Perry #1 tweezers - Hu-Friedy - Delynov
The Précelle Perry #1- Hu-Friedy is a medical device manufactured by Hu-Friedy Mfg. Co., LLC.
- Compliance: Medical device Class I.
- Manufacturer: Hu-Friedy Mfg. Co., LLC.
- Reserved for healthcare professionals. Read instructions carefully before use.
What is the Perry #1 (DP1) - Hu-Friedy - Delynov dressing pliers?
The Perry #1 (DP1) dressing pliers are a manual gripping instrument developed by the manufacturer Hu-Friedy Mfg. Co., LLC. Classified as a technical consumable in the surgical inventory, these perry forceps are specifically designed to meet the requirements for fine manipulation in a clinical setting. Its structure allows for a stable grip on lightweight accessories, such as dressing materials or small prosthetic components. As a Hu-Friedy brand device, this instrument benefits from the expertise of a recognized manufacturer in the dental sector, guaranteeing a design adapted to sterilization protocols and intensive use in oral surgery or implantology practices.
What are the clinical indications for these dental perry forceps?
The use of dental perry forceps is indicated in a multitude of daily clinical procedures. It is primarily used for handling sterile materials, placing cotton rolls for surgical field isolation, or removing loose debris. In implant and periodontal surgery, the perry dressing pliers facilitate the transfer of small items without direct manual contact, thus preserving the sterility chain. It is also used to grasp membranes or filling materials before their placement. Its versatility makes it a basic tool for the practitioner during clinical examination or surgical treatment phases.
What are the technical characteristics of this instrument?
The Hu-Friedy perry dressing pliers feature technical characteristics optimized for maneuverability in the intraoral zone. Although specific dimensions are not detailed, its DP1 design corresponds to a recognized standard shape for the balance between jaw length and central spring tension. These dental gripping forceps are manufactured to withstand thermal cleaning and disinfection cycles. Its geometry allows for precise transmission of the force exerted by the practitioner's fingers, ensuring a firm hold on the grasped objects without risk of accidental slippage during surgical or prosthetic maneuvers.
What are the contraindications for the use of the perry dressing pliers?
According to data from the manufacturer Hu-Friedy Mfg. Co., LLC, specific contraindications are not exhaustively listed beyond unintended uses for Class I manual instrumentation. However, it is contraindicated to use this instrument for prying or twisting rigid structures that could deform the perry forceps jaws. Use must be strictly limited to qualified healthcare professionals who have read the instructions for use. Any use on a patient with a known sensitivity to the constituent materials of the instrument (although not specified here) must be subject to a prior clinical evaluation by the surgeon.
What are the maintenance precautions for this non-resorbable instrument?
As a non-resorbable metallic instrument, the perry dressing pliers require a rigorous maintenance protocol to guarantee longevity and patient safety. After each procedure, the instrument must be cleaned, decontaminated, and sterilized in accordance with the Hu-Friedy manufacturer's instructions. It is imperative to check for the absence of corrosion or tip deformation before each use. Storage must be carried out in a dry and clean environment. Particular attention must be paid to cleaning the joints or gripping areas to eliminate any biological residue, thus ensuring constant performance during dental surgery phases.
Who is the manufacturer and what standards are met?
The perry #1 (DP1) dressing pliers are manufactured by Hu-Friedy Mfg. Co., LLC, located at 3232 N. Rockwell St. Chicago, Il 60618 USA. This medical device is classified as Class I according to current regulations. Compliance with manufacturing standards by Hu-Friedy ensures that the instrument meets the safety and performance requirements for professional use in a dental practice. It is reminded that this product is exclusively reserved for healthcare professionals. Before any use, the practitioner must imperatively read the instructions provided by the manufacturer carefully to ensure compliance with intended use protocols and safety warnings.
State of the art
Surgical medical consumables play a decisive role in operative safety.
Specifications
| Manufacturer | Hu-Friedy |