Modified McCall Turgeon curette #17/18S handle #6
The Curette McCall Turgeon modifiée #17/18S manche #6 is a medical device manufactured by le fabricant.
- Compliance: Medical device Class I.
- Manufacturer: le fabricant.
- Reserved for healthcare professionals. Read instructions carefully before use.
| Manufacturer: Hu-Friedy |
Complete your order
Our customers often order these together
What is the modified McCall Turgeon curette #17/18S handle #6?
The modified McCall Turgeon curette #17/18S is a precision manual instrument developed by the manufacturer Hu-friedy for the brand Hu-Friedy. This device, belonging to the INSTRU category, is specifically configured with a #6 handle to offer a grip adapted to the requirements of periodontology. As a periodontics curette, its structure is optimized to access complex clinical zones. This medical device is classified as a Class I instrument, meeting rigorous manufacturing standards for repeated use after sterilization in a clinical setting. Its modified design allows it to meet specific needs for curettage and cleaning of root surfaces during periodontal care.
What are the clinical indications for this instrument?
Cette curette parodontale de la marque Hu-Friedy est destinée au traitement des maladies parodontales. Elle est indiquée pour le détartrage sous-gingival profond et le surfaçage radiculaire. Les praticiens utilisent la McCall Turgeon modifiée #17/18S pour l'élimination mécanique du tartre sous-gingival et du biofilm bactérien accumulé dans les poches parodontales. Elle est également employée pour l'élimination du tissu de granulation lors de la chirurgie à lambeau ou du curetage gingival. Son utilisation est strictement réservée aux professionnels de santé qualifiés, tels que les chirurgiens oraux et les parodontologues, dans le cadre de protocoles thérapeutiques visant à restaurer la santé des tissus de soutien.
What are the technical characteristics of this instrument?
La curette McCall Turgeon modifiée #17/18S se distingue par sa configuration technique spécifique sous la référence de manche #6. Fabriquée par Hu-Friedy, elle présente des extrémités actives conçues pour une efficacité de coupe optimale lors du débridement parodontal. En tant que dispositif de Classe I, elle est conçue pour résister aux cycles de décontamination et de stérilisation requis dans un cabinet de chirurgie orale. La géométrie de la partie travaillante #17/18S est adaptée pour atteindre des zones anatomiques précises, facilitant le passage dans les espaces interproximaux et le long des racines. Le manche #6 est sélectionné pour son diamètre et sa texture, permettant le contrôle tactile nécessaire lors des manœuvres de curetage exigeant une force contrôlée.
What are the contraindications for the use of this curette?
According to the information provided by the manufacturer Hu-friedy, specific contraindications are not listed exhaustively beyond general warnings. However, the use of this instrument from the brand Hu-Friedy is strictly reserved for trained healthcare professionals. Inappropriate use by unqualified personnel constitutes a major contraindication. Furthermore, as with any periodontics curette, its use may be contraindicated on dental surfaces presenting unmanaged extreme hypersensitivity or on fragile prosthetic restorations that could be damaged by the mechanical action of the steel. The instructions for use should be systematically referred to before any intervention to ensure patient safety.
What are the maintenance precautions for this non-absorbable instrument?
As a reusable Class I surgical instrument and not an absorbable device, the modified McCall Turgeon curette #17/18S requires a rigorous maintenance protocol. After each use in surgery or periodontics care, the instrument must be cleaned, disinfected, and sterilized in accordance with the instructions from the manufacturer Hu-friedy located in Chicago, USA. Professionals must regularly inspect the condition of the cutting edges of the periodontics curette to maintain its clinical effectiveness. Periodic sharpening may be necessary, while respecting the original morphology of the #17/18S tip. Compliance with these precautions ensures the longevity of the Hu-Friedy instrument and prevents the risks of cross-contamination between patients.
Who is the manufacturer and what standards are respected?
Ce dispositif est fabriqué par Hu-Friedy, dont le siège est situé au 3232 N. Rockwell St. Chicago, Il 60618 USA. Commercialisé sous la marque Hu-Friedy, il bénéficie d'une classification réglementaire de Classe I. Cette classification atteste que l'instrument répond aux exigences de sécurité et de performance définies pour les dispositifs médicaux manuels non invasifs ou invasifs à usage temporaire. Conformément au Règlement sur les Dispositifs Médicaux (MDR), cet instrument est réservé exclusivement à un usage professionnel. Il est impératif de lire attentivement la notice d'utilisation avant usage pour garantir la conformité aux protocoles de sécurité et d'hygiène en vigueur dans l'Union Européenne et à l'international.
State of the art
Specialized surgical instrumentation is evolving towards ergonomic designs.