Trephine RAL x1 SS - JOTA (229RF.RAL.030) - Delynov
The Trepan RAL X1 SS - JOTA is a medical device manufactured by le fabricant, Class IIa, CE marking CE0483.
- Compliance: Medical device Class IIa, CE marking CE0483.
- Manufacturer: le fabricant.
- Reference: 229RF.RAL.030.
- Reserved for healthcare professionals. Read instructions carefully before use.
| Manufacturer: JOTA Professional Rotary Instruments |
Complete your order
Our customers often order these together
What is the JOTA RAL X1 SS Trepan?
The RAL X1 SS Trepan, bearing the technical reference 229RF.RAL.030, is a high-precision surgical trephine bur manufactured by JOTA AG. This medical device from the JOTA brand is designed for bone surgery interventions requiring a circular cut. It is composed of resistant metallic or plastic materials, suitable for ultrasonic cleaning protocols and specific detergent agents. As a specialized rotary instrument, it allows practitioners to perform bone core sampling or prepare implant sites with high geometric accuracy, while respecting the rigorous reprocessing protocols imposed by the manufacturer.
What are the clinical indications for this sterile trepan drill?
Le trépan stérile RAL X1 SS est indiqué pour les procédures de chirurgie orale et maxillo-faciale impliquant la manipulation des tissus durs. Son utilisation principale concerne le prélèvement d'os autologue sous forme de carottes cylindriques, souvent nécessaires pour les greffes osseuses pré-implantaires. Il est également utilisé pour l'excision tissulaire ou le retrait d'implants lorsque cliniquement requis. Le praticien ou l'expert utilisant le dispositif est seul responsable de la décision d'utiliser ou de réutiliser le produit, évaluant systématiquement l'usure potentielle ou la rupture des instruments dans chaque cas spécifique.
What are the technical characteristics of the 229RF.RAL.030 instrument?
The 229RF.RAL.030 instrument is distinguished by its compatibility with advanced cleaning and sterilization systems. It is designed to resist cleaning agents without foam formation and must be used with sterile demineralized or low-contamination water (maximum 10 germs/ml) to guarantee the absence of endotoxins. The JOTA brand emphasizes that the performance and safety of the device cannot be guaranteed if the instrument shows signs of wear. It is imperative to respect the concentrations, temperatures, and soaking times recommended by the detergent manufacturer to maintain the material integrity of this trepan during its reprocessing cycle.
What are the contraindications for the use of this device?
The use of the trepan is contraindicated in case of visible wear or suspected breakage of the product, as the manufacturer JOTA AG can then no longer guarantee the faulty operation and performance associated with a maximum degree of safety. Another major contraindication lies in the use of cleaning or sterilization procedures not specifically validated for this device. The practitioner must ensure that approved parameters are applied at each cycle and avoid any contamination. In case of doubt regarding the condition of the instrument or the effectiveness of the reprocessing, it is formally recommended to dispose of the product earlier than planned and replace it with a new device.
What are the precautions related to reuse and reprocessing?
JOTA brand products are considered reusable unless otherwise stated on the labeling. However, strict responsibility lies with the practitioner regarding the frequency of reuse based on observed wear. The reprocessing process is critical: all instruments must be cleaned, disinfected, and sterilized before the first use and after each subsequent application. This includes removal from the protective packaging, ultrasonic cleaning with freshly prepared solutions, and sterilization after packaging. Effective cleaning is the sine qua non condition for successful sterilization. It is essential to regularly check that sterilization devices are maintained and monitored.
Who is the manufacturer and what standards are respected?
Le fabricant officiel de cet instrument est JOTA AG, situé Hirschensprungstrasse 2, 9464 Rüthi, Suisse. Le trépan RAL X1 SS est un dispositif médical conforme à la réglementation en vigueur, classé IIa. Il porte le marquage CE0483, garantissant sa conformité aux exigences essentielles de sécurité et de performance de l'Union Européenne. JOTA AG fournit des instructions détaillées pour le retraitement de ses dispositifs, applicables à l'ensemble de sa gamme distribuée. La conformité à ces standards internationaux assure aux praticiens de chirurgie orale et d'implantologie un niveau de sécurité optimal lors de l'utilisation de ces instruments rotatifs en clinique.
State of the art
Surgical medical consumables play a decisive role in operative safety.



















