Norm Tray - Non-Perforated Lid - Helmut Zepf (85.142.20) - Delynov
The Norm Tray - Couvercle Non-Perforé - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.
- Compliance: Medical device Class I.
- Manufacturer: Helmut Zepf Medizintechnik GmbH.
- Reference: 85.142.20.
- Reserved for healthcare professionals. Read instructions carefully before use.
| Manufacturer: Helmut Zepf |
Complete your order
Our customers often order these together
What is the Norm Tray - Non-Perforated Lid - Helmut Zepf?
Le Norm Tray (référence 85.142.20) est un accessoire de gestion de l'instrumentation conçu par Helmut Zepf. C'est un couvercle non perforé destiné à recouvrir les plateaux ou cassettes de chirurgie. Fabriqué en acier inoxydable de qualité médicale, ce composant permet de fermer hermétiquement par le dessus le plateau d'examen de chirurgie orale, offrant une protection physique aux instruments manuels. Sa structure solide, sans perforations, est spécifiquement conçue pour les protocoles où une séparation stricte de l'environnement externe est requise avant ou après les phases de traitement, assurant ainsi une organisation rigoureuse du plateau technique dans les cabinets de chirurgie orale ou d'implantologie.
What are the clinical indications?
Ce couvercle de cassette d'instrumentation est indiqué pour la protection et la gestion des instruments manuels lors des procédures de chirurgie orale, d'implantologie et de parodontologie. Il est utilisé pour couvrir le plateau de norme chirurgicale afin de maintenir l'intégrité des jeux d'instruments pendant le transport entre la zone de décontamination et le fauteuil, ou pendant le stockage post-stérilisation. Faisant partie du système de plateau d'examen chirurgical, il facilite le maintien d'un environnement de travail ordonné et sécurisé, limitant le risque de chutes ou de contact accidentel avec des instruments tranchants ou pointus avant leur utilisation clinique par le praticien.
What are the technical characteristics?
The Helmut Zepf lid, bearing technical reference 85.142.20, is distinguished by its non-perforated design. Unlike filtering models, this solid version ensures total coverage of the surgery cassette. It is designed in high-quality medical stainless steel, a material chosen for its resistance to repeated cleaning and disinfection cycles. This device belongs to Class I according to medical device regulations. It is delivered non-sterile and must undergo a complete cycle of cleaning, disinfection, and sterilization before its first use and between each patient, in accordance with current hospital hygiene protocols.
What are the contraindications for use?
The main contraindication related to the use of this medical stainless steel device is known hypersensitivity or intolerance to metals in the patient. Although the lid is not an invasive instrument, any direct or indirect contact can trigger an allergic reaction in sensitive subjects. The manufacturer Helmut Zepf specifies that if such a hypersensitivity reaction occurs during the procedure, it must be immediately interrupted and necessary medical measures must be taken. Furthermore, it is strictly contraindicated to use the product if it shows visible damage such as cracks, breaks, or structural deformations compromising its protective function.
What are the maintenance and reprocessing precautions?
Due to its stainless steel composition and robust design, there is no defined maximum limit of treatment cycles for this surgery cassette lid, as long as its physical integrity is preserved. Before each use, the practitioner must visually inspect the device to detect any trace of wear or corrosion. The reprocessing process must include thorough cleaning, disinfection, and sterilization. It is crucial to verify compatibility with other cleaning products and solutions used in the sterilization chain. The use of damaged products or those with defects on the edges is strictly prohibited to guarantee the aseptic safety of the tray.
Who is the manufacturer and what standards are respected?
Ce dispositif est fabriqué par Helmut Zepf Medizintechnik GmbH, un fabricant reconnu situé à Seitingen-Oberflacht, en Allemagne. Le couvercle Norm Tray est classé comme dispositif médical de Classe I (Classe Ir selon certaines nomenclatures de retraitement). Il répond aux exigences réglementaires pour les instruments manuels de chirurgie orale. Ces produits doivent être manipulés exclusivement par des professionnels de santé qualifiés. La traçabilité et la qualité de fabrication de Helmut Zepf garantissent que ce couvercle répond aux standards nécessaires pour une utilisation intensive en environnement chirurgical, sous réserve du strict respect des instructions de nettoyage et de stérilisation figurant dans le manuel technique.
State of the art
Surgical medical consumables play a decisive role in operative safety.



















