Internal Diameter 6.0 MM Trepan. - Helmut Zepf (08.910.08F)

https://www.delynov.fr/web/image/product.template/21901/image_1920?unique=0cc8cca

The TREPAN. DIAMETRE INTERNE 6.0 MM - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.

  • Compliance: Medical device Class IIa.
  • Manufacturer: Helmut Zepf Medizintechnik GmbH.
  • Reference: 08.910.08F.
  • Reserved for healthcare professionals. Read instructions carefully before use.

89.53 € 89.53 EUR 89.53 €excl. VAT

89.53 €excl. VAT

(0.00 € / Units)
  • Manufacturer

This combination does not exist.

Instrument
Manufacturer: Helmut Zepf

What is the Helmut Zepf 08.910.08F trephine?

The Helmut Zepf trephine (reference 08.910.08F) is a precision surgical rotary instrument designed for the circular cutting of bone tissue. This bone harvesting trephine features an internal diameter of 6.0 mm, allowing for the creation of perfectly calibrated cylindrical bone blocks. Manufactured by Helmut Zepf Medizintechnik GmbH, this Class IIa medical device is intended to be mounted on a surgical contra-angle. Its structure is optimized to guarantee a clean cut while allowing the recovery of a high-quality autologous bone graft, ready to be used for volume augmentations or further processed in a bone mill according to the clinical needs of the reconstruction.

What are the clinical indications for this 6mm trephine drill?

Ce trépan de prélèvement osseux est principalement indiqué en chirurgie orale et en implantologie pour deux applications majeures. Il est utilisé pour obtenir des blocs osseux cylindriques à partir de la mâchoire du patient, fournissant un matériau de greffe autologue pour combler les défauts osseux ou renforcer les sites implantaires. Cet instrument est également indiqué pour l'explantation d'implants déjà intégrés. Dans ce contexte, le praticien choisit le diamètre du trépan en fonction des dimensions de l'implant à retirer afin de réaliser une ostéotomie périphérique minimale facilitant le retrait du dispositif sans endommager excessivement les structures environnantes.

What are the technical and handling characteristics?

The Helmut Zepf 6.0 mm trephine must be attached to a contra-angle. For obtaining bone blocks, the motor must be set to a speed between 800 rpm and its maximum authorized speed. For explantation procedures, the recommended speed is between 800 rpm and 1000 rpm maximum. The drilling or milling process must be carried out using continuous in-and-out movements (pumping movement) to avoid thermal overheating. Abundant irrigation with sterile physiological saline solution is imperative, whether manually or via the internal irrigation system of the contra-angle. It is crucial not to stop the motor while the trephine is inserted in the surgical cavity to avoid any blockage or breakage of the instrument.

What are the contraindications for the use of this instrument?

The use of this trephine is strictly reserved for healthcare professionals qualified in oral surgery and implantology. Although the manufacturer does not list specific systemic contraindications in the provided technical documentation, general contraindications to bone surgery and implantology apply. The practitioner must evaluate bone density and the proximity of critical anatomical structures (inferior alveolar nerve, maxillary sinus) before any intervention. Excessive pressure during drilling must be avoided to prevent the risk of thermal necrosis or instrument fracture. Use is prohibited if the conditions of sterility or maintenance of the instrument are not guaranteed.

What are the precautions for use and removal?

When using the Helmut Zepf trephine, particular attention must be paid to the management of the pressure exerted. Excessive pressure can compromise the precision of the cut or damage the bone tissue. During drilling, it is essential to keep the motor rotating during insertion and especially during removal from the surgical cavity; stopping the rotation prematurely can lead to the trephine jamming or breaking. Physiological rinsing must be constant to evacuate bone debris and cool the cutting surfaces. After the procedure, the number of achievable processing cycles depends on the observed wear, as there is no maximum limit defined by the manufacturer, requiring a rigorous visual inspection by the professional.

Who is the manufacturer and what standards are respected?

Ce dispositif médical est fabriqué par Helmut Zepf Medizintechnik GmbH, à Seitingen-Oberflacht, Allemagne. C'est un instrument de Classe IIa, conforme aux exigences réglementaires européennes pour les dispositifs médicaux invasifs de type chirurgical. En tant que fabricant reconnu en instrumentation de haute précision pour la chirurgie orale, Helmut Zepf garantit un processus de fabrication rigoureux. Le produit est identifié par la référence technique 08.910.08F. Les praticiens doivent se référer à la notice d'utilisation pour les protocoles de nettoyage, désinfection et stérilisation afin de maintenir la performance de coupe et la sécurité biologique de l'instrument lors de ses utilisations successives en cabinet ou en milieu hospitalier.


State of the art

Surgical medical consumables play a decisive role in operative safety.

Delivery

From France to the whole world.

Europe, overseas territories, worldwide. Everything ships through our own logistics.

With you tomorrow

Ordered before 2 pm, delivered within 24 h. Otherwise, within 72 h.

Delivery included from €500 incl. VAT

Offer limited to mainland France.

A team that answers

Orders, traceability, materiovigilance, your dedicated contact in Épinal. Parcels prepared by the ESAT of Dinozé.

We’ll call you back

References

They trust us.

Public and private healthcare institutions order from Delynov.