Skip to Content
The Delynov team is away and back on 24 August. Your parcels will be processed with longer lead times.

Non-Magnifying Mouth Mirror Helmut Zepf (24.061.24) - Delynov Delynov

https://www.delynov.fr/web/image/product.template/11899/image_1920?unique=1e16225

The Miroir à bouche non grossissant Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.

  • Compliance: Medical device Class I.
  • Manufacturer: Helmut Zepf Medizintechnik GmbH.
  • Reference: 24.061.24.
  • Reserved for healthcare professionals. Read instructions carefully before use.

41.93 € 41.93 EUR 41.93 € Tax Included 105.12 €

41.93 € Tax Included 105.12 €

(0.00 € / Units)
  • Manufacturer

This combination does not exist.

Instrument

What is the Helmut Zepf mouth mirror (24.061.24)?

The Helmut Zepf mouth mirror, referenced under code 24.061.24, is a non-magnifying examination instrument designed for daily clinical practice. Manufactured in medical stainless steel by Helmut Zepf Medizintechnik GmbH, this device is a fundamental piece of rotary and manual instrumentation. Its structure is specifically studied to offer clear reflection without distortion, thus facilitating the exploration of oral cavities. This dental mouth mirror is delivered non-sterile and requires a complete cleaning, disinfection, and sterilization protocol before its first use and between each patient, in accordance with the manufacturer's guidelines to guarantee optimal safety of use in dental offices or hospital environments.

What are the clinical indications for this dental mouth mirror?

This dental mouth mirror is primarily indicated for the visual intra-oral inspection of areas that cannot be seen directly by the practitioner. In oral surgery, implantology, and periodontology, it serves as an essential diagnostic tool to evaluate the condition of soft tissues, dental structures, and surgical sites. It allows for the precise visualization of distal, lingual, or palatal surfaces. The use of this Helmut Zepf device is strictly reserved for qualified healthcare professionals. Its role is decisive during preliminary examinations, allowing for the detection of pathologies or the planning of complex interventions by offering indispensable indirect visibility in restricted access areas of the oral cavity.

What are the technical characteristics of model 24.061.24?

The Helmut Zepf mouth mirror (reference 24.061.24) is characterized by a non-magnifying design, ensuring an image faithful to the real dimensions of the observed structures. Manufactured by Helmut Zepf Medizintechnik GmbH, it is composed of medical stainless steel, a material chosen for its resistance to repeated reprocessing cycles. Although there is no defined maximum limit for the number of sterilization cycles due to its robust design, the practitioner must imperatively check for the absence of visible damage such as cracks, breaks, or defects on the surfaces before each use. This Class I device must be maintained according to rigorous cleaning and disinfection protocols to maintain its optical and mechanical properties.

What are the contraindications for the use of this instrument?

The main medical contraindication for the use of this mouth mirror concerns patients with a known intolerance or hypersensitivity to metals, and more particularly to the components of medical stainless steel. A hypersensitivity reaction may be triggered upon contact of the instrument with the mucous membranes. The manufacturer specifies that if such an intolerance reaction occurs during the examination or intervention, the procedure must be immediately stopped and the necessary medical measures must be taken. It is therefore recommended to check the patient's allergic history before any manipulation. Apart from this specific sensitivity, the instrument does not present documented clinical contraindications, subject to compliant maintenance.

What are the maintenance and sterilization precautions?

Helmut Zepf products are delivered non-sterile. Before the first use, as well as before each subsequent use, the mouth mirror must imperatively be cleaned, disinfected, and sterilized. The reprocessing process must be complete to eliminate any risk of cross-contamination. It is crucial to inspect the instrument for any visible wear or structural damage before use. Never use a mirror with damaged edges or an altered reflective surface. Compatibility with other cleaning and disinfection products must be verified beforehand. Due to the use of high-quality stainless steel, the device supports standard autoclave sterilization cycles, although the lifespan depends directly on compliance with the manufacturer's maintenance instructions.

Who is the manufacturer and what standards are respected?

This mouth mirror is manufactured by Helmut Zepf Medizintechnik GmbH, a company located in Seitingen-Oberflacht, Germany. This medical device belongs to Class I according to current regulations. The manufacturer ensures the compliance of its instruments with safety and performance requirements. Compliance with rigorous manufacturing protocols by Helmut Zepf guarantees a reliable instrument for dental professionals. As a Class I device, it meets the quality standards required for non-invasive diagnostic instruments. Users must refer to the instructions provided by the manufacturer to ensure the maintenance of product compliance throughout its use cycle in a clinical environment.


State of the art

Specialized surgical instrumentation is evolving towards ergonomic designs.

Specifications

Manufacturer Helmut Zepf
Tags
Tags
Instrument