Tray for the new kit - Helmut Zepf - 47.937.01
The Casier pour le nouveau kit - Helmut Zepf - 47.937.01 is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.
- Compliance: Medical device Class I.
- Manufacturer: Helmut Zepf Medizintechnik GmbH.
- Reserved for healthcare professionals. Read instructions carefully before use.
| Manufacturer: Helmut Zepf |
Complete your order
Our customers often order these together
What is the tray for the new Helmut Zepf 47.937.01 kit?
The tray for the new Helmut Zepf kit, reference 47.937.01, is a Class I device designed by Helmut Zepf Medizintechnik GmbH. This instrument storage tray is manufactured from high-quality medical stainless steel, ensuring compatibility with thermal reprocessing cycles. It is specifically structured to accommodate and organize manual instruments from the brand's new kit. As an instrument storage box, it provides physical protection for the devices while allowing optimal circulation of cleaning and disinfection agents. This product is delivered non-sterile and must undergo a complete preparation cycle before its first use in the practice.
What are the clinical indications for this storage tray?
Ce plateau de chirurgie est indiqué pour l'organisation, le stockage et le retraitement des instruments manuels utilisés en chirurgie orale, parodontologie ou implantologie. Son rôle principal est de servir de support logistique à toutes les étapes de la chaîne de stérilisation. En maintenant chaque instrument en place, il prévient les chocs entre les parties actives, telles que les bords tranchants, prolongeant ainsi la durée de vie de l'équipement. L'utilisation d'une boîte de stérilisation chirurgicale de ce type est recommandée pour standardiser les plateaux techniques et sécuriser la manipulation des instruments souillés par le personnel soignant, limitant ainsi le risque de piqûres accidentelles lors du transfert vers la zone de décontamination.
What are the technical and maintenance characteristics?
Le plateau Helmut Zepf est conçu en acier inoxydable de qualité médicale, un matériau choisi pour sa résistance à la corrosion et sa capacité à supporter des cycles répétés de stérilisation à la vapeur. Tous les composants doivent être nettoyés, désinfectés et stérilisés avant la première utilisation et après chaque utilisation ultérieure. Il est crucial de procéder à une inspection visuelle systématique pour détecter d'éventuels dommages tels que des fissures, des ruptures ou des défauts dans les structures de maintien. Grâce à sa conception robuste et aux matériaux utilisés, il n'y a pas de limite maximale définie pour le nombre de cycles de traitement, tant que l'intégrité physique du plateau est préservée.
What are the contraindications for the use of this device?
The main contraindication related to the use of this tray and associated instruments concerns metal intolerance. Contact with medical stainless steel can trigger a hypersensitivity reaction in certain sensitive patients. If such a reaction occurs during the clinical procedure, the manufacturer Helmut Zepf specifies that the intervention must be immediately stopped and the necessary medical measures must be taken. Although the tray itself is not an invasive instrument, it is in direct contact with the tools that penetrate the tissues, hence the importance of checking the patient's allergic history before any intervention using metallic devices.
What are the precautions for use and safety to be observed?
L'utilisation de ce rangement pour instruments chirurgicaux est strictement réservée aux professionnels de santé qualifiés. Une attention particulière doit être portée au nettoyage préalable : chaque produit doit être parfaitement propre avant d'être stérilisé. Il est interdit d'utiliser des produits présentant une usure visible ou des dommages structurels. La compatibilité avec d'autres produits doit être vérifiée au préalable pour assurer la sécurité du cycle de stérilisation. Les dispositifs étant livrés non stériles, le respect des protocoles de désinfection et de stérilisation validés relève de la responsabilité du praticien afin de prévenir tout risque de contamination croisée entre patients au sein du cabinet de chirurgie orale.
Who is the manufacturer and what standards are respected?
Le fabricant officiel de ce dispositif est Helmut Zepf Medizintechnik GmbH, situé à Seitingen-Oberflacht, en Allemagne. Ce plateau est classé comme dispositif médical de Classe I, répondant aux exigences réglementaires en vigueur pour les instruments manuels de chirurgie orale et leurs accessoires de rangement. La fabrication repose sur une expertise reconnue dans le travail de l'acier inoxydable médical, assurant une durabilité conforme aux attentes des blocs opératoires de chirurgie orale. Le respect des consignes de sécurité émises par Helmut Zepf, notamment concernant le nettoyage et la vérification de l'absence de dommages avant utilisation, est essentiel pour maintenir la conformité du dispositif et garantir la sécurité des soins prodigués.
State of the art
Single-use sterile surgical kits significantly reduce intraoperative contamination.



















