Roots - Helmut Zepf (12.045.15Z) - Delynov
The Racines - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.
- Compliance: Medical device Class I.
- Manufacturer: Helmut Zepf Medizintechnik GmbH.
- Reference: 12.045.15Z.
- Reserved for healthcare professionals. Read instructions carefully before use.
| Manufacturer: Helmut Zepf |
Complete your order
Our customers often order these together
What is the Helmut Zepf 12.045.15Z root forceps?
The Helmut Zepf root forceps, referenced under code 12.045.15Z, is a high-precision surgical instrument manufactured from medical stainless steel. This device, belonging to the consumables category (CONSO), is specifically designed for extraction procedures in oral surgery. Its robust structure allows for reliable handling when grasping radicular fragments or implants. As a Helmut Zepf Medizintechnik GmbH product, it benefits from the expertise of a manufacturer recognized for the quality of its stainless steel instruments, guaranteeing resistance adapted to the mechanical stresses of exodontia and explantation procedures.
What are the clinical indications for this universal root forceps?
Cette pince universelle est indiquée pour deux applications cliniques majeures en chirurgie orale et en milieu hospitalier. Premièrement, elle sert de pince à racines pour l'extraction de racines naturelles ou de reliquats radiculaires persistants après une fracture coronaire. Deuxièmement, elle est utilisée comme pince d'explantation pour le retrait de racines artificielles, communément appelées implants. Son usage est strictement réservé aux professionnels de santé qualifiés impliqués dans des protocoles de chirurgie orale, d'implantologie ou de parodontologie nécessitant le retrait de structures profondément ancrées dans l'os alvéolaire.
What are the technical characteristics of the 12.045.15Z device?
The Helmut Zepf 12.045.15Z instrument is characterized by its manufacture in high-quality medical stainless steel. Classified as a Class I medical device, it meets the safety requirements for non-invasive or invasive instruments for temporary use. The product is delivered non-sterile, which necessitates a rigorous cleaning, disinfection, and sterilization protocol before the first use and between each patient. Due to its design and the materials used, the manufacturer Helmut Zepf does not define a maximum limit for processing cycles, although the user must inspect the instrument for any cracks, breaks, or defects on the edges before each procedure.
What are the contraindications for using this instrument?
The main medical contraindication related to the use of these forceps lies in the patient's known hypersensitivity to metals. Contact with medical stainless steel can trigger allergic or intolerance reactions in certain individuals. If a hypersensitivity reaction is observed during the procedure, the process must be immediately stopped and the necessary clinical measures must be taken. It is therefore imperative to check the patient's allergic history before any manipulation. Furthermore, the use of the instrument is contraindicated if it shows visible damage, such as cracks or excessive wear on the active parts.
What are the maintenance and reprocessing precautions?
Reprocessing of the Helmut Zepf forceps must follow strict steps: cleaning, disinfection, and complete sterilization. Before the first use, the instrument must mandatory be treated. The practitioner must check compatibility with other cleaning products and ensure that no visible damage impairs the safety of the device. Although the number of sterilization cycles is not limited by a fixed value, the longevity of the tool depends on compliance with maintenance protocols. The use of damaged or worn products is formally prohibited to guarantee tissue integrity during the extraction of roots or implants.
Who is the manufacturer and what standards are respected?
Le dispositif est fabriqué par Helmut Zepf Medizintechnik GmbH, dont le siège est à Seitingen-Oberflacht, Allemagne. Ce fabricant est mondialement reconnu pour ses instruments de chirurgie orale. Le produit est conforme à la réglementation des dispositifs médicaux de Classe I. Les consignes de sécurité stipulent que tous les instruments doivent être inspectés avant utilisation pour détecter toute fissure ou rupture. La traçabilité est assurée par la référence technique 12.045.15Z. Les produits sont exclusivement réservés aux professionnels de santé, garantissant une utilisation conforme aux standards cliniques actuels en exodontie et chirurgie implantaire.
State of the art
Surgical medical consumables play a decisive role in operative safety.



















