Skip to Content
The Delynov team is away and back on 24 August. Your parcels will be processed with longer lead times.

English pattern dental extraction forceps, Figure 34N - Helmut Zepf (12.234.07ZTI) - Delynov

https://www.delynov.fr/web/image/product.template/26803/image_1920?unique=e4402a2

The Davier à forme anglaise, Figure 34N - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.

  • Compliance: Medical device Class I.
  • Manufacturer: Helmut Zepf Medizintechnik GmbH.
  • Reference: 12.234.07ZTI.
  • Reserved for healthcare professionals. Read instructions carefully before use.

224.94 € 224.94 EUR 224.94 € Tax Included 376.31 €

224.94 € Tax Included 376.31 €

(0.00 € / Units)
  • Manufacturer

This combination does not exist.

Instrument

What is the Helmut Zepf 12.234.07ZTI English pattern extraction forceps?

The English pattern extraction forceps, Figure 34N, referenced under code 12.234.07ZTI, is a manual surgical instrument developed by Helmut Zepf Medizintechnik GmbH. Designed in medical stainless steel, this device belongs to the Class I consumables category. Its structure is specifically adapted to the requirements of exodontia, offering a dental plier-like configuration for direct handling during oral surgery interventions. This equipment is delivered non-sterile and requires a complete preparation protocol before any first use in a dental practice or operating theater.

What are the clinical indications for this Helmut Zepf extraction forceps?

The primary indication for this Helmut Zepf instrument is the extraction of teeth. In clinical practice, it is used by dental surgeons and implantologists to perform simple or complex dental avulsions. The forceps allow for the application of the luxation and traction forces necessary to release the tooth from its alveolar ligament attachment. Its use is strictly reserved for qualified healthcare professionals operating within the framework of curative dental care or pre-implant preparations requiring the removal of non-restorable dental elements.

What are the technical characteristics of this instrument?

This Figure 34N forceps is characterized by its manufacture from high-quality medical stainless steel, ensuring resistance adapted to the mechanical stresses of extraction. It is a Class I medical device complying with the requirements of Helmut Zepf Medizintechnik GmbH. The product is designed to be reusable, although the manufacturer specifies that no maximum limit for processing cycles can be defined a priori. Durability depends on the absence of visible damage such as cracks, breaks, or defects on the active parts, which must be checked before each use.

What are the contraindications for the use of this device?

The main medical contraindication documented by the manufacturer Helmut Zepf concerns hypersensitivity or intolerance to metals. Contact of the medical stainless steel with an allergic patient can trigger a hypersensitivity reaction. If such a reaction occurs during the intervention, the procedure must be immediately stopped and appropriate medical measures must be taken. It is therefore crucial to assess the patient's allergic history before using this instrument in the mouth.

What are the maintenance and sterilization precautions?

Like any Helmut Zepf surgical instrument, this extraction forceps must imperatively be cleaned, disinfected, and sterilized before the first use, as well as after each subsequent use. Complete cleaning is a critical step to ensure patient safety and the longevity of the steel. The practitioner must visually inspect the instrument to detect any traces of wear, corrosion, or deformation of the jaws. The use of a damaged instrument or one presenting cracks is strictly prohibited to avoid any risk of intraoperative breakage.

Who is the manufacturer and what standards are met?

The official manufacturer of this device is the company Helmut Zepf Medizintechnik GmbH, located in Seitingen-Oberflacht, Germany. This extraction forceps is a Class I medical device, meeting the regulatory requirements in force for non-invasive or invasive surgical instruments for temporary use. The manufacturer emphasizes that its products are intended exclusively for healthcare professionals. Compliance maintenance relies on strict adherence to reprocessing cycles (cleaning and sterilization) and on the systematic verification of the physical integrity of the instrument before each surgical act.


State of the art

Surgical medical consumables play a decisive role in operative safety.

Specifications

Manufacturer Helmut Zepf
Tags
Tags
Instrument