La Grange Gum Scissors 11.5 cm - Helmut Zepf (46.057.11) - Delynov
The LA GRANGE. CISEAUX A GENCIVES. 11.5 CM - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.
- Compliance: Medical device Class I.
- Manufacturer: Helmut Zepf Medizintechnik GmbH.
- Reference: 46.057.11.
- Reserved for healthcare professionals. Read instructions carefully before use.
| Manufacturer: Helmut Zepf |
Complete your order
Our customers often order these together
What are Helmut Zepf La Grange scissors?
La Grange scissors, referenced under code 46.057.11 by the manufacturer Helmut Zepf, are 11.5cm surgical instruments intended for the manipulation of soft tissues. Manufactured from high-quality medical stainless steel, these instruments belong to the Class I device category. Their structure is specifically adapted to the requirements of oral surgery to ensure a clean and precise cut. This device is delivered non-sterile and must undergo a complete cleaning, disinfection, and sterilization cycle before its first use and after each surgical act.
What are the clinical indications for these gum scissors?
Ces ciseaux sont conçus pour la séparation et la coupe de tissus. En pratique clinique, ils sont principalement utilisés pour des interventions sur les tissus gingivaux, permettant des incisions précises lors de lambeaux ou de gingivectomies. Au-delà de la résection tissulaire, ils servent également à couper des aides chirurgicales telles que les fils de suture et les drains. Leur utilisation est strictement réservée aux praticiens qualifiés en chirurgie orale et implantologie. Dispositif médical de Classe I. Marquage CE. Lire attentivement la notice d'utilisation et l'étiquetage.
What are the technical characteristics of instrument 46.057.11?
Les ciseaux La Grange Helmut Zepf (référence 46.057.11) mesurent 11,5 cm de longueur totale, offrant un compromis optimal entre maniabilité et accès aux zones postérieures de la cavité orale. Ils sont entièrement conçus en acier inoxydable de qualité médicale, garantissant une résistance aux cycles de retraitement répétés. De par leur conception et les matériaux utilisés, il n'y a pas de limite maximale définie pour le nombre de cycles de traitement, à condition que l'intégrité de l'instrument soit vérifiée avant chaque utilisation. Le praticien doit s'assurer de l'absence de dommages visibles, tels que des fissures ou des défauts sur les bords tranchants.
What are the contraindications for using this instrument?
The main contraindication mentioned by Helmut Zepf concerns metal intolerance. Contact with this medical stainless steel instrument can trigger a hypersensitivity reaction in certain sensitive patients. If such a reaction occurs during the intervention, the procedure must be stopped immediately and the necessary clinical measures must be taken. It is also contraindicated to use the instrument if it shows visible signs of wear, cracks, breaks, or defects on the cutting edges, as this could compromise patient safety and the effectiveness of the surgical gesture.
What are the maintenance and reprocessing precautions?
All Helmut Zepf instruments must be cleaned, disinfected, and sterilized before the first use, and then after each subsequent use. It is crucial to perform a complete cleaning to remove all residue before the sterilization cycle. Before each use, the practitioner must carefully inspect the instrument to detect any visible damage or wear. Damaged or worn products must never be used. Although the number of achievable treatment cycles is not limited by a fixed value, the longevity of the instrument depends directly on compliance with cleaning protocols and systematic verification of compatibility with other products used.
Who is the manufacturer and what standards are met?
Ce dispositif est fabriqué par Helmut Zepf Medizintechnik GmbH, situé à Seitingen-Oberflacht, Allemagne. Il s'agit d'un dispositif médical de Classe I, conforme aux réglementations en vigueur pour les instruments chirurgicaux réutilisables. Ces instruments sont destinés exclusivement aux professionnels de santé. La traçabilité et la qualité de fabrication répondent aux normes rigoureuses de l'acier inoxydable médical. Chaque instrument est livré non stérile, la responsabilité de la stérilisation finale incombant au praticien, conformément aux instructions de sécurité fournies par Helmut Zepf.
State of the art