Graduated Probe North Carolina CNC - Helmut Zepf (24.454.06TI) - Delynov
The Sonde graduée North Carolina CNC - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.
- Compliance: Medical device Class I.
- Manufacturer: Helmut Zepf Medizintechnik GmbH.
- Reference: 24.454.06TI.
- Reserved for healthcare professionals. Read instructions carefully before use.
What is the North Carolina CNC graduated probe - Helmut Zepf?
The North Carolina CNC graduated probe, referenced under code 24.454.06TI, is a manual diagnostic instrument designed by Helmut Zepf Medizintechnik GmbH. This device is specifically developed for healthcare professionals practicing oral surgery and periodontology. Manufactured from medical stainless steel, this probe features precise markings allowing for direct reading of intra-oral measurements. As a Class I device, it meets the quality requirements for non-invasive or short-term invasive instruments used in dental practices. Its rigid structure and calibrated tip ensure optimal tactile transmission during the exploration of sulci and periodontal pockets.
What are the clinical indications for this instrument?
The intended use of this Helmut Zepf manual instrument is periodontal diagnosis. It is indicated for the millimeter measurement of periodontal pocket depth, the evaluation of the epithelial attachment level, and the detection of gingival recessions. In implant surgery, it can be used to check soft tissue thickness or the depth of drilling sites in a preliminary manner. Its design also allows for the identification of subgingival calculus or root surface irregularities. This instrument is strictly reserved for healthcare professionals trained in periodontal probing and oral diagnostic techniques.
What are the technical characteristics of the 24.454.06TI probe?
The North Carolina CNC probe (reference 24.454.06TI) is distinguished by its precise graduation, produced according to rigorous manufacturing standards. Designed by Helmut Zepf, it utilizes medical stainless steel selected for its corrosion resistance and durability. The instrument is delivered non-sterile and requires a complete protocol of cleaning, disinfection, and sterilization before the first use as well as between each patient. Its ergonomic design is adapted to repeated reprocessing cycles in an autoclave. The manufacturer does not define a maximum limit for processing cycles, as this depends on visible wear, the appearance of cracks, or damage to the edges and markings of the instrument.
What are the contraindications for the use of this probe?
The main medical contraindication mentioned by the manufacturer Helmut Zepf concerns hypersensitivity or intolerance to metals. Contact of the medical stainless steel instrument with an allergic patient can trigger a hypersensitivity reaction. In such a situation, the clinical procedure must be immediately interrupted and necessary medical measures must be taken. It is therefore imperative to check the patient's allergic history before any manipulation. Additionally, the use of the instrument is contraindicated if it shows visible damage such as cracks, breaks, or defects on the active parts, in order to avoid any traumatic risk.
What are the maintenance and sterilization precautions?
Helmut Zepf Medizintechnik GmbH products must follow a strict reprocessing process. Before each use, the instrument must be cleaned, disinfected, and sterilized according to current standards. It is crucial to visually inspect the probe to detect any signs of wear, corrosion, or deformation before use. The use of damaged or worn products is prohibited. Due to the materials used, compatibility with other cleaning and disinfection products must be verified beforehand. Compliance with these safety instructions guarantees not only patient safety but also the longevity of the manual instrumentation within the dental surgery practice.
Who is the manufacturer and what standards are respected?
The official manufacturer of this device is Helmut Zepf Medizintechnik GmbH, located in Seitingen-Oberflacht, Germany. This medical device is classified as Class I according to current regulations. The manufacturer requires that the use of this instrument be exclusively reserved for qualified healthcare professionals. Compliance with medical stainless steel requirements guarantees standard biocompatibility for manual instruments. All handling, from cleaning to sterilization, must follow the instructions provided by Helmut Zepf to ensure the maintenance of the technical performance of the North Carolina CNC graduated probe throughout its operational life.
State of the art
Surgical medical consumables play a decisive role in operative safety.
Specifications
| Manufacturer | Helmut Zepf |
| Tags | |
|---|---|
| Tags | |