Skip to Content

2 x eMax Dental Flame Medium Polishing Instruments DPO02 (Handpiece) - Meisinger - (64DPO02104040) - Delynov

https://www.delynov.fr/web/image/product.template/11236/image_1920?unique=4b1e64f

The x2 polissoirs dentaires eMax flamme moyen DPO02 (pièce à main) - Meisinger - is a medical device manufactured by Hager & Meisinger GmbHClass IIa, CE marking CE0044.

  • Compliance: Medical device Class IIa, CE marking CE0044.
  • Manufacturer: Hager & Meisinger GmbH.
  • Reference: 64DPO02104040.
  • Reserved for healthcare professionals. Read instructions carefully before use.

16.79 € 16.79 EUR 16.79 € Tax Included 23.00 €

16.79 € Tax Included 23.00 €

(0.00 € / Units)
  • Manufacturer

This combination does not exist.

GBR

What is the Meisinger flame emax polisher?

The flame emax polisher from the Meisinger brand is a high-precision rotary instrument designed for working with modern ceramics, particularly lithium disilicate. This model, referenced under code 64DPO02104040, features a medium grit identified by its color and specific structure. It is mounted for use on a handpiece, providing the stability necessary during prosthetic finishing phases. This Class IIa medical device meets the quality requirements of the manufacturer Hager & Meisinger GmbH, guaranteeing grain consistency essential to avoid creating micro-cracks on the ceramic structure during rotation.

What are the clinical indications for this handpiece polisher?

This flame dental polisher is indicated for polishing eMax ceramic restorations. Its use primarily occurs during the finishing phase after occlusal or proximal adjustments made with more abrasive diamond instruments. In prosthetic surgery and restorative dentistry, it allows for restoring the initial surface state of the ceramic, thus preventing bacterial plaque accumulation and premature wear of antagonist teeth. The manufacturer Hager & Meisinger GmbH specifies that the use of these devices is reserved for practitioners (dentists, doctors, specialists) with the required training and experience in dental diagnosis and treatment techniques.

What are the technical characteristics of the DPO02 model?

The Meisinger DPO02 polisher is distinguished by its flame shape optimized for polishing crevices and convex surfaces. Its technical reference 64DPO02104040 indicates mounting on a mandrel for handpiece (HP). The medium grit of this instrument allows for a smooth transition between roughing and the final high-gloss polishing. This product belongs to the consumables category (CONSO) and benefits from a rigorous design under CE0044 marking. The geometry of the instrument is specifically studied to dissipate heat efficiently during application on glass-ceramic materials, provided that the rotation speeds recommended by the manufacturer are respected.

What are the contraindications for the use of this device?

According to information from the manufacturer Hager & Meisinger GmbH, non-compliant use of these devices can lead to premature wear and involve risks for patients and users. Although specific contraindications are not exhaustively listed in the provided documentation, it is imperative that the physician decides, under their sole responsibility, on the use on a case-by-case basis. Use is prohibited for any practitioner who does not have the necessary knowledge in dental implantology or maxillary surgery. Any serious incident related to the use of this dental flame polisher must be immediately notified to the manufacturer and the competent authority of the Member State.

What are the precautions for use and maintenance?

To ensure the safety and effectiveness of the handpiece polisher, the practitioner must refer to the specifications in the Meisinger catalog. Non-compliant use can alter the physical properties of the instrument and compromise the clinical result. It is essential to check the integrity of the instrument before each use. Like any Class IIa rotary device, inappropriate rotation speed or excessive pressure could damage the eMax ceramic or cause pulpal overheating if the work is performed intra-orally. Compliance with standard cleaning and sterilization protocols for dental rotary instruments is required to maintain the cutting and polishing performance of the medium grit.

Who is the manufacturer and what standards are respected?

This device is manufactured by Hager & Meisinger GmbH, a company located in Neuss, Germany. This recognized manufacturer complies with strict European standards relating to medical devices, as evidenced by the CE0044 marking. The product is classified as Class IIa according to current regulations. Meisinger regularly offers continuing education sessions to support practitioners in the optimal use of their surgical and prosthetic devices. Detailed information on applications and product compliance is accessible via the manufacturer's technical specifications and on their official online platform.


State of the art

Surgical medical consumables play a decisive role in operative safety.

Specifications

Manufacturer Meisinger
Tags
Tags
GBR