Dental surgery control flag holders - Helmut Zepf (08.917.00) - Delynov
The Porte-drapeaux de contrôle pour chirurgie orale - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.
- Compliance: Medical device Class I.
- Manufacturer: Helmut Zepf Medizintechnik GmbH.
- Reference: 08.917.00.
- Reserved for healthcare professionals. Read instructions carefully before use.
| Manufacturer: Helmut Zepf |
Complete your order
Our customers often order these together
What is the Helmut Zepf control direction indicator (08.917.00)?
L'indicateur de direction Helmut Zepf, référencé sous le code 08.917.00, est un instrument manuel conçu pour assister le praticien durant les phases critiques de la chirurgie implantaire. Fabriqué en acier inoxydable médical par Helmut Zepf Medizintechnik GmbH, cet instrument robuste est destiné à un usage répété après un protocole de stérilisation rigoureux. Sa structure permet une insertion précise dans les sites de forage pour fournir une aide visuelle au chirurgien. En tant qu'indicateur de direction chirurgicale, il s'intègre au flux de travail standard pour garantir l'alignement correct des futurs implants, évitant ainsi les erreurs de positionnement spatial au sein de l'arcade alvéolaire.
Quelles sont les indications cliniques de cet indicateur de direction pour la chirurgie orale ?
This instrument is indicated for all oral surgery procedures requiring verification of axial orientation. Primarily used as an implant surgery guide, it is used after the passage of the pointer drill or pilot drills to materialize the chosen drilling axis. It helps validate parallelism in cases of multiple placements and ensures that the implant trajectory respects prosthetic and anatomical constraints. Its role as an implant direction indicator is crucial for preventing cortical fenestrations or excessive root proximity. It is exclusively reserved for use by healthcare professionals qualified in implantology and oral surgery.
What are the technical characteristics of this instrument?
The Helmut Zepf direction indicator is manufactured from high-quality medical grade stainless steel, selected for its resistance to cleaning and sterilization cycles. This Class I device is delivered non-sterile and requires complete processing before its first use. Although the manufacturer does not define a maximum limit of processing cycles due to the durable design of the instrument, it is imperative to visually inspect the product before each use. The practitioner must look for any visible damage such as cracks, breaks, or defects on the functional surfaces. Any instrument showing signs of wear or degradation must be immediately discarded.
What are the contraindications for the use of this device?
The main medical contraindication concerns patients with a known hypersensitivity or intolerance to metals, specifically to the components of medical stainless steel. Contact of the instrument with tissue can trigger a hypersensitivity reaction in these subjects. If such a reaction occurs during the intervention, the procedure must be immediately interrupted and the necessary clinical measures must be taken accordingly. Furthermore, the use of this instrument is contraindicated if the product shows visible damage (cracks, edge defects) that could compromise patient safety or the precision of the surgical gesture.
What are the maintenance and sterilization precautions?
Conformément aux instructions de Helmut Zepf Medizintechnik GmbH, tous les instruments doivent être nettoyés, désinfectés et stérilisés avant la première utilisation, puis après chaque utilisation ultérieure. Un nettoyage complet est une étape critique qui doit précéder la stérilisation pour assurer l'élimination de tous les résidus biologiques. En raison des matériaux utilisés, il n'y a pas de limite maximale définie de cycles de retraitement, mais la longévité dépend de la rigueur de l'entretien. Il est également recommandé de vérifier la compatibilité avec d'autres produits utilisés pendant la chirurgie. L'utilisation de produits endommagés ou usés est strictement interdite pour maintenir l'asepsie et l'efficacité opérationnelle.
Who is the manufacturer and what standards are respected?
Cet instrument est fabriqué par Helmut Zepf Medizintechnik GmbH, une entreprise reconnue située à Seitingen-Oberflacht, en Allemagne. L'indicateur de direction de contrôle est classé comme un dispositif médical de Classe I selon la réglementation en vigueur. La traçabilité et la qualité de fabrication des instruments manuels destinés à la chirurgie orale, l'implantologie et la parodontologie sont assurées. Chaque produit est conçu pour répondre aux exigences des praticiens, avec une attention particulière portée à la sécurité des matériaux (acier inoxydable de qualité médicale). Les instructions de sécurité et d'utilisation fournies par Helmut Zepf doivent être scrupuleusement suivies par les praticiens pour garantir la conformité de l'instrument tout au long de sa durée de vie utile.
State of the art