Mesh Plate 75 x 51 x 0.2mm - Jeil Medical
The Plaque en maille 75 x 51 x 0.2mm - Jeil Medical is a medical device manufactured by Jeil Medical Corp..
- Manufacturer: Jeil Medical Corp.
- Reserved for healthcare professionals. Read instructions carefully before use.
| Manufacturer: JEIL MEDICAL |
Complete your order
Our customers often order these together
What is the Jeil Medical 75 x 51 x 0.2mm mesh plate?
The 75 x 51 x 0.2mm mesh plate developed by Jeil Medical is a surgical device used for the reconstruction of bone volumes. It comes in the form of a thin surgical titanium mesh (0.2 mm), offering a balance between rigidity for space maintenance and flexibility for anatomical adaptation. This device acts as a stable physical barrier, allowing the regeneration zone to be delimited while protecting the graft against mechanical pressure from the surrounding soft tissues. Its perforated design facilitates fluid diffusion and vascularization of the surgical site.
What are the clinical indications?
Ce dispositif médical Jeil est principalement indiqué dans les procédures de régénération osseuse guidée (ROG) et de reconstruction alvéolaire. Les chirurgiens oraux et les implantologues l'utilisent pour traiter les défauts osseux complexes, qu'ils soient horizontaux ou verticaux, nécessitant un support structurel significatif. Il est particulièrement utile lors de l'augmentation de la crête alvéolaire avant ou pendant la pose d'implants. En tant que plaque de ROG en titane, il maintient le volume du matériau de comblement (autogreffe ou substitut osseux) tout au long de la phase de cicatrisation osseuse.
What are the technical characteristics?
The technical characteristics of this model include generous dimensions of 75 mm in length by 51 mm in width, allowing it to cover extensive surgical areas or be cut according to the specific needs of the site. The 0.2 mm thickness ensures sufficient thinness to minimize discomfort under mucosal flaps while guaranteeing adequate mechanical strength. Manufactured by Jeil Medical Corp., this plate features a mesh structure that allows for precise handling and stable fixation via osteosynthesis micro-screws not supplied with the device.
What are the contraindications for use?
Contraindications to the use of this mesh plate include clinical situations where an active infection is present at the operative site. Additionally, its use is discouraged in patients with known allergies to the metals constituting the device, although titanium is recognized for its biocompatibility. Uncontrolled systemic pathologies that could compromise bone or mucosal healing, such as unbalanced diabetes or certain metabolic bone diseases, also constitute relative or absolute contraindications to be evaluated by the practitioner before any intervention.
What are the precautions related to its non-resorbable nature?
This mesh plate is a non-resorbable device, meaning it retains its mechanical properties and volume throughout the duration of its implantation. Unlike resorbable membranes, it generally requires a second surgical intervention for its removal once bone consolidation is achieved. The practitioner must ensure hermetic closure of the soft tissues to avoid any early exposure of the surgical titanium mesh, which could lead to bacterial contamination of the graft site. Regular post-operative monitoring is essential to check for the absence of dehiscence.
Who is the manufacturer and what standards are met?
The device is manufactured by Jeil Medical Corp., a recognized manufacturer in the field of osteosynthesis and implantable solutions. Regarding regulatory standards, the risk class and specific CE marking are not mentioned in the current technical data for this CONSO category product. It is the responsibility of the healthcare professional to systematically consult the instructions for use and product labeling provided by Jeil Medical before any implantation to verify the certifications in force and the sterilization or handling protocols recommended by the manufacturer.
State of the art
Surgical medical consumables play a decisive role in operative safety.