Master Pin's Basic BMPBA - Dr. Istvan Urban - Meisinger - Hager & Meisinger GmbH (79BMPBA) - Delynov
Product features
The Master Pin's Basic BMPBA - Dr. Istvan Urban - Meisinger - Hager & Meisinger GmbH is a medical device manufactured by Hager & Meisinger GmbH — Class IIb, CE marking CE0044.
- Compliance: Medical device Class IIb, CE marking CE0044.
- Manufacturer: Hager & Meisinger GmbH.
- Reference: 79BMPBA.
- Reserved for healthcare professionals. Read instructions carefully before use.
fabricant :
Hager & Meisinger GmbH
Hansemannstr. 10
41468 Neuss
Germany .
Indications d’utilisation Les systèmes Bone Management® Master-Pin-Control sont indiqués pour la fixation des extrémités de la membrane apicale au niveau de l’os local, afin d’empêcher toute micromobilité de la membrane. Ces systèmes permettent la fixation de membranes résorbables, de membranes non résorbables et de membranes renforcées au titane. Les vitesses conseillées pour l’application, de même que les vitesses maximales, sont récapitulées dans la vue d’ensemble des instruments, au chapitre « Contenu ». Pour garantir une utilisation correcte et en toute sécurité, ces vitesses doivent être respectées. Les instruments et les punaises sont fournis non stériles, ce qui fait qu’ils doivent être nettoyés, désinfectés et stérilisés avant d’être utilisés. Pour un traitement correct des articles, veuillez vous reporter aux instructions de traitement (nettoyage, désinfection et stérilisation) des dispositifs médicaux produits par la Société Hager & Meisinger GmbH. Contre-indications Globalement, les contre-indications médicales générales, de même que les contre-indications locales, absolues et relatives s’appliquant aux processus de chirurgie dentaire, doivent être respectées. Contre-indications absolues Croissance dento-alvéolaire non achevée (exception : cas dans lesquels une croissance dento-alvéolaire ne peut pas être escomptée, p. ex. dysplasie ectodermique) Infection aiguë dans ou près du site de fixation, de même que processus pathologiques (p. ex. symptômes tels que fièvre, inflammation locale, abcès) Qualité et/ou quantité osseuse insuffisante. Contre-indications relatives Allergies connues et/ou réaction de corps étrangers au matériau d’implant Troubles systémiques Maladies affectant le métabolisme osseux Traitements médicaux conduisant à une détérioration progressive de l’os (p. ex. cortisone, immunosuppresseurs) Abus de drogues et d’alcool Manque de coopération du patient Mauvaise circulation Travail physique dur ou sports actifs État mental pouvant conduire à ne pas respecter les prescriptions médicales Mâchoire fortement atrophique réservé aux professionnels de santé
What is the Meisinger Master Pin's Basic BMPBA?
The Master Pin's Basic BMPBA, identified under reference 79BMPBA, is a specialized bone management system developed by Meisinger in collaboration with Dr. Istvan Urban. This medical device is designed to ensure the precise fixation of apical membrane ends to the local bone during guided bone regeneration (GBR) procedures. Its structure and components allow for the effective stabilization of protective barriers to promote optimal healing. This system is an essential tool for practitioners seeking a reliable solution to maintain the integrity of the regeneration space in oral surgery.
What are the clinical indications for the Master-Pin-Control system?
The Master-Pin-Control system from Hager & Meisinger GmbH is specifically indicated for fixing membranes to the local bone to prevent any micromobility of the latter. Membrane stability is a critical factor for the success of grafting procedures. This device is versatile, allowing for the fixation of resorbable membranes, non-resorbable membranes, as well as titanium-reinforced membranes. It is used in implant surgery and bone reconstruction protocols where strict immobilization of the barrier is required to protect the graft during the consolidation phase.
What are the technical characteristics of the Master Pin's Basic?
The Master Pin's Basic BMPBA (reference 79BMPBA) is a Class IIb device certified CE0044. The system includes instruments and pins designed for precise insertion into the bone. A major technical feature lies in following the rotation speeds recommended by the manufacturer Meisinger for the application of the instruments, as detailed in the content overview. These specifications ensure correct and safe use. It is important to note that the instruments and pins are supplied non-sterile, requiring a full cycle of cleaning, disinfection, and sterilization before each use according to Hager & Meisinger GmbH protocols.
What are the contraindications for the use of this device?
The use of the Master-Pin-Control system presents several absolute and relative contraindications. Absolute contraindications include incomplete dento-alveolar growth (except in specific cases such as ectodermal dysplasia), acute infection or a pathological process near the fixation site (fever, inflammation, abscess), as well as insufficient bone quality or quantity. Relative contraindications concern known allergies or foreign body reactions related to the implant material, systemic disorders, diseases affecting bone metabolism, or medical treatments leading to progressive bone deterioration, such as prolonged use of cortisone or immunosuppressants.
What are the precautions for use and processing of the instruments?
To ensure patient safety and the longevity of the equipment, Meisinger instruments and pins must imperatively be processed before use. The process includes cleaning, disinfection, and sterilization in accordance with the instructions provided by Hager & Meisinger GmbH. During surgery, the practitioner must ensure that the maximum indicated speeds are respected to avoid bone overheating or damage to the instruments. Preventing membrane micromobility is the primary objective; therefore, the positioning of the pins must be rigorous to ensure stable apical fixation, whether the membrane is resorbable or non-resorbable.
Who is the manufacturer and what standards are met?
The Master Pin's Basic BMPBA is manufactured by Hager & Meisinger GmbH, a company based in Neuss, Germany. This medical device carries the CE0044 marking and belongs to Class IIb, thus meeting strict regulatory requirements for implantable and surgical devices. The manufacturer provides precise guidelines for the processing of medical devices to ensure use in compliance with European safety standards. By choosing this system distributed by Delynov, healthcare professionals ensure they are using high-precision equipment validated by the clinical expertise of Dr. Istvan Urban and the industrial know-how of Meisinger.
State of the art
Guided bone regeneration (GBR) in implantology relies on membrane fixation quality.
Specifications
| Manufacturer | Meisinger |
| Tags | |
|---|---|
| Tags | |