Kocher Retractor - Helmut Zepf (38.427.01) - Delynov
The Écarteur Kocher - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.
- Compliance: Medical device Class I.
- Manufacturer: Helmut Zepf Medizintechnik GmbH.
- Reference: 38.427.01.
- Reserved for healthcare professionals. Read instructions carefully before use.
What is the Helmut Zepf Kocher retractor?
The Kocher retractor, referenced under code 38.427.01, is a manual surgical instrument manufactured by Helmut Zepf Medizintechnik GmbH. Designed for oral surgery, this instrument is manufactured from medical stainless steel, a standard material ensuring the rigidity necessary for tissue retraction. As a Class I device, it is part of the arsenal of reusable instruments intended for healthcare professionals. Its structure is specifically designed to allow precise handling during the retraction of soft tissues, thus ensuring clear exposure of the surgical site without obstructing the practitioner's field of vision.
What are the clinical indications for this instrument?
The Kocher retractor is primarily indicated as a manual dental instrument for procedures requiring stable tissue retraction. In implant surgery, it allows flaps to be retracted after incision to facilitate access to the alveolar ridge. In periodontal or general oral surgery, it helps maintain mucosal or periosteal tissues outside the working area, thus securing the passage of rotating or cutting instruments. Its use is strictly reserved for healthcare professionals trained in surgical protocols, ensuring optimal management of soft tissues throughout the duration of the surgical act.
What are the technical characteristics of the 38.427.01 retractor?
This Kocher retractor is distinguished by its manufacture by Helmut Zepf, a manufacturer recognized for its industrial rigor. The instrument is classified as a Class I medical device. It is delivered non-sterile, which requires a complete processing protocol before the first use. Its medical stainless steel design gives it resistance suitable for repeated cleaning and sterilization cycles. Although the manufacturer has not defined a maximum limit for processing cycles due to the robustness of the materials, the user must check for the absence of visible damage, such as cracks or surface defects, before each intervention.
What are the contraindications for the use of this retractor?
The main contraindication related to the use of this Helmut Zepf Kocher retractor is known hypersensitivity or intolerance of the patient to metals, particularly medical stainless steel. If an allergic reaction or hypersensitivity reaction is triggered upon contact with the instrument, the surgical procedure must be immediately interrupted. Necessary medical measures must then be taken accordingly. It is therefore imperative to validate the patient's history regarding metal allergies before any surgical intervention using this manual instrument.
What are the maintenance and reprocessing precautions?
Like all instruments of the Helmut Zepf brand, this retractor must imperatively be cleaned, disinfected, and sterilized before its first use, as well as after each subsequent use. Cleaning is a critical step that must precede sterilization to guarantee the elimination of all biological residues. Before each use, the practitioner must inspect the instrument to detect any visible wear, breakage, or cracks. It is strictly forbidden to use a damaged product. Due to its robust design and the materials used, the number of reprocessing cycles is not limited, subject to maintaining the physical integrity of the instrument.
Who is the manufacturer and what standards are respected?
The device is manufactured by Helmut Zepf Medizintechnik GmbH, located in Seitingen-Oberflacht, Germany. This product belongs to Class I according to medical device regulations. The manufacturer guarantees that the instrument meets the safety requirements for professional use in a surgical environment. Compatibility with other instruments used during the procedure must be verified beforehand by the practitioner. By following the cleaning, disinfection, and sterilization instructions issued by Helmut Zepf, dental surgeons ensure they have a reliable instrument that complies with current medical quality standards.
State of the art
Specialized surgical instrumentation is evolving towards ergonomic designs.
Specifications
| Manufacturer | Helmut Zepf |
| Tags | |
|---|---|
| Tags | |