Skip to Content

Basic micro-screw system - Dr. Fouad Khoury - Meisinger - Hager & Meisinger GmbH (79BMSBA) - Delynov

https://www.delynov.fr/web/image/product.template/79641/image_1920?unique=e9f880c

The Système de micro-vis basique - Dr. Fouad Khoury - Meisinger - Hager & Meisinger GmbH is a medical device manufactured by Hager & Meisinger GmbH, Class IIb, CE marking CE0044.

  • Compliance: Medical device Class IIb, CE marking CE0044.
  • Manufacturer: Hager & Meisinger GmbH.
  • Reference: 79BMSBA.
  • Reserved for healthcare professionals. Read instructions carefully before use.

1,056.00 € 1056.0 EUR 1,056.00 €excl. VAT

1,056.00 €excl. VAT

(0.00 € / Units)
  • Manufacturer

This combination does not exist.

GBR
Manufacturer: Meisinger

What is the Meisinger basic micro-screw system (79BMSBA)?

The basic micro-screw system, developed in collaboration with Dr. Fouad Khoury and manufactured by Meisinger, is a specialized device for guided bone regeneration (GBR). This kit primarily consists of osteosynthesis screws designed in surgical stainless steel. This specific material was selected to offer optimal mechanical stability despite extremely reduced diameters of 1.0 mm and 1.2 mm. This Khoury micro-screw system allows practitioners to handle bone transplants with great precision, guaranteeing the rigid maintenance necessary for the initial bone healing phase. It is a robust technical solution for block graft management in the maxillofacial sector.

What are the clinical indications for this GBR micro-screw system?

Le système de micro-vis chirurgicales de la gamme Bone Management® est spécifiquement indiqué pour la fixation et la stabilisation sécurisées des greffons osseux corticaux. Son application principale concerne le traitement des fractures osseuses et, plus fréquemment en cabinet, la fixation de blocs osseux prélevés et transplantés lors des processus d'augmentation dans la cavité orale. Ces interventions visent à restaurer le volume osseux dans la zone maxillo-mandibulaire avant ou pendant la pose d'implants. L'utilisation de ce système de micro-vis assure une immobilisation stricte du greffon, condition sine qua non pour une intégration osseuse réussie et une revascularisation optimale du transplant cortical.

What are the technical characteristics of the included screws?

Les caractéristiques techniques de ce système de micro-vis pour chirurgie orale reposent sur la finesse et la résistance de ses composants. Les vis d'ostéosynthèse sont disponibles en deux diamètres distincts : 1,0 mm et 1,2 mm. Elles sont fabriquées à partir d'un acier inoxydable de grade chirurgical qui confère une haute résistance à la torsion et à la rupture, permettant leur insertion même dans des sites à forte densité osseuse. En tant que dispositif de Classe IIb, ce système répond à des exigences de sécurité strictes. Pour garantir une utilisation correcte, le praticien doit respecter les vitesses de rotation recommandées par Meisinger dans l'aperçu des instruments fourni avec le kit.

What are the contraindications for the use of this osteosynthesis kit?

The use of the Meisinger basic micro-screw system is subject to compliance with general and local medical contraindications related to oral surgery. Absolute contraindications include the presence of active infections in the augmentation area or its immediate periphery. Similarly, any uncontrolled local or systemic pathological process, such as fever, local inflammation, or abscesses, proscribes the intervention. Finally, insufficient bone volume, whether in terms of quality or quantity to ensure screw anchorage, constitutes a major contraindication. The practitioner must rigorously evaluate the physiological terrain before any implementation of the osteosynthesis protocol.

What are the precautions related to the removal of micro-screws?

Unlike permanent implants, the micro-screws of this system are not intended to remain indefinitely in the patient's body. Once the support and stabilization function is fulfilled (typically after complete healing of the bone transplant or consolidation of a fracture), the screws must be entirely removed. This removal generally occurs during the surgical reentry phase for implant placement. Prolonged maintenance beyond the healing phase is not recommended by the manufacturer Hager & Meisinger GmbH. The practitioner must therefore plan this removal step in their overall bone reconstruction treatment plan.

Who is the manufacturer and what standards are respected?

Le système de micro-vis basique (référence 79BMSBA) est fabriqué par Hager & Meisinger GmbH, une entreprise reconnue située à Neuss, en Allemagne. Ce dispositif médical est certifié selon les normes européennes en vigueur, affichant un marquage CE0044. Il appartient à la Classe réglementaire IIb, ce qui garantit un haut niveau de contrôle qualité et de sécurité pour les interventions de chirurgie orale invasive. En choisissant les produits Meisinger distribués par Delynov, les praticiens en chirurgie orale et en implantologie s'assurent d'utiliser des instruments conformes aux exigences du Règlement Européen relatif aux Dispositifs Médicaux, spécifiquement conçus pour les protocoles exigeants de la technique de Khoury.


State of the art

Guided bone regeneration (GBR) in implantology relies on membrane fixation quality.

Delivery

From France to the whole world.

Europe, overseas territories, worldwide. Everything ships through our own logistics.

With you tomorrow

Ordered before 2 pm, delivered within 24 h. Otherwise, within 72 h.

Delivery included from €500 incl. VAT

Offer limited to mainland France.

A team that answers

Orders, traceability, materiovigilance, your dedicated contact in Épinal. Parcels prepared by the ESAT of Dinozé.

We’ll call you back

References

They trust us.

Public and private healthcare institutions order from Delynov.