Rochester Pean Forceps - Helmut Zepf (23.106.16)
The PEAN ROCHESTER PINCE - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.
- Compliance: Medical device Class I.
- Manufacturer: Helmut Zepf Medizintechnik GmbH.
- Reference: 23.106.16.
- Reserved for healthcare professionals. Read instructions carefully before use.
| Manufacturer: Helmut Zepf |
Complete your order
Our customers often order these together
What is the Pean Rochester forceps?
La pince Pean Rochester, référencée sous le code 23.106.16, est un instrument chirurgical manuel de haute précision. Conçue en acier inoxydable de qualité médicale, elle appartient à la catégorie des instruments de Régénération Osseuse Guidée (ROG) et de chirurgie générale. Sa structure robuste est spécifiquement adaptée pour répondre aux exigences de la pratique clinique en chirurgie orale et en milieu hospitalier. En tant que pince chirurgicale Rochester Pean, elle offre une préhension fiable grâce à ses mors travaillés, permettant aux praticiens de manipuler les tissus ou les dispositifs médicaux avec une grande stabilité lors des interventions invasives.
What are the clinical indications?
Cette pince hémostatique de Rochester est indiquée pour diverses procédures de chirurgie orale, notamment en implantologie et parodontologie. Son utilisation principale est l'hémostase par clampage des vaisseaux, mais elle est également sollicitée pour saisir et maintenir les tissus mous, les membranes ou le matériel de suture. C'est un instrument manuel destiné exclusivement aux professionnels de santé. Elle intervient efficacement dans les protocoles de chirurgie pré-implantaire où la gestion des lambeaux et le contrôle du champ opératoire sont critiques pour le succès de la régénération tissulaire.
What are the technical characteristics?
The Pean Rochester forceps (reference 23.106.16) is distinguished by its manufacture in high-quality medical stainless steel, guaranteeing resistance to repeated sterilization cycles. Although delivered non-sterile, its design allows for complete reprocessing including cleaning, disinfection, and sterilization before each use. Due to its metallic nature, particular attention must be paid to the surface condition of the instrument. The practitioner must check for the absence of visible damage such as cracks, breaks, or defects on the active parts before any intervention. Its technical configuration is optimized for ergonomic handling in restricted oral environments.
What are the contraindications for use?
The main medical contraindication documented by Helmut Zepf Medizintechnik GmbH concerns known hypersensitivity or intolerance to metals, specifically medical stainless steel. If an allergic reaction or hypersensitivity manifests in the patient upon contact with the instrument, the procedure must be immediately interrupted and necessary medical measures must be taken. Furthermore, the use of the instrument is strictly prohibited if it shows visible signs of wear, cracks, or damaged cutting edges, as this could compromise patient safety and the effectiveness of the surgical procedure.
What are the maintenance and reprocessing precautions?
Comme tout instrument chirurgical, la pince hémostatique Rochester doit impérativement être nettoyée, désinfectée et stérilisée avant sa première utilisation et après chaque utilisation ultérieure. Les produits Helmut Zepf sont livrés non stériles. Le processus de retraitement doit suivre les protocoles de stérilisation à la vapeur standard. Grâce à sa conception robuste et aux matériaux utilisés, il n'y a pas de limite maximale définie de cycles de traitement, tant que l'instrument ne présente pas de dégradation fonctionnelle ou structurelle. Il est crucial de valider la compatibilité avec les autres produits utilisés simultanément lors de la chirurgie.
Who is the manufacturer and what standards are respected?
The forceps is manufactured by Helmut Zepf Medizintechnik GmbH, a recognized manufacturer located in Seitingen-Oberflacht, Germany. This medical device is classified as Class I (Class Ir according to certain reprocessing specifications), in accordance with current medical device regulations. Compliance with manufacturing standards ensures that the stainless steel used meets medical use requirements. As a Class I device, it meets essential safety and performance requirements. The use of this instrument is strictly reserved for qualified healthcare professionals, thus guaranteeing an application in accordance with the rules of surgical art.
State of the art
Guided bone regeneration (GBR) in implantology relies on membrane fixation quality.