Skip to Content

Winter dental root elevator right side figure 12-R - Helmut Zepf (17.337.16) - Delynov

https://www.delynov.fr/web/image/product.template/170909/image_1920?unique=50028cb

The Élévateur de racines dentaires Winter côté droit figure 12-R - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.

  • Manufacturer: Helmut Zepf Medizintechnik GmbH.
  • Reference: 17.337.16.
  • Reserved for healthcare professionals. Read instructions carefully before use.

61.38 € 61.38 EUR 61.38 € Tax Included

61.38 € Tax Included

(0.00 € / Units)
  • Manufacturer

This combination does not exist.

Instrument

What is the winter root elevator right side figure 12-R - Helmut Zepf?

The winter root elevator right side figure 12-R is a specialized oral surgery instrument designed by the manufacturer Helmut Zepf Medizintechnik GmbH. This device is characterized by a robust structure with an ergonomic handle and an angled working part, specifically oriented for use on the right side of the jaw. Referenced under code 17.337.16, this instrument is a tool of choice for dental surgeons and implantologists requiring a powerful and precise lever for root extractions. Its design allows for a stable grip, essential for applying the necessary forces during alveolar surgery procedures.

What are the clinical indications for this Helmut Zepf instrument?

This Helmut Zepf instrument is primarily indicated for the extraction of dental roots or radicular fragments, particularly in the area of mandibular molars. Its use is recommended during avulsion surgeries where conventional forceps methods are insufficient to mobilize the root. The winter root elevator is used to luxate the tooth or debris by leveraging against the surrounding alveolar bone, thus facilitating the release of structures without excessively damaging adjacent tissues. It is particularly suitable for cases of fractured or deeply embedded roots requiring a lateral lever approach specific to the right side.

What are the technical characteristics of model 17.337.16?

The Helmut Zepf elevator, bearing technical reference 17.337.16, features characteristics specific to figure 12-R. It has a blade oriented to the right, designed to insert effectively into the periodontal or alveolar space. The geometry of the instrument is optimized to transmit significant leverage force while maintaining rigorous tactile control. The handle is sized to offer maximum contact surface with the practitioner's palm, thereby reducing fatigue during prolonged interventions. The junction between the shank and the active part is reinforced to resist the high mechanical stresses inherent in root luxation maneuvers in oral surgery.

What are the contraindications for the use of this elevator?

Contraindications for the use of the winter root elevator include all clinical situations where the application of leverage force could compromise sensitive anatomical structures, such as the inferior alveolar canal or the maxillary sinus, depending on the proximity of the roots. It must not be used if the supporting alveolar bone is too fragile or presents a pathology that does not allow for secure support. Furthermore, as with any metallic instrument, its use is contraindicated in patients with a known hypersensitivity to the metals constituting the alloy, although this is rare with high-quality surgical steels. The practitioner must assess bone density before any application of force.

What are the maintenance and durability precautions?

As a non-resorbable and reusable instrument, this Helmut Zepf elevator requires a strict sterilization protocol between each patient. It is imperative to follow the recommendations of the manufacturer Helmut Zepf Medizintechnik GmbH regarding cleaning, decontamination, and autoclaving. To preserve the integrity of the working part and prevent corrosion, neutral pH cleaning solutions should be used, and aggressive chemical agents should be avoided. Regular inspection of the tip and shank is advised to detect any micro-cracks or deformation resulting from excessive stress. Proper maintenance guarantees the longevity of the instrument and the safety of surgical procedures.

Who is the manufacturer and what standards are respected?

The device is manufactured by Helmut Zepf Medizintechnik GmbH, a recognized manufacturer in the field of surgical and dental instrumentation. Although the specific regulatory class and CE marking are not detailed in the current technical sheet, products from this brand are generally designed according to the rigorous quality standards of the German medical industry. Practitioners are invited to consult the instructions for use and product labeling to verify current certifications and specific safety instructions related to the European Medical Device Regulation (MDR). Traceability is ensured by the reference 17.337.16 specific to the Helmut Zepf catalog.


State of the art

Specialized surgical instrumentation is evolving towards ergonomic designs.

Specifications

Manufacturer Helmut Zepf
Tags
Tags
Instrument