Dental extraction forceps for upper incisors and canines, Exlog pattern Figure 34N - Helmut Zepf (15.234.07D) - Delynov
The Davier d'extraction dentaire pour incisives et canines supérieures, modèle Exlog figure 34N - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.
- Manufacturer: Helmut Zepf Medizintechnik GmbH.
- Reference: 15.234.07D.
- Reserved for healthcare professionals. Read instructions carefully before use.
What is the Exlog figure 34N Helmut Zepf extraction forceps?
The dental extraction forceps for upper incisors and canines, model Exlog figure 34N, is a manual oral surgery instrument developed by Helmut Zepf Medizintechnik GmbH. This device, identified under reference 15.234.07D, is specifically structured to adapt to the anatomy of single-rooted teeth of the upper arch. Its design is based on an articulated architecture allowing optimal transmission of force from the practitioner to the instrument's beaks, thus ensuring a firm grip on the neck of the tooth. As part of the Exlog range, it benefits from Helmut Zepf's expertise in manufacturing precision instruments for dentistry.
What are the clinical indications for this forceps?
The use of this upper canine and incisor forceps is indicated for dental avulsion procedures in the maxilla. In clinical practice, it is used for the extraction of teeth numbers 11, 12, 13, 21, 22, and 23. Its use occurs after syndesmotomy, allowing for the luxation and final extraction of the tooth from its socket. This instrument is particularly requested during conventional exodontia surgeries, site preparations for immediate implant placement, or for the elimination of infectious foci of dental origin located in the upper anterior sector.
What are the technical characteristics of the 15.234.07D instrument?
The Helmut Zepf reference 15.234.07D forceps is distinguished by its figure 34N morphology, adapted to upper incisors and canines. The geometry of the beaks is designed to follow the convexity of the vestibular and palatal surfaces of these specific teeth, guaranteeing maximum stability during rotation and traction movements. The Exlog design integrates ergonomics facilitating repeated handling in the dental office. Each technical detail aims to ensure controlled force transmission, minimizing the risk of root fracture or damage to surrounding bone tissue during extraction.
What are the contraindications for the use of this device?
Contraindications for the use of the Helmut Zepf extraction forceps are mainly related to the limits of closed exodontia. The use of this instrument is prohibited if the tooth presents such coronal destruction that a solid grip on the neck is impossible, then requiring a surgical approach by alveolectomy. Similarly, it must not be used on multi-rooted teeth or on the mandibular arch, as its curvature and the shape of its beaks are not compatible with the anatomy of these sectors. The practitioner must also evaluate general contraindications related to the patient's health status before any surgical intervention.
What are the maintenance precautions for this non-absorbable forceps?
As a reusable metallic instrument, the Helmut Zepf forceps requires a rigorous decontamination and sterilization protocol after each use. Precautions include pre-disinfectant cleaning, ideally by ultrasound, followed by thorough rinsing to remove any organic or chemical residue. Sterilization must be carried out in a steam autoclave according to the standard cycles validated by the manufacturer. It is essential to check for the absence of corrosion or excessive play in the joint before each intervention to guarantee patient safety and the effectiveness of the surgical procedure.
Who is the manufacturer and what standards are respected?
This device is manufactured by Helmut Zepf Medizintechnik GmbH, a recognized manufacturer in the field of high-precision dental and surgical instrumentation. Although the specific regulatory class and CE marking are not detailed in the technical documentation provided for this reference 15.234.07D, Helmut Zepf products are generally designed according to German industrial quality standards. To obtain details on the exact certifications or specific ISO standards applied to this Exlog figure 34N model, it is recommended to refer to the instructions for use or the declaration of conformity provided by the manufacturer with the instrument.
State of the art
Surgical medical consumables play a decisive role in operative safety.
Specifications
| Manufacturer | Helmut Zepf |