Exlog dental extraction forceps Figure 34M for upper incisors and canines - Helmut Zepf (15.234.08) - Delynov

https://www.delynov.fr/web/image/product.template/170844/image_1920?unique=42f1e40

The Davier Exlog Figure 34M pour incisives et canines supérieures - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.

  • Manufacturer: Helmut Zepf Medizintechnik GmbH.
  • Reference: 15.234.08.
  • Reserved for healthcare professionals. Read instructions carefully before use.

177.46 € 177.46 EUR 177.46 € Tax Included

177.46 € Tax Included

(0.00 € / Units)
  • Manufacturer

This combination does not exist.

Instrument

What is the Exlog Figure 34M Helmut Zepf forceps?

The Exlog Figure 34M forceps is a manual oral surgery instrument developed by the manufacturer Helmut Zepf Medizintechnik GmbH. This device is specifically configured for the extraction of anterior teeth from the upper arch. Its structure, identified under technical reference 15.234.08, belongs to the Exlog range, characterized by a design adapted to the requirements of modern clinical practice. This instrument is used to firmly grasp the dental crown in order to perform the luxation and rotation movements necessary for avulsion. As a product of the Helmut Zepf brand, it benefits from the expertise of a manufacturer recognized in the field of high-precision surgical instrumentation for dental offices and specialized hospital centers.

What are the clinical indications for this upper incisor and canine forceps?

The Figure 34M upper incisor canine forceps is indicated exclusively for exodontia procedures in the maxilla. Its primary application concerns the extraction of central incisors, lateral incisors, and upper canines. The shape of the beaks is designed to adapt to the cervical anatomy of these single-rooted teeth, allowing for a stable and secure grip. This device is used by the dental surgeon or oral surgeon during simple or complex avulsion procedures, particularly before implant placement or to treat advanced carious and periodontal pathologies. The use of this Helmut Zepf forceps guarantees optimal force transmission during alveolar release maneuvers.

What are the technical characteristics of the 15.234.08 model?

Model 15.234.08, corresponding to the Exlog Figure 34M forceps, presents technical specifications specific to the extraction of upper anterior teeth. Its morphology is straight, which is the standard for unobstructed access to the upper incisors and canines. Unlike models intended for posterior sectors, this forceps does not feature a marked angled curvature, facilitating alignment with the long axis of the root. The Exlog design by Helmut Zepf aims to provide an effective gripping interface for the practitioner. Although specific details on the alloy are not provided in the source documentation, this type of instrumentation is traditionally designed to withstand repeated autoclave sterilization cycles, thus ensuring maintenance in accordance with the hygiene protocols in force in healthcare facilities.

What are the contraindications for the use of this instrument?

Contraindications for the use of the Exlog Figure 34M forceps are mainly related to the dental anatomy and the patient's clinical status. This instrument is not suitable for the extraction of premolars or molars, nor for teeth in the mandibular arch, due to its straight configuration specific to upper anterior teeth. Its use is also prohibited if the patient presents uncontrolled general contraindications to oral surgery. Technically, using a forceps unsuitable for the tooth's morphology can lead to root fractures or damage to the alveolar bone tissues. Reference should systematically be made to the recommendations of the manufacturer Helmut Zepf and the feasibility of extraction should be evaluated by a prior radiological examination.

What are the maintenance precautions for this non-resorbable device?

As a reusable and non-resorbable metallic surgical instrument, the Figure 34M forceps requires a rigorous decontamination and sterilization protocol after each use. Precautions include pre-disinfectant cleaning, followed by manual or ultrasonic cleaning to remove organic debris in the hinge and beak areas. Drying must be meticulous to avoid any risk of corrosion before packaging in a sterilization pouch. Sterilization is generally carried out by moist heat (autoclave) according to the parameters validated by the manufacturer Helmut Zepf Medizintechnik GmbH. Regular maintenance of the joints with a lubricant suitable for surgical instruments is recommended to maintain fluidity of movement and extend the operational life of the device.

Who is the manufacturer and what standards are respected?

The official manufacturer of this device is Helmut Zepf Medizintechnik GmbH, a German entity specializing in the production of high-quality surgical instruments. Although the precise regulatory class and CE marking are not explicitly mentioned in the provided source data, Helmut Zepf products are developed according to strict industrial standards to meet the requirements of healthcare professionals. As a medical device used in invasive surgery, this forceps is subject to local and international regulations governing reusable surgical instruments. For any specific information concerning MDR compliance or ISO certifications applicable to reference 15.234.08, it is recommended to consult the official technical documentation provided by the manufacturer or to contact Delynov support.


State of the art

Surgical medical consumables play a decisive role in operative safety.

Specifications

Manufacturer Helmut Zepf