The DAVIER. FORME ANGLAISE. FIGURE 35M. - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.

  • Compliance: Medical device Class I.
  • Manufacturer: Helmut Zepf Medizintechnik GmbH.
  • Reference: 12.235.08Z.
  • Reserved for healthcare professionals. Read instructions carefully before use.

133.28 € 133.28 EUR 133.28 € Tax Included

133.28 € Tax Included

(133.28 € / Units)
  • Manufacturer

This combination does not exist.

Instrument

What is the Helmut Zepf extraction forceps figure 35M?

The Helmut Zepf extraction forceps figure 35M is a high-quality manual dental instrument, specifically designed for extraction procedures in oral surgery. Manufactured by Helmut Zepf Medizintechnik GmbH, this English pattern device is crafted from medical stainless steel, ensuring mechanical resistance adapted to the stresses of exodontia. This particular model, identified under reference 12.235.08Z, belongs to the category of reusable consumables after a complete decontamination cycle. Its structure is optimized to provide a secure grip on the tooth or root, facilitating the surgical gesture while respecting the standard clinical protocols of the dental profession.

What are the clinical indications for this instrument?

This forceps is indicated for the manual extraction of teeth and roots. As a manual dental instrument, it is used by dental surgeons and implantologists during avulsion phases. Its use is strictly reserved for qualified healthcare professionals. The manufacturer Helmut Zepf specifies that the primary indication is direct clinical handling in the mouth to remove compromised dental elements. The instrument must be selected according to the morphology of the tooth to be extracted, with figure 35M corresponding to a specific beak configuration for a targeted application in oral surgery.

What are the technical characteristics of the 12.235.08Z extraction forceps?

Technically, this forceps (reference 12.235.08Z) is forged from medical grade stainless steel, a material chosen for its durability properties and its ability to undergo repeated sterilization cycles. It is a Class I device according to medical device regulations. The English pattern design ensures specific ergonomics for the transmission of force during extraction. In accordance with the specifications of the manufacturer Helmut Zepf Medizintechnik GmbH, the product is delivered non-sterile. Its longevity depends on compliance with reprocessing protocols, as no maximum number of cycles is defined, with the end of life being determined by the appearance of visible damage or wear on the edges.

What are the contraindications for the use of this device?

The main contraindication mentioned by the manufacturer Helmut Zepf concerns known hypersensitivity to metals. As the instrument is composed of medical stainless steel, contact with the patient can trigger an intolerance or hypersensitivity reaction. If such a reaction occurs during the procedure, the process must be immediately interrupted and necessary medical measures must be taken. Before any use, the practitioner must check the patient's allergic history to avoid these complications. Furthermore, use is contraindicated on instruments showing cracks, breaks, or visible defects on the cutting edges, as this could compromise patient safety and the effectiveness of the procedure.

What are the maintenance and sterilization precautions?

All Helmut Zepf instruments must imperatively be cleaned, disinfected, and sterilized before the first use, as well as after each subsequent use. The cleaning process must be thorough to ensure the elimination of all biological residues. It is crucial to visually inspect each forceps before use to detect potential damage, such as cracks or excessive wear. The use of damaged or worn products is strictly prohibited. Being a non-sterile device originally, strict adherence to the decontamination chain is the responsibility of the healthcare professional. Compatibility with other products used during the reprocessing cycle must also be verified beforehand to maintain the integrity of the stainless steel.

Who is the manufacturer and what standards are respected?

The extraction forceps is manufactured by Helmut Zepf Medizintechnik GmbH, a company located in Seitingen-Oberflacht, Germany. This medical device is classified as Class I, in accordance with the regulatory requirements applicable to manual dental instruments. The manufacturer ensures the traceability and compliance of its products with European manufacturing standards for medical devices. As a Class I instrument, it meets the safety and performance standards defined for non-invasive or invasive surgical tools for temporary use. The reputation of the Helmut Zepf brand guarantees practitioners a reliable instrument, subject to use and maintenance in accordance with the instructions provided by the manufacturer.