the active parts to ensure operative safety.
What are the contraindications for the use of the micro forceps with teeth?
The main contraindication related to the use of this Helmut Zepf instrument is the patient's known hypersensitivity or intolerance to metals, particularly medical stainless steel. A hypersensitivity reaction can be triggered upon contact between the instrument and the tissues. If such a reaction occurs during the procedure, the procedure must be immediately interrupted and necessary medical measures must be taken. It is therefore recommended to validate the absence of metal allergies during the preoperative anamnesis. Furthermore, the use of an instrument showing signs of wear, corrosion, or structural damage is formally prohibited.
What are the maintenance and reprocessing precautions?
Helmut Zepf brand products are delivered non-sterile and must undergo a complete cycle of cleaning, disinfection, and sterilization before the first use, and then after each subsequent use. Reprocessing must follow standard surgical environment protocols. Due to the materials used, there is no predefined limit for treatment cycles, but the longevity of the micro forceps with teeth depends on systematic inspection by the practitioner. Any instrument showing cracks, defective cutting edges, or signs of breakage must be removed from service to avoid any risk of intraoperative complications.
Who is the manufacturer and what standards are respected by this device?
Ce dispositif est fabriqué par Helmut Zepf Medizintechnik GmbH, une entreprise reconnue située à Seitingen-Oberflacht, en Allemagne. Ce produit est classé comme dispositif médical de Classe I selon la réglementation en vigueur. La traçabilité et la qualité de l'acier inoxydable médical utilisé pour la conception de cette micro pince à tissus sont assurées. Le respect des instructions de sécurité et d'utilisation fournies par Helmut Zepf est essentiel pour maintenir la conformité du dispositif lors de son intégration dans le flux chirurgical. L'instrument est spécifiquement dédié à un usage professionnel par des experts du secteur médical et de la chirurgie orale.
State of the art
Guided bone regeneration (GBR) in implantology relies on membrane fixation quality.