Skip to Content

Spreaders Austin number 2 - Hu-Friedy - Delynov

https://www.delynov.fr/web/image/product.template/25568/image_1920?unique=53e897d

The Ecarteur Austin #2 - Hu-Friedy is a medical device manufactured by Hu-Friedy Mfg. Co., LLC.

  • Compliance: Medical device Class I.
  • Manufacturer: Hu-Friedy Mfg. Co., LLC.
  • Reserved for healthcare professionals. Read instructions carefully before use.

160.20 € 160.2 EUR 160.20 € Tax Included

160.20 € Tax Included

(0.00 € / Units)
  • Manufacturer

This combination does not exist.

Instrument

What is the Austin #2 - Hu-Friedy - Delynov retractor?

The Austin #2 retractor is a manual surgical instrument manufactured by Hu-Friedy Mfg. Co., LLC. This device, categorized as a consumable (CONSO), is specifically designed for tissue retraction during oral procedures. Its structure is engineered to provide stable support and precise handling by the surgeon or their assistant. As an austin dental retractor, it allows soft tissues to be held away from the working area, thus ensuring secure access to target anatomical structures. This model benefits from the expertise of Hu-Friedy, a manufacturer recognized for the quality of its surgical instrumentation intended for dental practices and hospitals.

What are the clinical indications for this retractor?

The austin surgery retractor is indicated for the retraction of flaps, cheeks, and lips during various clinical procedures. In oral surgery, it is used to clear the field during the extraction of impacted teeth or apical resection. In implantology, this austin dental retractor allows for maintaining clear visibility of the alveolar ridge during drilling or implant placement. Its use is also relevant in periodontology for the exposure of bone defects. According to Hu-Friedy manufacturer guidelines, the use of this instrument is strictly reserved for qualified healthcare professionals, ensuring handling in compliance with current surgical protocols.

What are the technical characteristics of the instrument?

The Hu-Friedy Austin #2 retractor features technical characteristics adapted to the constraints of the oral cavity. Although the exact composition is not specified, this instrument belongs to Class I of medical devices, meeting regulatory requirements for non-invasive surgical tools or those reusable after sterilization. Its ergonomic design allows for a firm grip, reducing fatigue during prolonged interventions. The shape of the working part is optimized to adapt to the vestibular anatomy, allowing effective retraction without cluttering the surgeon's workspace. The technical reference Austin #2 corresponds to a specific configuration within the Hu-Friedy instrumentation range.

What are the contraindications for the use of this retractor?

In accordance with the information provided by Hu-Friedy Mfg. Co., LLC, specific contraindications are not detailed beyond the intended use. However, the use of this austin retractor is contraindicated for any person not having the qualification of a healthcare professional. It is imperative not to use the instrument in case of visible damage to the surface, which could compromise asepsis or injure the patient's soft tissues. As with any Class I surgical instrument, a prior clinical evaluation of the patient's tissue condition is necessary to avoid any excessive application of force that could lead to tissue trauma or unintended mucosal lacerations.

What are the precautions for use and maintenance?

As a non-resorbable and reusable device, this austin retractor requires a rigorous decontamination and sterilization protocol between each patient. The manufacturer Hu-Friedy emphasizes the importance of reading the instructions carefully before use. Professionals must inspect the instrument before each intervention to ensure the absence of corrosion or deformation. During retraction, controlled pressure should be applied to avoid damaging the mucoperiosteal flaps. Compliance with the cleaning cycles recommended by the manufacturer is essential to maintain the integrity of the instrument and ensure microbiological safety within the operating block or dental practice.

Who is the manufacturer and what standards are respected?

The Austin #2 retractor is manufactured by Hu-Friedy Mfg. Co., LLC, headquartered at 3232 N. Rockwell St. Chicago, Il 60618 USA. This medical device is classified as Class I according to current regulations. Hu-Friedy is a manufacturer recognized for its compliance with strict manufacturing standards, ensuring the traceability and conformity of its surgical instruments. Although CE marking is not explicitly specified in the source data, the product meets the safety and performance requirements for its intended use as an instrument reserved for healthcare professionals. Each user must refer to the raw MDR text for legal warnings and specific instructions for use.


State of the art

Surgical medical consumables play a decisive role in operative safety.

Specifications

Manufacturer Hu-Friedy
Tags
Tags
Instrument