Trephine. Internal diameter 7.0 MM - Helmut Zepf (08.910.09F) - Delynov
The TREPAN. DIAMETRE INTERNE 7.0 MM - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.
- Compliance: Medical device Class IIa.
- Manufacturer: Helmut Zepf Medizintechnik GmbH.
- Reference: 08.910.09F.
- Reserved for healthcare professionals. Read instructions carefully before use.
| Manufacturer: Helmut Zepf |
Complete your order
Our customers often order these together
What is the Helmut Zepf 08.910.09F trephine?
The Helmut Zepf trephine, bearing reference 08.910.09F, is a specialized rotary instrument designed for bone surgery. This surgical trephine has an internal diameter of 7.0 mm, making it suitable for harvesting bone cores of specific dimensions. Manufactured by Helmut Zepf Medizintechnik GmbH, this medical device belongs to the category of surgical consumables. Its structure is optimized for the circular cutting of hard tissues, allowing for the extraction of clean bone cylinders. It is primarily used in bone reconstruction protocols or during the removal of implantable devices. As a bone trephine drill, it is part of the arsenal for practitioners performing autogenous harvesting or complex corrective interventions in the maxillary or mandibular areas.
What are the clinical indications for this 7mm trephine drill?
Cette tréphine est indiquée pour deux applications cliniques principales en chirurgie orale. Premièrement, elle est utilisée pour créer des blocs osseux cylindriques prélevés directement de la mâchoire du patient. Ces blocs peuvent ensuite être utilisés tels quels pour des greffes en onlay ou insérés dans un broyeur osseux pour obtenir un matériau de comblement particulaire pour des traitements ultérieurs. Deuxièmement, cet instrument est spécifiquement indiqué pour l'explantation d'implants déjà intégrés. Sa conception lui permet de contourner l'implant pour libérer les tissus environnants et faciliter son retrait. Le choix de ce diamètre interne de 7,0 mm doit être rigoureusement adapté au diamètre du bloc de tissu osseux désiré ou à la taille de l'implant à retirer selon les besoins de la procédure. Marquage CE. Dispositif médical de Classe IIa. Lire attentivement la notice d'utilisation et l'étiquetage.
What are the technical characteristics and operating parameters?
The Helmut Zepf bone trephine drill has strict technical specifications to guarantee its effectiveness. For obtaining bone blocks, the motor must be set to a speed between 800 rpm and a maximum defined by the device. During explantation, the recommended speed is between 800 rpm and 1000 rpm maximum. The drilling or milling process must be performed with continuous in-and-out movements. Abundant irrigation with sterile physiological saline solution is imperative to avoid tissue overheating. This rinsing can be manual or coupled with the contra-angle irrigation system. It is crucial not to apply excessive pressure during treatment and to keep the motor rotating as long as the trephine is inside the surgical cavity to avoid any blockage or breakage.
What are the contraindications for the use of this bone surgery trephine?
L'utilisation de cet instrument est strictement réservée aux professionnels de santé qualifiés. Bien que le document source ne liste pas de contre-indications médicales spécifiques liées aux pathologies systémiques, l'utilisation du trépan est conditionnée par sa manipulation technique. Une contre-indication majeure réside dans l'arrêt du moteur tant que l'instrument est engagé dans la cavité chirurgicale, ce qui peut empêcher le retrait du trépan ou provoquer sa rupture. De plus, l'application d'une pression excessive pendant le forage est interdite afin d'éviter les complications peropératoires. Le praticien doit s'assurer que le diamètre de l'instrument est parfaitement adapté à l'implant ou au volume osseux cible avant toute intervention.
What are the precautions for use and limits of use?
L'utilisation du trépan Helmut Zepf exige le respect de protocoles rigoureux de nettoyage et de stérilisation entre chaque usage. Il n'y a pas de limite maximale définie pour l'utilisation prévue, la durée de vie dépendant des cycles de traitement réalisables qui doivent être déterminés par le praticien. Il est essentiel de vérifier l'état de l'instrument avant chaque intervention pour garantir son pouvoir de coupe. Pendant l'acte chirurgical, le maintien d'un flux constant de solution physiologique stérile est la principale précaution pour préserver la viabilité des cellules osseuses et l'intégrité de l'instrument. Le respect des plages de vitesse de rotation (800 à 1000 tr/min selon l'acte) est fondamental pour la sécurité du patient et la longévité du dispositif.
Who is the manufacturer and what standards are met?
The trephine is manufactured by Helmut Zepf Medizintechnik GmbH, headquartered in Seitingen-Oberflacht, Germany. This medical device is classified as Class IIa according to current regulations. The manufacturer ensures the compliance of its instruments with safety and performance requirements for use in a surgical environment. As a Class IIa product, it meets strict quality control and manufacturing criteria. Traceability is ensured by reference code 08.910.09F. This equipment is exclusively intended for healthcare professionals trained in oral surgery and implant techniques, thus guaranteeing an application consistent with clinical data and the instructions for use provided by Helmut Zepf.
State of the art
Surgical medical consumables play a decisive role in operative safety.



















