Skip to Content

Dental CAD/CAM and Zirconia Flame Polishing Handpiece - Meisinger - (64DCA10104040) - Delynov

https://www.delynov.fr/web/image/product.template/11227/image_1920?unique=2cef985

The X2 polissoirs pour chirurgie orale CAD CAM et zircone flamme lissage DCA10 (pièce à main) - Meisinger - is a medical device manufactured by Hager & Meisinger GmbH.

  • Manufacturer: Hager & Meisinger GmbH.
  • Reference: 64DCA10104040.
  • Reserved for healthcare professionals. Read instructions carefully before use.

16.79 € 16.79 EUR 16.79 €excl. VAT 114.08 €

16.79 €excl. VAT 114.08 €

In stock
(16.79 € / Units)
  • Manufacturer

This combination does not exist.

Instrument
Manufacturer: Meisinger

Qu'est-ce que le polisseur de zircone et CAD CAM DCA10 pour la chirurgie orale ?

Le dispositif de polissage pour CAO/FAO et lissage de flammes en zircone X2 DCA10 est un instrument rotatif de la marque Meisinger, spécifiquement développé pour la finition des matériaux prothétiques modernes. Ce modèle se présente sous une forme de flamme, une géométrie particulièrement adaptée au travail sur des surfaces anatomiques complexes. Conçus pour être montés sur une pièce à main, ces polissoirs permettent l'affinage de l'état de surface des restaurations après usinage ou ajustements structurels. Hager & Meisinger GmbH offre ici une solution technique ciblée pour les laboratoires et les praticiens exerçant la chirurgie orale numérique, garantissant la compatibilité avec les exigences de dureté de la zircone.

What are the clinical indications for this Meisinger polisher?

Ce polisseur en zircone est indiqué pour les étapes de lissage et de pré-polissage des dispositifs prothétiques fixes. Son utilisation est privilégiée lors de la finition des couronnes, bridges ou inlays-onlays conçus par technologie CAD CAM. En chirurgie orale prothétique et en restaurations, l'utilisation de la référence 64DCA10104040 permet l'élimination des micro-striations d'usinage et la régularisation de la surface du matériau avant le polissage final ou le glaçage. La forme flamme facilite l'accès aux zones de transition et aux pentes cuspidiennes, assurant une continuité de surface essentielle pour limiter l'accumulation de plaque bactérienne et optimiser l'intégration biologique de la restauration.

What are the technical characteristics of the DCA10 model?

The product referenced under code 64DCA10104040 by Meisinger features precise specifications for handpiece work. Its flame shape (DCA10) is optimized for smoothing high-resistance materials such as zirconia. Unlike standard polishers, its composition is adapted to the thermal and mechanical stresses associated with CAD CAM materials. The shank is dimensioned for stable insertion into the handpiece chuck, ensuring centered rotation without excessive vibrations. This packaging of two units allows for efficient stock management for prosthetic finishing procedures requiring constant grit regularity when handling polycrystalline ceramics.

What are the contraindications for the use of these polishers?

Although no specific medical contraindications are listed in the technical data, the use of these instruments must comply with the rotation speed protocols recommended by Hager & Meisinger GmbH. Use at excessive speed could lead to localized heating of the zirconia material, risking alteration of its mechanical properties or causing micro-cracks. These polishers must not be used on materials for which they are not intended, such as soft resins or certain non-precious metals, at the risk of premature clogging of the instrument or a non-compliant surface result. The integrity of the shank should be checked before any rotation.

What are the maintenance and handling precautions?

Pour préserver l'efficacité du polisseur CAD CAM Meisinger, il est recommandé de suivre les cycles de nettoyage et de stérilisation conformément aux instructions d'utilisation des instruments rotatifs. La manipulation doit s'effectuer avec une pression modérée pour éviter une usure asymétrique de la tête en forme de flamme. Ces instruments étant destinés à être utilisés sur une pièce à main, le praticien doit s'assurer que l'axe de l'instrument est correctement verrouillé avant activation. Une inspection visuelle régulière de l'état de surface du polisseur est nécessaire : tout signe de désalignement ou de perte de pouvoir abrasif exige le remplacement de l'outil pour garantir la sécurité du patient et la qualité du lissage.

Who is the manufacturer and what standards are respected?

Ce dispositif est officiellement fabriqué par Hager & Meisinger GmbH, une entreprise reconnue dans le domaine de l'instrumentation rotative médicale. Ce produit, identifié par la référence technique 64DCA10104040, est conçu selon les standards de fabrication allemands pour les dispositifs de la catégorie CONSO. Bien que la classe réglementaire spécifique et le marquage CE ne soient pas détaillés dans la fiche technique actuelle, les produits Meisinger sont développés pour répondre aux exigences professionnelles des chirurgiens oraux et des prosthodontistes. Pour toute information précise sur les certificats de conformité ou les normes ISO appliquées à ce lot de polissoirs, il est impératif de se référer à l'étiquetage original et aux instructions d'utilisation fournies.


State of the art

Surgical medical consumables play a decisive role in operative safety.

Delivery

From France to the whole world.

Europe, overseas territories, worldwide. Everything ships through our own logistics.

With you tomorrow

Ordered before 2 pm, delivered within 24 h. Otherwise, within 72 h.

Delivery included from €500 incl. VAT

Offer limited to mainland France.

A team that answers

Orders, traceability, materiovigilance, your dedicated contact in Épinal. Parcels prepared by the ESAT of Dinozé.

We’ll call you back

References

They trust us.

Public and private healthcare institutions order from Delynov.