Skip to Content

The product title in English would be: Scissors-Burins CH Fedi 1 - Helmut Zepf (24.493.01) - Delynov

https://www.delynov.fr/web/image/product.template/18106/image_1920?unique=7c4c9d4

The Ciseaux-Burins CH Fedi 1 - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.

  • Compliance: Medical device Class I.
  • Manufacturer: Helmut Zepf Medizintechnik GmbH.
  • Reference: 24.493.01.
  • Reserved for healthcare professionals. Read instructions carefully before use.

62.32 € 62.32 EUR 62.32 € Tax Included

62.32 € Tax Included

(62.32 € / Units)
  • Manufacturer

This combination does not exist.

Instrument

What is the CH Fedi 1 chisel-chisel?

The CH Fedi 1 chisel-chisel, referenced under code 24.493.01, is a specialized manual instrument designed by the manufacturer Helmut Zepf Medizintechnik GmbH. This device is manufactured from medical stainless steel, a standard material for surgical instrumentation due to its resistance to reprocessing procedures. As an instrument from the Helmut Zepf range, it is intended for professional use in dental offices or hospital settings for oral surgery procedures. Its structure is specifically adapted to the needs of periodontology and implantology for hard tissue work.

What are the clinical indications?

This fedi chisel-chisel is indicated for manual dental surgery procedures. It is primarily used for bone resection, remodeling of alveolar contours, and hard tissue management during periodontal or pre-implant surgeries. The fedi chisel allows the practitioner to perform precise cutting and scraping actions on the bone. It is essential for regularizing bone surfaces after an extraction or for preparing a site before implant placement. Its use is strictly reserved for qualified healthcare professionals mastering oral surgery techniques.

What are the technical characteristics?

The CH Fedi 1 chisel-chisel (reference 24.493.01) is a non-sterile instrument upon delivery by Helmut Zepf. It is designed from high-quality medical stainless steel to ensure consistent performance during interventions. Its monobloc design allows for direct force transmission during manual use. Before any use, the practitioner must imperatively check for the absence of visible damage such as cracks, breaks, or defects on the cutting edges. The integrity of the instrument is crucial to guarantee patient safety and the effectiveness of the surgical procedure.

What are the contraindications for use?

The main contraindication mentioned by the manufacturer Helmut Zepf concerns metal intolerance. A hypersensitivity reaction or an allergy to the components of the medical stainless steel may occur upon contact with the instrument. If such a reaction manifests in the patient during the intervention, the procedure must be immediately stopped and necessary medical measures must be taken. It is therefore recommended to check the patient's allergic history before any manipulation. Furthermore, the use of an instrument showing signs of wear, corrosion, or blunt cutting edges is prohibited.

What are the maintenance and sterilization precautions?

Like all Helmut Zepf Medizintechnik GmbH products, this instrument is delivered non-sterile. It must imperatively undergo a complete cycle of cleaning, disinfection, and sterilization before the first use, as well as after each subsequent use. Cleaning must be meticulous to eliminate all biological residues. Although there is no defined maximum limit for processing cycles due to the robustness of the materials, the instrument must be inspected regularly. Any sign of physical degradation, such as cracks or marked wear of the active parts, requires the immediate removal of the device from the clinical circuit.

Who is the manufacturer and what standards are met?

The CH Fedi 1 chisel-chisel is manufactured by Helmut Zepf Medizintechnik GmbH, located in Seitingen-Oberflacht, Germany. This medical device belongs to Class I (Class Ir according to reprocessing mentions). The manufacturer guarantees the compliance of its instruments with the regulatory requirements applicable to manual medical devices. As a Class I product, it meets the safety and performance standards for reusable surgical instruments. Traceability is ensured by the technical reference 24.493.01, allowing for rigorous tracking of the equipment within the practice's surgical arsenal.


State of the art

Specialized surgical instrumentation is evolving towards ergonomic designs.

Specifications

Manufacturer Helmut Zepf
Tags
Tags
Instrument