Pinch Retractor for Crowns and 15 cm Bridges - Helmut Zepf (31.182.01) - Delynov
The Pince porte-couronnes et bridges de 15 cm - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.
- Compliance: Medical device Class I.
- Manufacturer: Helmut Zepf Medizintechnik GmbH.
- Reference: 31.182.01.
- Reserved for healthcare professionals. Read instructions carefully before use.
| Manufacturer: Helmut Zepf |
Complete your order
Our customers often order these together
What is the Helmut Zepf crown and bridge forceps?
La pince couronne et bridge de 15 cm, référencée sous le code 31.182.01, est un instrument manuel spécialisé conçu par Helmut Zepf Medizintechnik GmbH. Fabriquée en acier inoxydable de qualité médicale, cette pince est spécifiquement structurée pour assurer une prise stable sur les dispositifs prothétiques. Sa longueur de 15 cm facilite la manipulation dans diverses zones de la cavité orale. En tant qu'instrument de Classe I, elle répond aux exigences de qualité et de sécurité pour une utilisation répétée en chirurgie orale après un cycle complet de nettoyage et de stérilisation.
What are the clinical indications for this instrument?
Cet instrument est indiqué pour toutes les procédures de chirurgie orale restauratrice et de prothèse fixe nécessitant la manipulation de bridges ou de couronnes. Cette pince à bridge est utilisée par le praticien lors des étapes d'essayage pour vérifier l'ajustement marginal et l'occlusion, ainsi que pendant les phases de cimentation définitive ou temporaire. Elle permet de maintenir fermement la prothèse sans altérer ses surfaces, facilitant ainsi son insertion ou son retrait contrôlé. Son utilisation est strictement réservée aux professionnels de santé qualifiés en chirurgie orale.
What are the technical characteristics of the 31.182.01 forceps?
The Helmut Zepf crown forceps has a total length of 15 cm, offering an optimal balance between visibility and gripping force. It is manufactured from high-quality medical stainless steel, ensuring the necessary resistance to thermal and chemical reprocessing cycles. Its ergonomic design allows for precise force transmission to secure prosthetic elements. The manufacturer, Helmut Zepf Medizintechnik GmbH, delivers this product in a non-sterile state, requiring a complete decontamination protocol before the first use and between each patient.
What are the contraindications for the use of these forceps?
The main contraindication identified by the manufacturer Helmut Zepf concerns known hypersensitivity or intolerance to metals, particularly to the medical stainless steel constituting the instrument. If a hypersensitivity reaction is triggered in the patient upon contact, the procedure must be stopped immediately and the necessary medical measures must be taken. It is also forbidden to use the instrument if it shows visible damage such as cracks, breaks, or defects on the edges, as this could compromise the safety of the care or the integrity of the handled prosthesis.
What are the maintenance and reprocessing precautions?
Like any Helmut Zepf manual instrument, these forceps must undergo a complete cycle of cleaning, disinfection, and sterilization before each use. Due to its design and the materials used, there is no defined maximum limit for treatment cycles, as long as the instrument does not show signs of wear or damage. The practitioner must imperatively check for the absence of corrosion or deformation before each use. The products are delivered non-sterile and must be treated according to current hospital protocols. The use of damaged or worn products is strictly prohibited to guarantee clinical safety.
Who is the manufacturer and what standards are respected?
Le dispositif est fabriqué par Helmut Zepf Medizintechnik GmbH, à Seitingen-Oberflacht, Allemagne. Ce fabricant reconnu respecte les standards de fabrication des instruments manuels de chirurgie orale. Le produit est classé comme dispositif médical de Classe I selon la réglementation en vigueur. La traçabilité est assurée par le code de référence 31.182.01. La conformité aux exigences de sécurité est maintenue par un protocole strict de nettoyage et de stérilisation à la charge du praticien, garantissant ainsi la longévité de l'instrument en acier inoxydable médical dans un environnement chirurgical exigeant.
State of the art
Guided bone regeneration (GBR) in implantology relies on membrane fixation quality.