Skip to Content

Surgical dental extraction forceps, English pattern, figure 29, for children, Roba design - Helmut Zepf (10.685.29ZD) - Delynov

https://www.delynov.fr/web/image/product.template/170756/image_1920?unique=7f7b7b7

The Forceps chirurgical selon modèle anglais, figure 29, pour enfants, design Roba - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.

  • Manufacturer: Helmut Zepf Medizintechnik GmbH.
  • Reference: 10.685.29ZD.
  • Reserved for healthcare professionals. Read instructions carefully before use.

196.57 € 196.57 EUR 196.57 € Tax Included

196.57 € Tax Included

(0.00 € / Units)
  • Manufacturer

This combination does not exist.

Instrument

What is the Helmut Zepf extraction forceps Roba design?

The Helmut Zepf surgical forceps, reference 10.685.29ZD, is an extraction instrument specifically developed for pediatric patients. This device follows the configuration of the English pattern, figure 29, integrating the Roba design. This particular design aims to offer a geometry adapted to the reduced dimensions of the oral cavity of children. Manufactured by Helmut Zepf Medizintechnik GmbH, this child extraction forceps is a precision tool intended for dental surgeons and stomatologists performing exodontia on temporary teeth. Its structure is designed to ensure controlled force transmission while respecting the anatomical specificities of young patients.

What are the clinical indications for this pediatric forceps?

This pediatric forceps is indicated for dental extraction procedures in children. It is mainly used during the avulsion of deciduous or temporary teeth presenting advanced carious pathologies, pulp necrosis, or as part of orthodontic treatments requiring guided extractions. Its shape corresponding to figure 29 of the English pattern allows for approaching surgical sites with appropriate visibility. The use of this Helmut Zepf forceps is part of pediatric oral surgery protocols where space management and the delicacy of surrounding tissues are paramount for patient comfort and the preservation of alveolar bone.

What are the technical characteristics of model 10.685.29ZD?

The Helmut Zepf forceps reference 10.685.29ZD is distinguished by several technical specificities. It adopts figure 29 from the English pattern repertoire, a standard recognized in surgical instrumentation for its specific functionality. The Roba design integrated into this model modifies the classic ergonomics to better correspond to the hands of practitioners during pediatric procedures, while maintaining a working part proportioned to the crowns of milk teeth. The instrument is designed to offer a stable grip, preventing slippage during the luxation and rotation movements necessary for extraction. Its manufacture by Helmut Zepf Medizintechnik GmbH guarantees precise adjustment of the hinges and a rigorous surface finish.

What are the contraindications for the use of this forceps?

The contraindications for the use of this Helmut Zepf forceps are mainly related to clinical situations where simple manual extraction is not recommended. This includes cases of teeth presenting severe ankylosis requiring an alveoloplasty approach or the use of rotary instruments. Furthermore, as this model is specifically sized for children (Roba design, figure 29), it is not suitable for the extraction of permanent teeth in adults, where the forces to be applied and the coronal dimensions exceed the structural capacities of the instrument. As with any metallic instrument, a known hypersensitivity to the alloy components must be taken into account before the intervention.

What are the maintenance precautions for this non-resorbable instrument?

As a reusable surgical instrument, this Helmut Zepf forceps must follow a strict protocol of decontamination, cleaning, and sterilization between each patient. It is imperative to refer to the instructions from the manufacturer Helmut Zepf Medizintechnik GmbH regarding autoclave cycles and compatible cleaning products. Particular attention must be paid to the hinge to avoid the accumulation of organic debris and prevent corrosion. Although the instrument is robust, it is advisable to regularly check for the absence of deformations or cracks on the beaks of figure 29 to guarantee optimal safety during pediatric extraction maneuvers.

Who is the manufacturer and what standards are respected?

The official manufacturer of this device is Helmut Zepf Medizintechnik GmbH, a recognized player in the production of high-precision surgical instrumentation. Regarding specific standards and certifications such as the regulatory class or CE marking, this information is not specified in the current technical documentation for this reference 10.685.29ZD. It is therefore recommended that healthcare professionals consult the product labeling as well as the instructions for use provided by Helmut Zepf to verify compliance with the regulatory requirements in force in their geographical area before any use in a dental practice or hospital environment.


State of the art

Surgical medical consumables play a decisive role in operative safety.

Specifications

Manufacturer Helmut Zepf
Tags
Tags
Instrument