Skip to Content
The Delynov team is away and back on 24 August. Your parcels will be processed with longer lead times.

Storage cassette - Helmut ZEPF (85.995.20) - Delynov

https://www.delynov.fr/web/image/product.template/150503/image_1920?unique=547e5ef

The Cassette de rangement - Helmut ZEPF is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.

  • Compliance: Medical device Class I.
  • Manufacturer: Helmut Zepf Medizintechnik GmbH.
  • Reference: 85.995.20.
  • Reserved for healthcare professionals. Read instructions carefully before use.

285.01 € 285.01 EUR 285.01 € Tax Included 558.55 €

285.01 € Tax Included 558.55 €

(0.00 € / Units)
  • Manufacturer

This combination does not exist.

Instrument

What is the Helmut Zepf storage cassette (85.995.20)?

The Helmut Zepf storage cassette, reference 85.995.20, is a Class I medical device designed specifically for the organization and protection of surgical equipment. Manufactured in medical stainless steel by Helmut Zepf Medizintechnik GmbH, this surgical storage cassette is intended to hold instruments, often in the form of complete sets, in order to secure their handling during the critical phases of the product life cycle. This stainless steel sterilization box serves as a structural support to hold instruments during reprocessing, thus avoiding direct shocks and potential damage to active parts, while guaranteeing orderly storage after sterilization.

What are the clinical indications for this device?

According to the specifications of the manufacturer Helmut Zepf, this product is indicated for storing surgical instruments, whether they are organized in sets or individually. Its use is mainly dedicated to reprocessing phases, including cleaning, disinfection, and sterilization, as well as subsequent storage in a sterile or non-sterile environment. In oral and implant surgery, the use of this surgical instrument storage box allows for rigorous management of technical trays, ensuring that each instrument required for a specific procedure remains grouped and protected from any contamination or physical degradation before its use at the chairside.

What are the technical characteristics of the 85.995.20 cassette?

The Helmut Zepf storage cassette (85.995.20) is made of medical grade stainless steel, a material chosen for its resistance to repeated cleaning and sterilization cycles. This surgical sterilization box is designed to withstand the thermal and chemical stresses of standardized disinfection protocols. The manufacturer specifies that due to the product design and the materials used, there is no defined maximum limit for the number of processing cycles achievable, although the user must systematically check for the absence of visible damage such as cracks or defects on the edges before each use. This device is strictly reserved for healthcare professionals.

What are the contraindications for the use of this equipment?

The main contraindication related to the use of this stainless steel cassette concerns hypersensitivity reactions. Although direct contact with the patient is limited, metal intolerance can cause allergic reactions if contact occurs with the stored instrument. If such a hypersensitivity reaction is triggered, the clinical procedure must be immediately stopped and the necessary medical measures must be taken. Furthermore, it is formally contraindicated to use the product if it shows visible damage or wear, such as cracks, breaks, or structural defects, in order to guarantee the safety of personnel and the integrity of the contained instruments.

What are the maintenance and reprocessing precautions?

All products delivered by Helmut Zepf Medizintechnik GmbH are supplied non-sterile. It is imperative to clean, disinfect, and sterilize the cassette before its first use, as well as before each subsequent reuse. The reprocessing process must be complete and rigorous. Before each cycle, a visual inspection is necessary to detect any sign of wear. The use of damaged products is strictly prohibited. Compatibility with other devices must also be verified beforehand. As this is a non-resorbable steel device, durability depends directly on compliance with the cleaning protocols recommended by the manufacturer to avoid any corrosion or degradation of the material.

Who is the manufacturer and what standards are respected?

This device is manufactured by Helmut Zepf Medizintechnik GmbH, located in Seitingen-Oberflacht, Germany. It is a Class I medical device, compliant with regulatory requirements for the storage and reprocessing of surgical instruments. The manufacturer emphasizes that the product is reserved for professional use by qualified practitioners. As a recognized manufacturer, Helmut Zepf guarantees the use of medical stainless steel meeting safety standards for surgical applications. Compliance with safety instructions, particularly systematic cleaning before use, is essential to maintain the device's conformity during its integration into the dental practice's sterilization chain.


State of the art

Surgical medical consumables play a decisive role in operative safety.

Specifications

Manufacturer Helmut Zepf
Tags
Tags
Instrument