The Sonde parodontale UNC #UNC12 manche #6 Qulix 1-2-3....11-12 - Hu-Friedy is a medical device manufactured by Hu-Friedy Mfg. Co., LLC.

  • Compliance: Medical device Class I.
  • Manufacturer: Hu-Friedy Mfg. Co., LLC.
  • Reserved for healthcare professionals. Read instructions carefully before use.

46.20 € 46.2 EUR 46.20 € Tax Included

46.20 € Tax Included

(0.00 € / Units)
  • Manufacturer

This combination does not exist.

Instrument

What is the Hu-Friedy UNC12 periodontal probe?

The UNC12 periodontal probe is a manual examination instrument designed by the manufacturer Hu-Friedy Mfg. Co., LLC. This device consists of a fine, graduated working part mounted on a number 6 handle. It is specifically developed for the exploration of the sulcus and periodontal pockets. Unlike standard probes, this UNC (University of North Carolina) model features continuous marking allowing for millimeter evaluation. Hu-Friedy manufacturing quality guarantees a calibrated tip for precise insertion without unnecessary trauma to soft tissues. This instrument belongs to the Class I device category, meeting safety requirements for non-invasive examinations in dental surgery.

What are the clinical indications for this instrument?

The use of this unc12 periodontal probe is indicated for the diagnosis and monitoring of periodontal and peri-implant pathologies. In clinical practice, it allows for measuring probing depth, determining the clinical attachment level, and evaluating gingival recession. It is also used to check for bleeding on probing, a key indicator of tissue inflammation. During implant surgeries, it aids in planning by measuring soft tissue thickness or verifying dimensions during site preparation. Its versatility makes it a standard tool for comprehensive periodontal assessments and regular patient maintenance.

What are the technical characteristics of the UNC #UNC12 probe?

The UNC12 periodontal probe is distinguished by its Qulix marking, which features precise black graduations ranging from 1 to 12 millimeters (1-2-3-4-5-6-7-8-9-10-11-12). These visual cues facilitate rapid and exact reading of clinical measurements. The instrument is equipped with the Hu-Friedy #6 handle, offering a grip adapted to the requirements of fine periodontology. The thinness of the shank allows access to narrow areas, particularly at furcations or tight interproximal spaces. As a Class I device, its design respects the rigorous manufacturing standards of Hu-Friedy Mfg. Co., LLC, ensuring adequate resistance to standard sterilization cycles in the dental office.

What are the contraindications for using this probe?

There are no listed absolute medical contraindications for the use of a steel periodontal probe, outside of clinical situations where tissue integrity does not allow for a manual examination. However, the manufacturer specifies that the use of this instrument is strictly reserved for qualified healthcare professionals. Inappropriate use, such as excessive pressure during probing, can lead to erroneous measurements or damage the epithelial attachment. The instructions for use should always be consulted and aseptic protocols respected to avoid any cross-contamination, in accordance with Hu-Friedy recommendations for Class I devices.

What are the maintenance and storage precautions?

Although this instrument is non-absorbable and intended for repeated use, its longevity depends on compliance with cleaning and sterilization protocols. The probe must be carefully cleaned after each intervention to remove organic debris before autoclaving. It is recommended to follow the specific instructions from Hu-Friedy Mfg. Co., LLC regarding compatible cleaning agents to preserve the readability of the Qulix graduations. Regular inspection of the tip is necessary to ensure it is neither bent nor dull, which could compromise the accuracy of the periodontal diagnosis. Storage in a dry and clean environment is imperative.

Who is the manufacturer and what standards are met?

The UNC12 periodontal probe is manufactured by Hu-Friedy Mfg. Co., LLC, located at 3232 N. Rockwell St. Chicago, USA. This manufacturer is globally recognized for the high quality of its manual instrumentation. The product is classified as a Class I medical device according to current regulations. Although specific CE marking is not detailed in the provided sources, the instrument meets the manufacturing standards required for professional use in dental and periodontal surgery. Practitioners must read the instructions carefully before use to ensure application in accordance with the safety and efficacy guidelines defined by Hu-Friedy.


State of the art

Specialized surgical instrumentation is evolving towards ergonomic designs.

Specifications

Manufacturer Hu-Friedy
Tags
Tags
Instrument