Probe for Depth Measurements - Helmut Zepf (31.691.00) - Delynov

https://www.delynov.fr/web/image/product.template/15955/image_1920?unique=7f79710

The Sonde pour les mesures en profondeur - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.

  • Compliance: Medical device Class I.
  • Manufacturer: Helmut Zepf Medizintechnik GmbH.
  • Reference: 31.691.00.
  • Reserved for healthcare professionals. Read instructions carefully before use.

70.53 € 70.53 EUR 70.53 € Tax Included

70.53 € Tax Included

(70.53 € / Units)
  • Manufacturer

This combination does not exist.

Instrument

What is the Helmut Zepf depth measurement probe?

The Helmut Zepf depth measurement probe, referenced under code 31.691.00, is a precision manual instrument specifically developed for demanding clinical environments. Manufactured from high-quality medical stainless steel by Helmut Zepf Medizintechnik GmbH, this dental depth probe is designed to offer optimal resistance during repeated sterilization cycles. Its thin and graduated structure allows access to narrow areas for direct reading of anatomical or surgical dimensions. As a Class I device, it meets the safety requirements for non-invasive or transiently invasive instruments used in dental offices and operating theaters.

What are the clinical indications for this instrument?

This depth measurement probe is primarily indicated in implant surgery, periodontology, and general oral surgery protocols. It is used to verify the drilling depth of implant sites before implant insertion, thus ensuring compliance with safety distances from sensitive anatomical structures such as the inferior alveolar nerve or the maxillary sinus. In periodontology, it can be used to evaluate attachment loss or the depth of bone defects. Its use is strictly reserved for qualified healthcare professionals mastering surgical measurement techniques in a sterile environment.

What are the technical characteristics of the 31.691.00 probe?

The Helmut Zepf dental depth probe is distinguished by a monobloc design in surgical stainless steel, guaranteeing precise tactile transmission during site exploration. The device is delivered non-sterile and must undergo a complete cleaning, disinfection, and sterilization protocol before its first use and after each clinical act. The manufacturer specifies that due to its robust design and the materials used, there is no defined maximum limit for processing cycles, provided that the instrument shows no visible damage such as cracks or defects on the edges.

What are the contraindications for the use of this probe?

The main contraindication mentioned by the manufacturer Helmut Zepf Medizintechnik GmbH concerns known hypersensitivity or intolerance to metals, particularly medical stainless steel. If an allergic reaction or hypersensitivity reaction is triggered in the patient upon contact with the instrument, the procedure must be stopped immediately. Necessary medical measures must then be taken accordingly. It is therefore recommended to question the patient about their history of metal allergies before any intervention involving this surgical depth probe.

What are the maintenance and reprocessing precautions?

As this Class I medical device is reusable, it requires rigorous reprocessing. Before each use, the practitioner must visually inspect the probe to detect any signs of wear, corrosion, or breakage. It is imperative never to use a damaged product. Cleaning must be meticulous to remove all organic debris before sterilization. Since it is a non-resorbable manual instrument, the accuracy of the measurements depends directly on the integrity of the graduations and the straightness of the shaft. Compatibility with other instruments used simultaneously must also be verified beforehand by the professional.

Who is the manufacturer and what standards are respected?

The device is manufactured by Helmut Zepf Medizintechnik GmbH, a recognized manufacturer located in Seitingen-Oberflacht, Germany. This product is classified as a Class I instrument according to the current regulations on medical devices. The manufacturer imposes strict safety instructions, stipulating that all instruments must be cleaned, disinfected, and sterilized before each use. Compliance with these protocols guarantees patient safety and the longevity of the instrument. The probe is identified under technical reference 31.691.00, ensuring complete traceability within the Helmut Zepf range distributed by Delynov.