Skip to Content

Buffer holders - Helmut Zepf (19.600.25) - Delynov

https://www.delynov.fr/web/image/product.template/9919/image_1920?unique=1f8eb20

The Porte-tampons - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.

  • Compliance: Medical device Class I.
  • Manufacturer: Helmut Zepf Medizintechnik GmbH.
  • Reference: 19.600.25.
  • Reserved for healthcare professionals. Read instructions carefully before use.

35.60 € 35.6 EUR 35.60 € Tax Included

35.60 € Tax Included

(35.60 € / Units)
  • Manufacturer

This combination does not exist.

Instrument

What is the Helmut Zepf sponge holder (19.600.25)?

The Helmut Zepf sponge holder, referenced under code 19.600.25, is a specialized manual instrument used in dental and oral surgery. Manufactured by Helmut Zepf Medizintechnik GmbH, this device is designed in high-quality medical stainless steel. Its structure is specifically studied to offer a reliable and stable grip of gauze or cotton swabs. As an instrument in the CONSO category, it meets the durability requirements necessary for repeated clinical procedures. This surgical sponge holder is an essential tool for maintaining the asepsis of the surgical field by allowing the manipulation of sterile consumables without direct contact, thus limiting the risk of cross-contamination.

What are the clinical indications for this surgical sponge holder?

This surgical sponge holder is indicated for a multitude of procedures in oral, implant, and periodontal surgery. Its primary use lies in the management of exudate and bleeding through the application of absorbent swabs to extraction sites or incision areas. It is also used for preoperative disinfection of mucous membranes by applying antiseptic agents. In implantology, the sponge holder forceps allows for gentle cleaning of the site before implant placement or to stabilize a membrane if necessary through indirect pressure. Its design allows it to reach the posterior sectors of the oral cavity with increased precision, ensuring that the practitioner maintains optimal visibility throughout the intervention.

What are the technical characteristics of the device?

The Helmut Zepf sponge holder (19.600.25) is distinguished by its medical stainless steel construction, guaranteeing high resistance to corrosion and sterilization cycles. Although specific dimensions are not detailed, its ergonomic design is intended for easy handling by healthcare professionals. This device is classified as a Class I manual dental instrument according to current regulations. It is delivered non-sterile by the manufacturer Helmut Zepf Medizintechnik GmbH, which requires a rigorous processing protocol before the first use. The quality of the jaw fit ensures firm retention of the swab, preventing any accidental slipping during critical phases of surgery.

What are the contraindications for the use of this instrument?

The main contraindication for the use of this sponge holder lies in the patient's known hypersensitivity to metallic components, specifically stainless steel. A hypersensitivity reaction or metal intolerance can be triggered upon contact of the instrument with the tissues. The manufacturer Helmut Zepf specifies that if such a reaction occurs during the procedure, the intervention must be immediately interrupted and necessary medical measures must be taken. It is therefore recommended to check the patient's allergic history before any use. Apart from these specific cases of allergy, the instrument does not present major clinical contraindications when used by a qualified professional.

What are the maintenance and sterilization precautions?

Like any non-sterile surgical instrument, the sponge holder must imperatively be cleaned, disinfected, and sterilized before its first use, as well as after each subsequent use. The reprocessing process must be complete to guarantee patient safety. Before each cycle, the practitioner must visually inspect the instrument to detect any damage such as cracks, breaks, or defects on the gripping surfaces. It is strictly advised against using a damaged or worn product. Due to its robust stainless steel design, there is no defined maximum limit for processing cycles, but natural wear must be monitored by the healthcare professional to ensure the maintenance of the forceps' performance.

Who is the manufacturer and what standards are respected?

The device is manufactured by Helmut Zepf Medizintechnik GmbH, a recognized manufacturer located in Seitingen-Oberflacht, Germany. This sponge holder is a Class I medical device, compliant with regulatory requirements for manual dental instruments. Compliance with Helmut Zepf's rigorous manufacturing protocols ensures the traceability and conformity of the product for professional use in dental offices or hospital environments. The instrument must be used exclusively by trained healthcare professionals. Reference 19.600.25 allows for precise identification of the model within the brand's range of surgical instruments, thus ensuring perfect compatibility with current sterilization and maintenance standards.


State of the art

Surgical medical consumables play a decisive role in operative safety.

Specifications

Manufacturer Helmut Zepf
Tags
Tags
Instrument