DRILL. INTERNAL DIAMETER 5.0 MM - Helmut Zepf (08.910.13F) - Delynov
The TREPAN. DIAMETRE INTERNE 5.0 MM - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.
- Compliance: Medical device Class IIa.
- Manufacturer: Helmut Zepf Medizintechnik GmbH.
- Reference: 08.910.13F.
- Reserved for healthcare professionals. Read instructions carefully before use.
| Manufacturer: Helmut Zepf |
Complete your order
Our customers often order these together
What is the Helmut Zepf 5.0 mm trephine?
The Helmut Zepf trephine, bearing reference 08.910.13F, is a surgical rotary instrument designed for the precise circular cutting of bone tissue. This surgical trephine features an internal diameter of 5.0 mm, allowing for standardized bone core drilling. Manufactured by Helmut Zepf Medizintechnik GmbH, this device is intended for professional use in oral and implant surgery. Its structure is optimized to fit onto a surgical contra-angle in order to perform cylindrical block harvesting or to facilitate the removal of osseointegrated implants.
What are the clinical indications for the bone trephine?
Ce trépan osseux a deux indications principales. Premièrement, il est utilisé pour le prélèvement de blocs osseux cylindriques de la mâchoire. Ces carottes osseuses peuvent ensuite être utilisées telles quelles pour des greffes en onlay ou insérées dans un broyeur osseux pour un traitement ultérieur avant comblement. Deuxièmement, l'instrument est indiqué pour l'explantation d'implants. En choisissant un diamètre adapté à l'implant à retirer, le praticien peut dégager la périphérie de la vis implantaire pour permettre son retrait lors de complications ou de défaillances implantaires.
What are the technical and handling characteristics?
This 5mm trephine drill (internal diameter) must be attached to a contra-angle. To obtain bone blocks, the manufacturer recommends setting the motor at a speed between 800 rpm and the maximum authorized by the device. For implant explantation, the recommended speed is between 800 rpm and 1000 rpm maximum. The drilling or milling process must be performed with continuous in-and-out movements. Abundant irrigation with sterile physiological saline solution is mandatory, either manually or via the contra-angle cooling system, to avoid thermal overheating of the tissues.
What are the contraindications and precautions for use?
Although the manufacturer does not list specific medical contraindications related to the material, strict handling precautions apply. Excessive pressure must not be exerted during treatment. It is crucial not to stop the motor while the trephine is inside the surgical cavity; a premature stop can prevent the removal of the instrument or cause it to break. Use is strictly reserved for qualified healthcare professionals. The practitioner must choose the trephine diameter based on the diameter of the desired tissue block or the implant to be extracted to ensure the safety of the procedure.
What are the precautions related to the product life cycle?
La tréphine Helmut Zepf est classée dans la catégorie des consommables réutilisables selon les protocoles de traitement appropriés. Il n'y a pas de limite maximale définie pour l'utilisation prévue, mais les cycles de traitement réalisables doivent être déterminés par le praticien. L'instrument doit être inspecté avant chaque utilisation pour vérifier son intégrité. Un rinçage abondant et continu pendant l'acte chirurgical est essentiel pour maintenir la performance de coupe et la viabilité des tissus environnants. Le respect des paramètres de vitesse du moteur (800 à 1000 tr/min selon l'acte) est un facteur clé pour la longévité de l'instrument.
Who is the manufacturer and what standards are met?
The device is manufactured by Helmut Zepf Medizintechnik GmbH, located in Seitingen-Oberflacht, Germany. This trephine is a Class IIa medical device according to current regulations. As a Helmut Zepf product, it benefits from the expertise of a manufacturer recognized in high-precision surgical instrumentation. Compliance with cleaning, disinfection, and sterilization protocols is necessary between each patient, in accordance with the manufacturer's instructions for devices of this regulatory class, to guarantee clinical safety and compliance with medical sector requirements.
State of the art
Surgical medical consumables play a decisive role in operative safety.