Obwegeser Maxillary Retractor - KOCHER-LANGENBECK - Helmut Zepf (38.426.09) - Delynov
The Ecarteur Obwegeser IN - KOCHER-LANGENBECK - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.
- Compliance: Medical device Class I.
- Manufacturer: Helmut Zepf Medizintechnik GmbH.
- Reference: 38.426.09.
- Reserved for healthcare professionals. Read instructions carefully before use.
| Manufacturer: Helmut Zepf |
Complete your order
Our customers often order these together
What is the Obwegeser IN - KOCHER-LANGENBECK Helmut Zepf retractor?
The Obwegeser IN - KOCHER-LANGENBECK retractor, referenced under code 38.426.09, is a manual surgical instrument manufactured by Helmut Zepf Medizintechnik GmbH. Designed in high-quality medical stainless steel, this tool is specifically structured for tissue retraction during invasive procedures. It belongs to the category of reusable Class I consumables. Its robust design allows for precise handling to retract incision edges or maintain mucoperiosteal flaps, thereby providing increased visibility to the practitioner during the surgical act.
What are the clinical indications for this instrument?
Cet instrument est principalement indiqué comme écarteur en chirurgie maxillo-faciale et orale pour maintenir le champ opératoire ouvert. En pratique clinique, il est utilisé par les chirurgiens oraux et les implantologues pour dégager le site chirurgical lors des chirurgies reconstructives, des poses d'implants ou des procédures correctives. Son rôle est crucial pour protéger les tissus environnants tout en stabilisant l'accès aux structures anatomiques profondes. Il peut également servir d'écarteur de langue en fonction de l'angle d'approche et des besoins spécifiques de rétraction tissulaire durant l'intervention.
What are the technical characteristics of the 38.426.09 retractor?
The Helmut Zepf 38.426.09 retractor is distinguished by its medical stainless steel construction, a material chosen for its mechanical resistance and its ability to withstand repeated decontamination cycles. As a Class I device, it meets the safety requirements for non-invasive or surgically invasive instruments for temporary use. The product is delivered non-sterile and requires complete processing before its first use. Its KOCHER-LANGENBECK morphology is optimized to provide an ergonomic grip for assisting staff or the surgeon, ensuring constant tension without excessive slipping on soft tissues.
What are the contraindications for the use of this retractor?
The main medical contraindication documented by the manufacturer Helmut Zepf concerns the patient's known hypersensitivity to metals. Contact of medical stainless steel with tissues can trigger an allergic reaction or intolerance in certain individuals. If such a hypersensitivity reaction occurs during the intervention, the procedure must be immediately stopped and necessary medical measures must be taken. It is therefore imperative to check the patient's allergic history before any use of this metallic instrument in the mouth or at an open surgical site.
What are the maintenance and reprocessing precautions?
Cet instrument réutilisable doit impérativement être nettoyé, désinfecté et stérilisé avant la première utilisation et après chaque utilisation ultérieure. Il n'y a pas de limite maximale définie pour les cycles de traitement, car cela dépend de l'usure réelle du produit. Avant chaque intervention, le praticien doit inspecter l'instrument pour détecter tout dommage visible tel que fissures, cassures ou défauts sur les bords. Tout produit présentant des signes d'usure ou de dégradation doit être immédiatement écarté pour garantir la sécurité du patient et l'efficacité du geste chirurgical.
Who is the manufacturer and what standards are respected?
This instrument is manufactured by Helmut Zepf Medizintechnik GmbH, a recognized company located in Seitingen-Oberflacht, Germany. This medical device is classified as Class I according to current regulations. The manufacturer insists that the use of this retractor is strictly reserved for qualified healthcare professionals. Compliance with cleaning and sterilization protocols is the responsibility of the user, in accordance with the instructions provided by Helmut Zepf to ensure compliance with hospital hygiene and surgical safety standards.
State of the art
Surgical medical consumables play a decisive role in operative safety.



















