VISPI-SERIES OSTEOTOME INSERT, Helmut Zepf Connection (47.937.05) - Delynov
The INSERT D'OSTÉOTOME À VISPI-SERIES, RACCORD- Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.
- Manufacturer: Helmut Zepf Medizintechnik GmbH.
- Reference: 47.937.05.
- Reserved for healthcare professionals. Read instructions carefully before use.
| Manufacturer: Helmut Zepf |
Complete your order
Our customers often order these together
What is the Helmut Zepf PI-SERIES screw-in osteotome insert?
The PI-SERIES screw-in osteotome insert, referenced under code 47.937.05, is a modular surgical device designed by Helmut Zepf Medizintechnik GmbH. It is an interchangeable osteotome tip that attaches to a specific instrument handle using a screw connection. This modular structure allows practitioners to vary tip shapes without changing the entire set of manual instrumentation. Manufactured according to the quality standards of the Helmut Zepf brand, this component is intended for use under sterile conditions for oral surgery procedures requiring precise manipulation of hard tissues.
What are the clinical indications for this surgical osteotome tip?
This surgical osteotome tip is indicated for various bone and implant surgery procedures. Its primary use involves implant site preparation, particularly during bone condensation techniques in low-density bone (Type III or IV). It is also used for narrow alveolar ridge expansion, allowing for the creation of an adequate implant site while preserving bone capital. In oral surgery, this insert can be used for controlled fragmentation or remodeling of bone structures during pre-implant surgeries. Its design is optimized to provide efficient axial force transmission when using a surgical mallet or through controlled manual pressure.
What are the technical characteristics of the 47.937.05 insert?
L'insert ostéotome Helmut Zepf 47.937.05 se distingue par son système de connexion à vis PI-SERIES, garantissant une stabilité mécanique optimale une fois monté sur son manche. Bien que les dimensions spécifiques de la partie travaillante ne soient pas détaillées, la conception Helmut Zepf repose sur un usinage de haute précision pour assurer une jonction parfaite et sans jeu entre la pointe et le manche. Cette pointe d'ostéotomie est conçue pour résister aux contraintes mécaniques répétées lors des phases d'impact ou de compression. La finition de surface est développée pour faciliter le nettoyage et la décontamination, répondant aux exigences des protocoles de stérilisation en cabinets de chirurgie orale ou en milieux hospitaliers.
What are the contraindications for the use of this osteotomy insert?
Contraindications for the use of this osteotomy insert are related to the general limits of bone surgery and patient specificities. Its use is contraindicated in patients with severe systemic pathologies interfering with bone healing, such as untreated osteoporosis or ongoing head and neck radiotherapy. On a technical level, the use of this instrument is discouraged if the bone density is excessively high (Type I), which could damage the insert or cause harmful thermal heating. It is imperative not to use the insert if the connection thread shows signs of wear or if the tip is blunt, to avoid any risk of instrumental fracture or inappropriate tissue trauma.
What are the maintenance and durability precautions for this non-resorbable instrument?
En tant qu'instrument chirurgical réutilisable et non résorbable, cet insert ostéotome Helmut Zepf exige un protocole d'entretien rigoureux. Après chaque procédure, la pointe doit être dévissée de son manche pour permettre un nettoyage approfondi du pas de vis, zone critique pour l'accumulation de débris biologiques. Il est recommandé d'utiliser des solutions de décontamination enzymatiques non corrosives et de procéder à une stérilisation par autoclave à vapeur selon les cycles validés. Le praticien doit inspecter régulièrement l'état de la pointe et de la connexion vissée. Tout signe de corrosion, de déformation ou de perte de tranchant doit entraîner le remplacement immédiat de l'insert pour maintenir la sécurité et l'efficacité des soins.
Who is the manufacturer and what are the recommendations for use?
L'instrument est fabriqué par Helmut Zepf Medizintechnik GmbH, un fabricant reconnu dans le domaine de l'instrumentation chirurgicale de haute précision. Bien que la classe réglementaire spécifique et le marquage CE ne soient pas mentionnés dans les données sources, les produits Helmut Zepf sont développés pour répondre aux exigences professionnelles des chirurgiens oraux et des implantologues. Il est recommandé de consulter systématiquement la notice d'utilisation fournie pour vérifier les paramètres de retraitement et les compatibilités de montage. L'utilisation de cet insert doit être exclusivement réservée aux praticiens formés aux techniques d'ostéotomie et d'expansion osseuse, assurant ainsi une application clinique conforme aux connaissances scientifiques établies.
State of the art
Surgical medical consumables play a decisive role in operative safety.