Skip to Content
The Delynov team is away and back on 24 August. Your parcels will be processed with longer lead times.

English pattern dental extraction forceps, figure 321 - Helmut Zepf (12.221.90Z) - Delynov

https://www.delynov.fr/web/image/product.template/24975/image_1920?unique=cb1ae17

The Davier à forme anglaise, figure 321 - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.

  • Compliance: Medical device Class I.
  • Manufacturer: Helmut Zepf Medizintechnik GmbH.
  • Reference: 12.221.90Z.
  • Reserved for healthcare professionals. Read instructions carefully before use.

145.13 € 145.13 EUR 145.13 € Tax Included

145.13 € Tax Included

(145.13 € / Units)
  • Manufacturer

This combination does not exist.

Instrument

What is the Helmut Zepf figure 321 forceps?

The English pattern forceps, figure 321, is a manual dental instrument developed by the manufacturer Helmut Zepf Medizintechnik GmbH. Designed in medical stainless steel, this instrument is specifically dedicated to dental extraction procedures. Its robust structure meets the requirements of oral surgery by allowing optimal force transmission during avulsion. As a Class I medical device, it is intended exclusively for professional use in dental practices or hospital environments. Its technical reference 12.221.90Z allows precise identification within the Helmut Zepf range.

What are the clinical indications for this forceps?

The main indication for this Helmut Zepf forceps is manual dental extraction. It is used by dental surgeons and stomatologists to firmly grasp the tooth, facilitate its luxation, and proceed with its final removal from the socket. This instrument is used in conventional oral surgery or pre-implant protocols when the condition of the tooth requires avulsion. Its use is reserved for qualified healthcare professionals mastering extraction techniques to minimize damage to surrounding tissues.

What are the technical characteristics of this instrument?

This forceps, bearing reference 12.221.90Z, is characterized by its manufacture in high-quality medical stainless steel, guaranteeing resistance to repeated sterilization cycles. It is an English pattern instrument, figure 321, whose geometry is designed to adapt to the specific dental anatomy targeted by this figure. The product is delivered non-sterile by Helmut Zepf Medizintechnik GmbH, which requires a strict processing protocol before the first use and between each patient.

What are the contraindications for the use of the 12.221.90Z forceps?

The main medical contraindication mentioned by the manufacturer Helmut Zepf concerns known hypersensitivity or intolerance to metals. As the instrument is composed of medical stainless steel, contact with the patient may trigger an allergic reaction. If such a hypersensitivity reaction occurs during the intervention, the procedure must be immediately stopped and necessary clinical measures must be taken. It is therefore crucial to check the patient's allergic history before any use of this manual instrument.

What are the maintenance and safety precautions?

Before each use, the instrument must undergo a thorough visual inspection to detect potential damage such as cracks, breaks, or defects on the active parts. It is imperative never to use a damaged or worn product. Regarding the reprocessing cycle, all Helmut Zepf instruments must be cleaned, disinfected, and sterilized before the first use and after each subsequent use. Due to its design and the materials used, there is no defined maximum limit of processing cycles, but visible wear must guide the replacement of the instrument.

Who is the manufacturer and what standards are respected?

The forceps is manufactured by Helmut Zepf Medizintechnik GmbH, located in Seitingen-Oberflacht, Germany. This medical device belongs to Class I according to current regulations. The manufacturer emphasizes that the instrument is reserved for healthcare professionals. Compliance with cleaning and sterilization protocols is essential to guarantee patient safety and the longevity of the stainless steel. The products are delivered non-sterile, engaging the practitioner's responsibility in implementing the decontamination cycle in accordance with hospital hygiene standards.


State of the art

Surgical medical consumables play a decisive role in operative safety.

Specifications

Manufacturer Helmut Zepf
Tags
Tags
Instrument