Rochester-Pean Haemostatic Forceps - Helmut Zepf (23.107.18) - Delynov
The Pince hémostatique de Rochester, modèle Péan - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.
- Manufacturer: Helmut Zepf Medizintechnik GmbH.
- Reference: 23.107.18.
- Reserved for healthcare professionals. Read instructions carefully before use.
| Manufacturer: Helmut Zepf |
Complete your order
Our customers often order these together
What is the Rochester-Pean hemostatic forceps?
La pince Rochester-Pean est un instrument chirurgical métallique conçu par Helmut Zepf Medizintechnik GmbH. Identifiée sous la référence technique 23.107.18, cette pince se caractérise par une structure robuste et des mors dentelés permettant une préhension stable. En chirurgie orale, elle est principalement utilisée comme pince hémostatique chirurgicale pour contrôler les saignements par clampage des vaisseaux ou pour manipuler des tissus denses. Sa conception par Helmut Zepf garantit un ajustement précis des mors, essentiel pour les manœuvres techniques en environnements confinés. Cet instrument fait partie intégrante de l'arsenal pour la régénération osseuse guidée (ROG) et les procédures de chirurgie orale nécessitant une force de maintien constante sans glissement.
What are the clinical indications for this Helmut Zepf instrument?
The use of the Rochester-Pean forceps is indicated in various oral and implant surgery procedures. It is mainly used for immediate hemostasis by compression of severed vessels before their ligation or electrocoagulation. Beyond this primary function, it is employed for grasping and exposing tissue flaps, removing debris or foreign bodies, as well as for holding membranes during GBR protocols. Its versatility makes it a tool of choice for practitioners performing complex extractions or bone reconstruction surgeries. The Rochester model, more robust than Halsted-type forceps, is particularly suitable for thicker tissues encountered in the palatal area or when manipulating dense connective tissues.
What are the technical characteristics of reference 23.107.18?
La référence 23.107.18 désigne un modèle spécifique de pince Rochester-Pean, fabriquée par Helmut Zepf. Ses caractéristiques techniques incluent un système de verrouillage à crémallière multi-positions, permettant de moduler la pression exercée par les mors sur les tissus ou les vaisseaux. La partie active présente des mors striés transversalement sur toute leur longueur, assurant une friction maximale et empêchant le glissement des structures saisies. La longueur et la courbure de l'instrument sont optimisées pour offrir un accès ergonomique aux secteurs postérieurs de la cavité orale. La finition de surface est conçue pour limiter les reflets sous éclairage chirurgical, facilitant ainsi le travail de précision du praticien en chirurgie orale durant les phases critiques de l'intervention.
What are the contraindications for the use of this hemostatic forceps?
There are no specific absolute medical contraindications for the use of the Rochester-Pean forceps, other than those related to the surgical protocols themselves. However, its use should be avoided on fragile structures or nerve tissues that could be damaged by the compression force and the jaw serrations. The instrument must not be used if it shows signs of corrosion, deformation, or if the ratchet mechanism does not engage correctly, as this could compromise patient safety. Practitioners must ensure that the patient does not have hypersensitivity to the metallic components of the instrument. Finally, misuse for manipulating extremely hard materials (such as drills or abutments) could irreversibly damage the jaws.
What are the maintenance precautions for this non-resorbable device?
As a reusable metallic instrument, the Rochester-Pean forceps requires a strict decontamination and sterilization protocol after each use. It is recommended to follow the instructions from the manufacturer Helmut Zepf Medizintechnik GmbH regarding manual or ultrasonic cleaning, drying, and autoclaving. Particular attention must be paid to the hinge and the jaw serrations to eliminate all organic residue. The application of a specific lubricant for surgical instruments on the joint is advised to maintain fluidity of movement and prevent premature wear. Before each procedure, the practitioner must check the perfect alignment of the jaws and the integrity of the ratchet to guarantee effective and secure hemostasis.
Who is the manufacturer and what standards are respected?
Le fabricant officiel de cet instrument est Helmut Zepf Medizintechnik GmbH, une entreprise reconnue dans le secteur de l'instrumentation chirurgicale. Bien que les spécifications réglementaires détaillées telles que la classe exacte ou le marquage CE ne soient pas explicitement mentionnées dans les données techniques fournies pour cette référence 23.107.18, Helmut Zepf est réputé pour produire des dispositifs conformes aux normes de qualité élevées de l'industrie médicale allemande. Pour toute information précise concernant la classe réglementaire (généralement Classe I ou Classe IIa pour ce type d'instrumentation manuelle) ou le certificat de conformité CE, il est impératif de se référer à la notice d'utilisation ou à la documentation technique accompagnant le produit.
State of the art
Guided bone regeneration (GBR) in implantology relies on membrane fixation quality.