The Porte-empreinte Figurine 0 - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.

  • Compliance: Medical device Class I.
  • Manufacturer: Helmut Zepf Medizintechnik GmbH.
  • Reference: 28.601.00.
  • Reserved for healthcare professionals. Read instructions carefully before use.

40.28 € 40.28 EUR 40.28 € Tax Included

40.28 € Tax Included

(40.28 € / Units)
  • Manufacturer

This combination does not exist.

Instrument

What is the Helmut Zepf Figurine 0 impression tray?

The Figurine 0 impression tray (reference 28.601.00) is a manual instrument designed by Helmut Zepf Medizintechnik GmbH. It is a stainless steel impression tray made of medical grade stainless steel, intended to support the impression material during the negative reproduction of oral structures. Its specific dimension, designated by the name Figurine 0, makes it a tool adapted to narrow morphologies or specific cases requiring reduced bulk in the mouth. As a reusable instrument, it is designed to withstand repeated cleaning and sterilization cycles, thus guaranteeing a longevity consistent with the requirements of dental surgery and implantology practices.

What are the clinical indications?

This device is indicated for all impression-taking procedures requiring a rigid and stable support. In oral and prosthetic surgery, it allows for the delivery of materials (alginates, silicones, or polyethers) to obtain a faithful replica of the arches. Its small size allows it to be used as a pediatric impression tray or for partial sectors in adults when mouth opening is limited or the anatomy is narrow. It serves as a fundamental base for the creation of study models, implant planning, or the fabrication of prostheses. Its use is strictly reserved for qualified healthcare professionals mastering conventional impression-taking techniques.

What are the technical characteristics?

The Helmut Zepf impression tray reference 28.601.00 is characterized by its medical stainless steel manufacture, offering the essential rigidity to avoid material distortion during removal. Unlike disposable models, this surgical impression tray is autoclavable and must be systematically reprocessed between each patient. Its ergonomic design allows for easy insertion into the mouth while ensuring optimal retention of the molding material. The smooth steel surface facilitates the cleaning of residues after use. It is delivered non-sterile and must strictly follow a complete decontamination protocol before its first use and after each clinical act.

What are the contraindications for use?

The main contraindication mentioned by the manufacturer Helmut Zepf concerns known hypersensitivity or intolerance to metals. Since the instrument is composed of medical stainless steel, contact with the mucosa can trigger an allergic reaction in sensitive patients. If such a hypersensitivity reaction occurs during the procedure, the manufacturer stipulates that the intervention must be immediately stopped and necessary medical measures must be taken. It is therefore crucial to check the patient's allergic history before any manipulation. Furthermore, the use of an instrument showing visible damage, such as cracks or deformations, is prohibited.

What are the maintenance and reprocessing precautions?

Being a non-sterile device upon delivery, this impression tray must be cleaned, disinfected, and sterilized before its first use. The manufacturer Helmut Zepf emphasizes the importance of cleaning each product before use to eliminate any residue. Due to its robust stainless steel design, there is no defined maximum limit of processing cycles, but the user must inspect the instrument before each use to detect any signs of wear, breakage, or defects. Any damaged product must no longer be used. The reprocessing process must follow standard sterilization protocols in force in healthcare facilities to ensure microbiological safety.

Who is the manufacturer and what standards are respected?

The impression tray is manufactured by Helmut Zepf Medizintechnik GmbH, a recognized company located in Seitingen-Oberflacht, Germany. This medical device belongs to Class I (Class Ir according to reprocessing mentions). It meets the regulatory requirements relating to manual dental instruments. Compliance with cleaning and sterilization protocols is the responsibility of the healthcare professional, in accordance with the instructions provided by the manufacturer. As a Class I device, it is designed for professional use in a clinical setting, guaranteeing traceability and manufacturing quality compliant with European standards for reusable surgical instrumentation.


State of the art

Surgical medical consumables play a decisive role in operative safety.

Specifications

Manufacturer Helmut Zepf
Tags