Trephine RAL - JOTA (229RF.RAL.080) - Delynov
The Trephine RAL - JOTA is a medical device manufactured by le fabricant, Class IIa, CE marking CE0483.
- Compliance: Medical device Class IIa, CE marking CE0483.
- Manufacturer: le fabricant.
- Reference: 229RF.RAL.080.
- Reserved for healthcare professionals. Read instructions carefully before use.
| Manufacturer: JOTA Professional Rotary Instruments |
Complete your order
Our customers often order these together
What is the RAL 229RF.RAL.080 trephine?
The RAL trephine, referenced under code 229RF.RAL.080 by the JOTA brand, is a rotary cutting instrument intended for bone surgery. This Class IIa medical device consists of a metallic structure designed for bone core harvesting or circular drilling. As a trephine bur, it is delivered non-sterile and requires a complete processing protocol before its first use. The manufacturer JOTA AG specifies that these instruments are reusable, subject to rigorous inspection by the practitioner. Its design allows for precise penetration into mineralized tissues for implantology or oral reconstructive surgery needs.
Quelles sont les indications cliniques de cette tréphine de chirurgie orale ?
Ce trépan de chirurgie orale est destiné aux interventions nécessitant une excision osseuse circulaire. Il est indiqué pour le prélèvement osseux autogène, la création de sites implantaires spécifiques, ou l'extraction de fragments osseux. L'instrument est classé semi-critique. Son application clinique est strictement réservée aux experts et praticiens qui doivent évaluer l'état de l'instrument avant chaque procédure. Le trépan est un outil clé pour les chirurgiens oraux réalisant des greffes osseuses ou des explantations, assurant une coupe nette grâce à sa géométrie optimisée pour les tissus durs.
What are the technical characteristics of the JOTA trephine?
The RAL trephine (229RF.RAL.080) from the JOTA brand meets the requirements of the CE0483 marking. It is manufactured from metallic materials resistant to repeated sterilization cycles. Technical specifications impose rigorous maintenance: cleaning can be performed by ultrasound with non-foaming agents, strictly respecting the concentrations and temperatures recommended by the detergent manufacturer. The use of demineralized or low-contamination sterile water (max. 10 germs/ml) is required for rinsing. Its durability depends directly on the absence of excessive stress and compliance with validated reprocessing parameters to maintain its initial cutting performance.
What are the contraindications for the use of this device?
The major contraindications lie in the use of an instrument showing signs of wear, corrosion, or potential breakage. The manufacturer JOTA AG emphasizes that the physician is solely responsible for the decision to reuse the product. In case of doubt regarding the integrity of the trephine bur, it is imperative to dispose of it prematurely to avoid any risk of failure. Furthermore, use is prohibited if validated sterilization and disinfection conditions cannot be guaranteed, or if the specific product labeling contains contradictory information regarding its reuse.
What are the precautions related to reuse and maintenance?
La tréphine de marque JOTA est réutilisable, mais sa longévité dépend de l'expertise du praticien. Un nettoyage et une désinfection efficaces sont des conditions indispensables à une stérilisation réussie. Il est crucial d'utiliser des dispositifs d'entretien (laveur-désinfecteur, stérilisateur) qui sont régulièrement contrôlés. Évitez toute contamination et utilisez uniquement des solutions fraîchement préparées. La résistance du matériau doit être vérifiée par rapport aux détergents utilisés. Si l'instrument présente des signes de fatigue ou si sa capacité de coupe est altérée, il doit être remplacé immédiatement pour assurer une sécurité maximale du patient lors des procédures de chirurgie orale.
Who is the manufacturer and what standards are met?
Le fabricant officiel de ce dispositif est JOTA AG, situé à Rüthi, Suisse. Ce produit est certifié Classe IIa et porte le marquage CE0483, garantissant sa conformité aux exigences réglementaires européennes pour les dispositifs médicaux. JOTA AG fournit des instructions de retraitement strictes qui s'appliquent à toute sa gamme distribuée. La responsabilité de la stérilité des instruments incombe à l'utilisateur, qui doit mettre en œuvre des procédures validées. Le respect de ces normes internationales assure que la tréphine conserve ses propriétés mécaniques et sa sécurité d'utilisation tout au long de son cycle de vie en chirurgie orale ou en milieu hospitalier.
State of the art
Surgical medical consumables play a decisive role in operative safety.