Burins for oral surgery and implantology - Helmut Zepf (24.493.03) - Delynov
The Burins pour chirurgie orale et implantologie - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.
- Compliance: Medical device Class I.
- Manufacturer: Helmut Zepf Medizintechnik GmbH.
- Reference: 24.493.03.
- Reserved for healthcare professionals. Read instructions carefully before use.
| Manufacturer: Helmut Zepf |
Complete your order
Our customers often order these together
What is the Helmut Zepf (24.493.03) oral surgery chisel?
The Helmut Zepf oral surgery chisel, referenced under code 24.493.03, is a specialized manual instrument for hard tissue work. Manufactured from medical stainless steel by Helmut Zepf Medizintechnik GmbH, this device is designed to withstand mechanical stress during bone cutting phases. Its rigid structure and specific design allow for efficient force transmission during clinical use. This equipment is delivered non-sterile and requires a complete cleaning and sterilization protocol before its first use in the office or operating room.
What are the clinical indications for this chisel in implantology?
In clinical practice, this implantology chisel is indicated for various bone surgery maneuvers. It is primarily used for the resection of exostoses, harvesting autogenous bone chips, or remodeling the alveolar ridge before implant placement. In oral surgery, it also facilitates root separation or the removal of obstructing bone walls during complex tooth extractions. Its use is strictly reserved for qualified healthcare professionals mastering manual bone surgery techniques.
What are the technical characteristics of model 24.493.03?
The Helmut Zepf model 24.493.03 is characterized by its high-quality medical stainless steel composition, ensuring compatibility with repeated sterilization cycles. As a Class I instrument, it meets the safety requirements for non-invasive or temporary-use invasive medical devices. Although no maximum processing cycle limit is defined by the manufacturer due to its robust design, the instrument must be inspected before each use for visible damage such as cracks, breaks, or wear of the cutting edges.
What are the contraindications for the use of this instrument?
La principale contre-indication médicale concerne l'hypersensibilité ou l'intolérance connue aux métaux, spécifiquement l'acier inoxydable. En cas de réaction allergique ou d'intolérance chez le patient au contact de l'instrument, la procédure chirurgicale doit être immédiatement interrompue et des mesures médicales appropriées doivent être prises. Il est donc recommandé de vérifier les antécédents allergiques du patient avant toute intervention impliquant ce dispositif.
What are the maintenance and reprocessing precautions?
Before the first use and after each intervention, the chisel must undergo a complete cleaning, disinfection, and sterilization cycle. Since it is delivered non-sterile, compliance with these steps is crucial for patient safety. The practitioner must verify the integrity of the instrument, particularly the absence of defects on the sharp edges. The use of damaged products or those showing marked signs of wear is prohibited. Compatibility with other cleaning and disinfection products must also be validated beforehand by the user.
Who is the manufacturer and what standards are met?
L'instrument est fabriqué par Helmut Zepf Medizintechnik GmbH, une entreprise reconnue située à Seitingen-Oberflacht, Allemagne. Ce ciseau est classé comme dispositif médical de Classe I selon la réglementation en vigueur. L'utilisation de cet instrument manuel est strictement réservée aux professionnels de santé. Le respect des protocoles de retraitement et l'inspection visuelle garantissent la conformité de l'instrument aux exigences de sécurité pour la chirurgie orale et l'implantologie.
State of the art
Surgical medical consumables play a decisive role in operative safety.