Mathieu Needle Holder 17 cm - Helmut Zepf (41.262.17) - Delynov
The Mathieu Porte-Aiguille 17 cm - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.
- Compliance: Medical device Class I.
- Manufacturer: Helmut Zepf Medizintechnik GmbH.
- Reference: 41.262.17.
- Reserved for healthcare professionals. Read instructions carefully before use.
| Manufacturer: Helmut Zepf |
Complete your order
Our customers often order these together
What is the Helmut Zepf Mathieu Needle Holder 17 cm?
The Mathieu Needle Holder 17 cm, referenced under code 41.262.17 by the manufacturer Helmut Zepf Medizintechnik GmbH, is a manual instrument specifically designed for oral surgery. Manufactured from high-quality medical stainless steel, this Class I device belongs to the category of suture instrumentation. Its structure is distinguished by a ratchet system located at the handles, allowing the practitioner to maintain constant pressure on the needle without continuous effort. Its total length of 17 cm provides a lever arm and visibility suitable for both posterior and anterior areas of the oral cavity.
What are the clinical indications?
Ce porte-aiguille Mathieu est indiqué pour toutes les procédures nécessitant une suture des tissus mous en chirurgie orale. Il est principalement utilisé en implantologie, en parodontologie, et pour les extractions simples ou complexes. Son rôle est de sécuriser la préhension de l'aiguille de suture pour permettre un passage précis à travers les berges de la plaie, garantissant ainsi une coaptation tissulaire optimale. En tant qu'instrument chirurgical oral manuel, il est destiné exclusivement à un usage professionnel par les chirurgiens oraux ou implantologues formés aux techniques de suture chirurgicale.
What are the technical characteristics?
The Helmut Zepf needle holder (ref. 41.262.17) features a length of 17 cm, offering an ideal balance between maneuverability and control. It is designed in medical stainless steel, a material chosen for its resistance to repeated sterilization cycles. This Mathieu model is characterized by its internal spring and its multi-step locking system, allowing for modulation of the clamping force on the needle. Unlike Mayo-Hegar type needle holders, the Mathieu model is manipulated in the palm of the hand, which promotes rapid and fluid rotation of the wrist when passing the needle through dense tissues.
What are the contraindications for use?
The main contraindication related to the use of these surgical needle holder forceps concerns known hypersensitivity of the patient to metals. Since the instrument is composed of medical stainless steel, contact may trigger an allergic reaction or intolerance in sensitive subjects. If such a hypersensitivity reaction occurs during the procedure, the manufacturer Helmut Zepf specifies that the procedure must be immediately stopped and necessary medical measures must be taken. Furthermore, the use of the instrument is strictly prohibited if it shows visible damage such as cracks, breaks, or defects on the edges.
What are the maintenance and safety precautions?
Helmut Zepf instruments are delivered non-sterile and must imperatively be cleaned, disinfected, and sterilized before the first use, as well as after each subsequent use. It is crucial to visually inspect the device for any signs of wear, corrosion, or deformation before each procedure. The reprocessing process must be complete to ensure aseptic safety. Due to the robust design and materials used, there is no defined maximum limit for processing cycles, but the user must validate the functionality of the instrument before use. The use of damaged or worn products is formally prohibited.
Who is the manufacturer and what standards are respected?
Ce porte-aiguille est fabriqué par Helmut Zepf Medizintechnik GmbH, une entreprise reconnue située à Seitingen-Oberflacht, en Allemagne. Il s'agit d'un dispositif médical de Classe I, conforme aux réglementations européennes en vigueur pour l'instrumentation manuelle de chirurgie orale. Des protocoles stricts de nettoyage et de stérilisation sont imposés pour maintenir la conformité et la sécurité du produit. En tant que dispositif de Classe I, il répond aux exigences de sécurité et de performance clinique nécessaires à son utilisation en chirurgie orale. La traçabilité est assurée par la référence technique 41.262.17 gravée sur l'instrument.
State of the art
Specialized surgical instrumentation is evolving towards ergonomic designs.