The Sonde micro-chirurgie #1 manche #31 - Hu-Friedy is a medical device manufactured by Hu-Friedy Mfg. Co., LLC.
- Compliance: Medical device Class I.
- Manufacturer: Hu-Friedy Mfg. Co., LLC.
- Reserved for healthcare professionals. Read instructions carefully before use.
| Manufacturer: Hu-Friedy |
Complete your order
Our customers often order these together
What is the Hu-Friedy #1 micro-surgery probe with #31 handle?
The #1 micro-surgery probe mounted on a #31 handle is a diagnostic and exploration instrument manufactured by Hu-Friedy Mfg. Co., LLC. This device is distinguished by its extreme thinness, an essential characteristic for micro-surgery interventions where visibility and access are restricted. As a high-quality micro-surgery instrument, it is specifically developed to meet the requirements of practitioners performing precision acts. Its monobloc or assembled structure according to Hu-Friedy standards ensures optimal tactile transmission during the examination of soft or hard tissues. This device belongs to the category of non-invasive manual instruments used in daily practice to secure complex surgical procedures.
What are the clinical indications for this instrument?
Cette fine sonde chirurgicale est principalement indiquée dans les protocoles de micro-chirurgie. Elle est utilisée pour l'exploration des sulcus, la détection de micro-fractures, ou l'évaluation des défauts osseux lors des chirurgies parodontales ou pré-implantaires. En micro-chirurgie orale, elle permet un sondage très délicat des zones difficiles d'accès sans traumatiser les tissus adjacents. Son utilisation est également pertinente pour vérifier l'adaptation des membranes ou le positionnement des greffes de tissu conjonctif. Hu-Friedy a conçu cet instrument pour offrir une réponse adaptée aux besoins de la chirurgie orale moderne, où la préservation tissulaire est une priorité absolue pour le succès clinique à long terme.
What are the technical characteristics of the micro-surgery probe?
La sonde de micro-chirurgie #1 se caractérise par une extrémité de travail d'une finesse remarquable, optimisée pour la micro-chirurgie orale. Le manche #31 offre une prise spécifique, permettant un contrôle précis de la pression exercée lors du sondage. Cette sonde bénéficie d'une expertise métallurgique, garantissant une résistance adéquate malgré sa finesse. Contrairement aux sondes standard, ce modèle est dédié aux environnements chirurgicaux sous grossissement (loupes ou microscope), où chaque détail compte. Sa conception permet une stérilisation répétée selon les protocoles standard en vigueur dans les cabinets de chirurgie orale, assurant ainsi une longévité conforme aux attentes des praticiens les plus exigeants.
What are the contraindications for the use of this Hu-Friedy probe?
According to the information provided by Hu-Friedy Mfg. Co., LLC, the use of this instrument is strictly reserved for qualified healthcare professionals. Although no specific medical contraindication related to a material has been listed in the raw data, general principles of asepsis and safety must be respected. The instrument must not be used for leverage tasks or the application of excessive force that could lead to its breakage, given its structural thinness. It is imperative to read the instructions carefully before use to identify any patient-specific usage restrictions, particularly in case of known allergies to the standard metallic components of Class I surgical instruments.
What are the maintenance precautions for this non-resorbable instrument?
As it is a manual instrument made of surgical steel and not a resorbable device, maintenance relies on rigorous cleaning, disinfection, and sterilization cycles. After each micro-surgery intervention, the probe must be cleaned to remove all organic debris. It is recommended to use neutral pH cleaning solutions to preserve the surface condition of the Hu-Friedy instrument. Particular attention must be paid to the fine tip of the micro-surgery probe to avoid any mechanical shock that could bend or dull it. Compliance with steam sterilization parameters, as recommended by the manufacturer, guarantees the maintenance of mechanical properties and microbiological safety for subsequent patients.
Who is the manufacturer and what standards are respected?
Ce dispositif est fabriqué par Hu-Friedy Mfg. Co., LLC, dont le siège est situé au 3232 N. Rockwell St. Chicago, Il 60618 USA. Ce produit est classé comme un dispositif médical de Classe I, ce qui implique la conformité aux exigences réglementaires fondamentales pour les instruments chirurgicaux réutilisables. La réputation de Hu-Friedy en tant que fabricant reconnu dans le secteur de la chirurgie orale garantit une fabrication selon des standards de qualité élevés. Les praticiens doivent systématiquement se référer aux instructions d'utilisation fournies pour assurer la conformité aux protocoles de sécurité et de maintenance en vigueur, conformément à la réglementation relative aux dispositifs médicaux.
State of the art
Specialized surgical instrumentation is evolving towards ergonomic designs.